Abstract: This paper aims at bringing a scientific contribution to the cardiac arrhythmia biomedical diagnosis systems; more precisely to the study of the amelioration of cardiac arrhythmia classification performance using artificial neural network, adaptive neuro-fuzzy and fuzzy inference systems classifiers. The purpose of this amelioration is to enable cardiologists to make reliable diagnosis through automatic cardiac arrhythmia analyzes and classifications based on high confidence classifiers. In this study, six classes of the most commonly encountered arrhythmias are considered: the Right Bundle Branch Block, the Left Bundle Branch Block, the Ventricular Extrasystole, the Auricular Extrasystole, the Atrial Fibrillation and the Normal Cardiac rate beat. From the electrocardiogram (ECG) extracted parameters, we constructed a matrix (360x360) serving as an input data sample for the classifiers based on neural networks and a matrix (1x6) for the classifier based on fuzzy logic. By varying three parameters (the quality of the neural network learning, the data size and the quality of the input parameters) the automatic classification permitted us to obtain the following performances: in terms of correct classification rate, 83.6% was obtained using the fuzzy logic based classifier, 99.7% using the neural network based classifier and 99.8% for the adaptive neuro-fuzzy based classifier. These results are based on signals containing at least 360 cardiac cycles. Based on the comparative analysis of the aforementioned three arrhythmia classifiers, the classifiers based on neural networks exhibit a better performance.
Abstract: This paper describes a new supervised fusion (hybrid)
electrocardiogram (ECG) classification solution consisting of a new
QRS complex geometrical feature extraction as well as a new version
of the learning vector quantization (LVQ) classification algorithm
aimed for overcoming the stability-plasticity dilemma. Toward this
objective, after detection and delineation of the major events of ECG
signal via an appropriate algorithm, each QRS region and also its
corresponding discrete wavelet transform (DWT) are supposed as
virtual images and each of them is divided into eight polar sectors.
Then, the curve length of each excerpted segment is calculated
and is used as the element of the feature space. To increase the
robustness of the proposed classification algorithm versus noise,
artifacts and arrhythmic outliers, a fusion structure consisting of
five different classifiers namely as Support Vector Machine (SVM),
Modified Learning Vector Quantization (MLVQ) and three Multi
Layer Perceptron-Back Propagation (MLP–BP) neural networks with
different topologies were designed and implemented. The new proposed
algorithm was applied to all 48 MIT–BIH Arrhythmia Database
records (within–record analysis) and the discrimination power of the
classifier in isolation of different beat types of each record was
assessed and as the result, the average accuracy value Acc=98.51%
was obtained. Also, the proposed method was applied to 6 number
of arrhythmias (Normal, LBBB, RBBB, PVC, APB, PB) belonging
to 20 different records of the aforementioned database (between–
record analysis) and the average value of Acc=95.6% was achieved.
To evaluate performance quality of the new proposed hybrid learning
machine, the obtained results were compared with similar peer–
reviewed studies in this area.