Abstract: Utilities use operating reserve for frequency regulation.To ensure that the operating frequency and system security are well maintained, the operating grid codes always specify that the reserve quantity and response rate should meet some prescribed levels. This paper proposes a methodology to evaluate system's contingency reserve for an isolated power network. With the presented algorithm to estimate system's frequency response characteristic, an online allocation of contingency reserve would be feasible to meet the grid codes for contingency operation. Test results from the simulated conditions, and from the actual operating data verify the merits of the proposed methodology to system's frequency control, and security.
Abstract: Chatter vibration has been a troublesome problem for a
machine tool toward the high precision and high speed machining.
Essentially, the machining performance is determined by the dynamic
characteristics of the machine tool structure and dynamics of cutting
process. Therefore the dynamic vibration behavior of spindle tool
system greatly determines the performance of machine tool. The
purpose of this study is to investigate the influences of the machine
frame structure on the dynamic frequency of spindle tool unit through
finite element modeling approach. To this end, a realistic finite
element model of the vertical milling system was created by
incorporated the spindle-bearing model into the spindle head stock of
the machine frame. Using this model, the dynamic characteristics of
the milling machines with different structural designs of spindle head
stock and identical spindle tool unit were demonstrated. The results of
the finite element modeling reveal that the spindle tool unit behaves
more compliant when the excited frequency approaches the natural
mode of the spindle tool; while the spindle tool show a higher dynamic
stiffness at lower frequency that may be initiated by the structural
mode of milling head. Under this condition, it is concluded that the
structural configuration of spindle head stock associated with the
vertical column of milling machine plays an important role in
determining the machining dynamics of the spindle unit.
Abstract: This paper deals with a novel approach of power
transformers diagnostics. This approach identifies the exact location
and the range of a fault in the transformer and helps to reduce
operation costs related to handling of the faulty transformer, its
disassembly and repair. The advantage of the approach is a
possibility to simulate healthy transformer and also all faults, which
can occur in transformer during its operation without its
disassembling, which is very expensive in practice. The approach is
based on creating frequency dependent impedance of the transformer
by sweep frequency response analysis measurements and by 3D FE
parametrical modeling of the fault in the transformer. The parameters
of the 3D FE model are the position and the range of the axial short
circuit. Then, by comparing the frequency dependent impedances of
the parametrical models with the measured ones, the location and the
range of the fault is identified. The approach was tested on a real
transformer and showed high coincidence between the real fault and
the simulated one.
Abstract: In the last few years, three multivariate spectral
analysis techniques namely, Principal Component Analysis (PCA),
Independent Component Analysis (ICA) and Non-negative Matrix
Factorization (NMF) have emerged as effective tools for oscillation
detection and isolation. While the first method is used in determining
the number of oscillatory sources, the latter two methods
are used to identify source signatures by formulating the detection
problem as a source identification problem in the spectral domain.
In this paper, we present a critical drawback of the underlying linear
(mixing) model which strongly limits the ability of the associated
source separation methods to determine the number of sources
and/or identify the physical source signatures. It is shown that the
assumed mixing model is only valid if each unit of the process gives
equal weighting (all-pass filter) to all oscillatory components in its
inputs. This is in contrast to the fact that each unit, in general, acts
as a filter with non-uniform frequency response. Thus, the model
can only facilitate correct identification of a source with a single
frequency component, which is again unrealistic. To overcome
this deficiency, an iterative post-processing algorithm that correctly
identifies the physical source(s) is developed. An additional issue
with the existing methods is that they lack a procedure to pre-screen
non-oscillatory/noisy measurements which obscure the identification
of oscillatory sources. In this regard, a pre-screening procedure
is prescribed based on the notion of sparseness index to eliminate
the noisy and non-oscillatory measurements from the data set used
for analysis.