Abstract: This paper presents the H-ARQ techniques comparison for OFDM systems with a new family of non-binary LDPC codes which has been developed within the EU FP7 DAVINCI project. The punctured NB-LDPC codes have been used in a simulated model of the transmission system. The link level performance has been evaluated in terms of spectral efficiency, codeword error rate and average number of retransmissions. The NB-LDPC codes can be easily and effective implemented with different methods of the retransmission needed if correct decoding of a codeword failed. Here the Optimal Symbol Selection method is proposed as a Chase Combining technique.
Abstract: This paper presents the impact study of GTO Controlled Series Capacitor (GCSC) parameters on measured impedance (Zseen) by MHO distance relays for single transmission line high voltage 220 kV in the presence of single phase to earth fault with fault resistance (RF). The study deals with a 220 kV single electrical transmission line of Eastern Algerian transmission networks at Group Sonelgaz (Algerian Company of Electrical and Gas) compensated by series Flexible AC Transmission System (FACTS) i.e. GCSC connected at midpoint of the transmission line. The transmitted active and reactive powers are controlled by three GCSC-s. The effects of maximum reactive power injected as well as injected maximum voltage by GCSC on distance relays measured impedance is treated. The simulations results investigate the effects of GCSC injected parameters: variable reactance (XGCSC), variable voltage (VGCSC) and reactive power injected (QGCSC) on measured resistance and reactance in the presence of earth fault with resistance fault varied between 5 to 50 Ω for three cases study.
Abstract: Since large power transformers are the most
expensive and strategically important components of any power
generator and transmission system, their reliability is crucially
important for the energy system operation. Also, Circuit breakers are
very important elements in the power transmission line so monitoring
the events gives a knowledgebase to determine time to the next
maintenance. This paper deals with the introduction of the
comparative method of the state estimation of transformers and
Circuit breakers using continuous monitoring of voltage, current.
This paper gives details a new method based on wavelet to apparatus
insulation monitoring. In this paper to insulation monitoring of
transformer, a new method based on wavelet transformation and
neutral point analysis is proposed. Using the EMTP tools, fault in
transformer winding and the detailed transformer winding model
were simulated. The current of neutral point of winding was analyzed
by wavelet transformation. It is shown that the neutral current of the
transformer winding has useful information about fault in insulation
of the transformer.
Abstract: This study describes analysis of tower grounding
resistance effected the back flashover voltage across insulator string
in a transmission system. This paper studies the 500 kV transmission
lines from Mae Moh, Lampang to Nong Chok, Bangkok, Thailand,
which is double circuit in the same steel tower with two overhead
ground wires. The factor of this study includes magnitude of
lightning stroke, and front time of lightning stroke. Steel tower uses
multistory tower model. The assumption of studies based on the
return stroke current ranged 1-200 kA, front time of lightning stroke
between 1 μs to 3 μs. The simulations study the effect of varying
tower grounding resistance that affect the lightning current.
Simulation results are analyzed lightning over voltage that causes
back flashover at insulator strings. This study helps to know causes
of problems of back flashover the transmission line system, and also
be as a guideline solving the problem for 500 kV transmission line
systems, as well.
Abstract: This paper presents a video transmission system using
layered multiple description (coding (MDC) and multi-path transport
for reliable video communications in wireless ad-hoc networks.
The proposed MDC extends a quality-scalable H.264/AVC video
coding algorithm to generate two independent descriptions. The two
descriptions are transmitted over different paths to a receiver in order
to alleviate the effect of unstable channel conditions of wireless adhoc
networks. If one description is lost due to transmission erros,
then the correctly received description is used to estimate the lost
information of the corrupted description. The proposed MD coder
maintains an adequate video quality as long as both description are
not simultaneously lost. Simulation results show that the proposed
MD coding combined with multi-path transport system is largely
immune to packet losses, and therefore, can be a promising solution
for robust video communications over wireless ad-hoc networks.
Abstract: Directional over current relays (DOCR) are commonly used in power system protection as a primary protection in distribution and sub-transmission electrical systems and as a secondary protection in transmission systems. Coordination of protective relays is necessary to obtain selective tripping. In this paper, an approach for efficiency reduction of DOCRs nonlinear optimum coordination (OC) is proposed. This was achieved by modifying the objective function and relaxing several constraints depending on the four constraints classification, non-valid, redundant, pre-obtained and valid constraints. According to this classification, the far end fault effect on the objective function and constraints, and in consequently on relay operating time, was studied. The study was carried out, firstly by taking into account the near-end and far-end faults in DOCRs coordination problem formulation; and then faults very close to the primary relays (nearend faults). The optimal coordination (OC) was achieved by simultaneously optimizing all variables (TDS and Ip) in nonlinear environment by using of Genetic algorithm nonlinear programming techniques. The results application of the above two approaches on 6-bus and 26-bus system verify that the far-end faults consideration on OC problem formulation don-t lose the optimality.
Abstract: Distance protection of transmission lines including advanced flexible AC transmission system (FACTS) devices has been a very challenging task. FACTS devices of interest in this paper are static synchronous series compensators (SSSC) and unified power flow controller (UPFC). In this paper, a new algorithm is proposed to detect and classify the fault and identify the fault position in a transmission line with respect to a FACTS device placed in the midpoint of the transmission line. Discrete wavelet transformation and wavelet entropy calculations are used to analyze during fault current and voltage signals of the compensated transmission line. The proposed algorithm is very simple and accurate in fault detection and classification. A variety of fault cases and simulation results are introduced to show the effectiveness of such algorithm.
Abstract: This paper presents the mathematical model of electric field and magnetic field in transmission system, which performs in second-order partial differential equation. This research has conducted analyzing the electromagnetic field radiating to atmosphere around the transmission line, when there is the transmission line transposition in case of long distance distribution. The six types of 500 kV transposed HV transmission line with double circuit will be considered. The computer simulation is applied finite element method that is developed by MATLAB program. The problem is considered to two dimensions, which is time harmonic system with the graphical performance of electric field and magnetic field. The impact from simulation of six types long distance distributing transposition will not effect changing of electric field and magnetic field which surround the transmission line.
Abstract: A simple mobile engine-driven pneumatic paddy
collector made of locally available materials using local
manufacturing technology was designed, fabricated, and tested for
collecting and bagging of paddy dried on concrete pavement. The
pneumatic paddy collector had the following major components:
radial flat bladed type centrifugal fan, power transmission system,
bagging area, frame and the conveyance system. Results showed
significant differences on the collecting capacity, noise level, and fuel
consumption when rotational speed of the air mover shaft was varied.
Other parameters such as collecting efficiency, air velocity,
augmented cracked grain percentage, and germination rate were not
significantly affected by varying rotational speed of the air mover
shaft. The pneumatic paddy collector had a collecting efficiency of
99.33 % with a collecting capacity of 2685.00 kg/h at maximum
rotational speed of centrifugal fan shaft of about 4200 rpm. The
machine entailed an investment cost of P 62,829.25. The break-even
weight of paddy was 510,606.75 kg/yr at a collecting cost of 0.11
P/kg of paddy. Utilizing the machine for 400 hours per year
generated an income of P 23,887.73. The projected time needed to
recover cost of the machine based on 2685 kg/h collecting capacity
was 2.63 year.
Abstract: The power consumption of an Optical Packet Switch
equipped with SOA technology based Spanke switching fabric is
evaluated. Sophisticated analytical models are introduced to evaluate
the power consumption versus the offered traffic, the main
switch parameters, and the used device characteristics. The impact
of Amplifier Spontaneous Emission (ASE) noise generated by a
transmission system on the power consumption is investigated. As
a matter of example for 32×32 switches supporting 64 wavelengths
and offered traffic equal to 0,8, the average energy consumption per
bit is 5, 07 · 10-2 nJ/bit and increases if ASE noise introduced by
the transmission systems is increased.
Abstract: In this paper, we investigate the study of techniques
for scheduling users for resource allocation in the case of multiple
input and multiple output (MIMO) packet transmission systems. In
these systems, transmit antennas are assigned to one user or
dynamically to different users using spatial multiplexing. The
allocation of all transmit antennas to one user cannot take full
advantages of multi-user diversity. Therefore, we developed the case
when resources are allocated dynamically. At each time slot users
have to feed back their channel information on an uplink feedback
channel. Channel information considered available in the schedulers
is the zero forcing (ZF) post detection signal to interference plus
noise ratio. Our analysis study concerns the round robin and the
opportunistic schemes.
In this paper, we present an overview and a complete capacity
analysis of these schemes. The main results in our study are to give
an analytical form of system capacity using the ZF receiver at the
user terminal. Simulations have been carried out to validate all
proposed analytical solutions and to compare the performance of
these schemes.
Abstract: This paper focuses on PSS/E modeling of wind farms
of Doubly-fed Induction Generator (DFIG) type and their impact on
issues of power system operation. Since Wind Turbine Generators
(WTG) don-t have the same characteristics as synchronous
generators, the appropriate modeling of wind farms is essential for
transmission system operators to analyze the best options of
transmission grid reinforcements as well as to evaluate the wind
power impact on reliability and security of supply. With the high
excepted penetration of wind power into the power system a
simultaneous loss of Wind Farm generation will put at risk power
system security and reliability. Therefore, the main wind grid code
requirements concern the fault ride through capability and frequency
operation range of wind turbines. In case of grid faults wind turbines
have to supply a definite reactive power depending on the
instantaneous voltage and to return quickly to normal operation.
Abstract: Recently, Genetic Algorithms (GA) and Differential
Evolution (DE) algorithm technique have attracted considerable
attention among various modern heuristic optimization techniques.
Since the two approaches are supposed to find a solution to a given
objective function but employ different strategies and computational
effort, it is appropriate to compare their performance. This paper
presents the application and performance comparison of DE and GA
optimization techniques, for flexible ac transmission system
(FACTS)-based controller design. The design objective is to enhance
the power system stability. The design problem of the FACTS-based
controller is formulated as an optimization problem and both the PSO
and GA optimization techniques are employed to search for optimal
controller parameters. The performance of both optimization
techniques has been compared. Further, the optimized controllers are
tested on a weekly connected power system subjected to different
disturbances, and their performance is compared with the
conventional power system stabilizer (CPSS). The eigenvalue
analysis and non-linear simulation results are presented and
compared to show the effectiveness of both the techniques in
designing a FACTS-based controller, to enhance power system
stability.
Abstract: This paper presents a systematic procedure for modelling and simulation of a power system installed with a power system stabilizer (PSS) and a flexible ac transmission system (FACTS)-based controller. For the design purpose, the model of example power system which is a single-machine infinite-bus power system installed with the proposed controllers is developed in MATLAB/SIMULINK. In the developed model synchronous generator is represented by model 1.1. which includes both the generator main field winding and the damper winding in q-axis so as to evaluate the impact of PSS and FACTS-based controller on power system stability. The model can be can be used for teaching the power system stability phenomena, and also for research works especially to develop generator controllers using advanced technologies. Further, to avoid adverse interactions, PSS and FACTS-based controller are simultaneously designed employing genetic algorithm (GA). The non-linear simulation results are presented for the example power system under various disturbance conditions to validate the effectiveness of the proposed modelling and simultaneous design approach.
Abstract: Preliminary studies on Kuwait high voltage
transmission system show significant increase in the short circuit
level at some of the grid substations and some generating stations.
This increase results from the growth in the power transmission
systems in size and complexity. New generating stations are expected
to be added to the system within the next few years. This paper
describes the study analysis performed to evaluate the available and
potential solutions to control SC levels in Kuwait power system. It
also presents a modified planning of the transmission network in
order to fulfill this task.
Abstract: In this paper, genetic algorithm (GA) opmization technique is applied to design Flexible AC Transmission System (FACTS)-based damping controllers. Two types of controller structures, namely a proportional-integral (PI) and a lead-lag (LL) are considered. The design problem of the proposed controllers is formulated as an optimization problem and GA is employed to search for optimal controller parameters. By minimizing the time-domain based objective function, in which the deviation in the oscillatory rotor speed of the generator is involved; stability performance of the system is improved. The proposed controllers are tested on a weakly connected power system subjected to different disturbances. The non-linear simulation results are presented to show the effectiveness of the proposed controller and their ability to provide efficient damping of low frequency oscillations. It is also observed that the proposed SSSC-based controllers improve greatly the voltage profile of the system under severe disturbances. Further, the dynamic performances of both the PI and LL structured FACTS-controller are analyzed at different loading conditions and under various disturbance condition as well as under unbalanced fault conditions..
Abstract: This paper presents the impact study of apparent
reactance injected by series Flexible AC Transmission System
(FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the
measured impedance of a 400 kV single electrical transmission line
in the presence of phase to earth fault with fault resistance. The study
deals with an electrical transmission line of Eastern Algerian
transmission networks at Group Sonelgaz (Algerian Company of
Electrical and Gas) compensated by TCSR connected at midpoint of
the line. This compensator used to inject active and reactive powers
is controlled by three TCSR-s. The simulations results investigate the
impacts of the TCSR on the parameters of short circuit calculation
and parameters of measured impedance by distance relay in the
presence of earth fault for three cases study.