Abstract: This paper presents a digital non-linear pulse-width modulation (PWM) controller in a high-voltage (HV) buck-boost DC-DC converter for the piezoelectric transducer of the down-hole acoustic telemetry system. The proposed design controls the generation of output signal with voltage higher than the supply voltage and is targeted to work under high temperature. To minimize the power consumption and silicon area, a simple and efficient design scheme is employed to develop the PWM controller. The proposed PWM controller consists of serial to parallel (S2P) converter, data assign block, a mode and duty cycle controller (MDC), linearly PWM (LPWM) and noise shaper, pulse generator and clock generator. To improve the reliability of circuit operation at higher temperature, this design is fabricated with the 1.0-μm silicon-on-insulator (SOI) CMOS process. The implementation results validated that the proposed design has the advantages of smaller size, lower power consumption and robust thermal stability.
Abstract: Carrier-based methods have been used widely for switching of multilevel inverters due to their simplicity, flexibility and reduced computational requirements compared to space vector modulation (SVM). This paper focuses on Multicarrier Sinusoidal Pulse Width Modulation (MCSPWM) strategy for the three phase Five-Level Flying Capacitor Inverter (5LFCI). The inverter is simulated for Induction Motor (IM) load and Total Harmonic Distortion (THD) for output waveforms is observed for different controlling schemes.
Abstract: In this paper, an improved active snubber cell is proposed on account of soft switching (SS) family of pulse width modulation (PWM) DC-DC converters. The improved snubber cell provides zero-voltage transition (ZVT) turn on and zero-current transition (ZCT) turn off for main switch. The snubber cell decreases EMI noise and operates with SS in a wide range of line and load voltages. Besides, all of the semiconductor devices in the converter operate with SS. There is no additional voltage and current stress on the main devices. Additionally, extra voltage stress does not occur on the auxiliary switch and its current stress is acceptable value. The improved converter has a low cost and simple structure. The theoretical analysis of converter is clarified and the operating states are given in detail. The experimental results of converter are obtained by prototype of 500 W and 100 kHz. It is observed that the experimental results and theoretical analysis of converter are suitable with each other perfectly.
Abstract: Fresh water is one of the resources which is getting
depleted day by day. A wise method to address this issue is by the
application of renewable energy-sun irradiation and by means of
decentralized, cheap, energetically self-sufficient, robust and simple
to operate plants, distillates can be obtained from sea, river or even
sewage. Solar desalination is a technique used to desalinate water
using solar energy. The present work deals with the comprehensive
design and simulation of solar tracking system using LabVIEW,
temperature and mass flow rate control of the solar desalination plant
using LabVIEW and also analysis of single phase inverter circuit
with LC filters for solar pumping system in MATLAB. The main
objective of this work is to improve the performance of solar
desalination system using automatic tracking system, output control
using temperature and mass flow rate control system and also to
reduce the harmonic distortion in the solar pumping system by means
of LC filters. The simulation of single phase inverter was carried out
using MATLAB and the output waveforms were analyzed.
Simulations were performed for optimum output temperature control,
which in turn controls the mass flow rate of water in the thermal
collectors. Solar tracking system was accomplished using LABVIEW
and was tested successfully. The thermal collectors are tracked in
accordance with the sun’s irradiance levels, thereby increasing the
efficiency of the thermal collectors.
Abstract: The photovoltaic (PV) panel with no galvanic
isolation system is well known technique in the world which is
effective and delivers power with enhanced efficiency. The PV
generation presented here is for stand-alone system installed in
remote areas when as the resulting power gets connected to electronic
load installation instead of being tied to the grid. Though very small,
even then transformer-less topology is shown to be with leakage in
pico-ampere range. By using PWM technique PWM, leakage current
in different situations is shown. The results shown in this paper show
how the pico-ampere current is reduced to femto-ampere through use
of inductors and capacitors of suitable values of inductor and
capacitors with the load.
Abstract: Space Vector Pulse Width Modulation is popular for
variable frequency drives. The method has several advantages over
carried based PWM and is computation intensive. The
implementation of SVPWM for multilevel inverter requires special
attention and at the same time consumes considerable resources. Due
to faster processing power and reduced over all computational
burden, FPGAs are being investigated as an alternative for other
controllers. In this paper, a space vector PWM algorithm is
implemented using FPGA which requires less computational area and
is modular in structure. The algorithm is verified experimentally for
Neutral Point Clamped inverter using FPGA development board
xc3s5000-4fg900.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: This paper introduces a boost converter with a new
active snubber cell. In this circuit, all of the semiconductor
components in the converter softly turns on and turns off with the
help of the active snubber cell. Compared to the other converters, the
proposed converter has advantages of size, number of components
and cost. The main feature of proposed converter is that the extra
voltage stresses do not occur on the main switches and main diodes.
Also, the current stress on the main switch is acceptable level.
Moreover, the proposed converter can operates under light load
conditions and wide input line voltage. In this study, the operating
principle of the proposed converter is presented and its operation is
verified with the Proteus simulation software for a 1 kW and 100 kHz
model.
Abstract: Fast speed drives for Permanent Magnet Synchronous
Motor (PMSM) is a crucial performance for the electric traction
systems. In this paper, PMSM is derived with a Model-based
Predictive Control (MPC) technique. Fast speed tracking is achieved
through optimization of the DC source utilization using MPC. The
technique is based on predicting the optimum voltage vector applied
to the driver. Control technique is investigated by comparing to the
cascaded PI control based on Space Vector Pulse Width Modulation
(SVPWM). MPC and SVPWM-based FOC are implemented with the
TMS320F2812 DSP and its power driver circuits. The designed MPC
for a PMSM drive is experimentally validated on a laboratory test
bench. The performances are compared with those obtained by a
conventional PI-based system in order to highlight the improvements,
especially regarding speed tracking response.
Abstract: This article presents two methods for the
compensation of harmonics generated by a nonlinear load. The first is
the classic method P-Q. The second is the controller by modern
method of artificial intelligence specifically fuzzy logic. Both
methods are applied to a shunt Active Power Filter (sAPF) based on a
three-phase voltage converter at five levels NPC topology. In
calculating the harmonic currents of reference, we use the algorithm
P-Q and pulse generation, we use the intersective PWM. For
flexibility and dynamics, we use fuzzy logic. The results give us clear
that the rate of Harmonic Distortion issued by fuzzy logic is better
than P-Q.
Abstract: This paper proposes five level diode clamped Z source
Inverter. The existing PWM techniques used for ZSI are restricted for
two level. The two level Z Source Inverter have high harmonic
distortions which effects the performance of the grid connected PV
system. To improve the performance of the system the number of
voltage levels in the output waveform need to be increased. This
paper presents comparative analysis of a five level diode clamped Z
source Inverter with different carrier based Modified Pulse Width
Modulation techniques. The parameters considered for comparison
are output voltage, voltage gain, voltage stress across switch and total
harmonic distortion when powered by same DC supply. Analytical
results are verified using MATLAB.
Abstract: The paper presents a practical three-phase PWM
inverter suitable for low voltage, low rating energy efficient systems.
The work in the paper is conducted with the view to establishing the
significance of the loss contribution from the PWM inverter in the
determination of the complete losses of a photovoltaic (PV) arraypowered
induction motor drive water pumping system. Losses
investigated include; conduction and switching loss of the devices
and gate drive losses. It is found that the PWM inverter operates at a
reasonable variable efficiency that does not fall below 92%
depending on the load. The results between the simulated and
experimental results for the system with or without a maximum
power tracker (MPT) compares very well, within an acceptable range
of 2% margin.
Abstract: This paper presents the simulation results of the
effects of sampling frequency on the total harmonic distortion (THD)
of three-phase inverters using the space vector pulse width
modulation (SVPWM) and space vector control (SVC) algorithms.
The relationship between the variables was studied using curve fitting
techniques, and it has been shown that, for 50 Hz inverters, there is
an exponential relation between the sampling frequency and THD up
to around 8500 Hz, beyond which the performance of the model
becomes irregular, and there is an negative exponential relation
between the sampling frequency and the marginal improvement to
the THD. It has also been found that the performance of SVPWM is
better than that of SVC with the same sampling frequency in most
frequency range, including the range where the performance of the
former is irregular.
Abstract: Solenoid operated electromagnetic control valve
(ECV) playing an important role for car’s air conditioning control
system. ECV is used in external variable displacement swash plate
type compressor and controls the entire air conditioning system by
means of a pulse width modulation (PWM) input signal supplying
from an external source (controller). Complete form of ECV contains
number of internal features like valve body, core, valve guide,
plunger, guide pin, plunger spring, bellows etc. While designing the
ECV; dimensions of different internal items must meet the standard
requirements as it is quite challenging. In this research paper,
especially the dimensioning of ECV body and its three pressure ports
through which the air/refrigerant passes are considered. Here internal
leakage test analysis of ECV body is being carried out from its
discharge port (Pd) to crankcase port (Pc) when the guide valve is
placed inside it. The experiments have made both in ordinary and
digital system using different assumptions and thereafter compare the
results.
Abstract: With advances in solid-state power electronic devices
and microprocessors, various pulse-width-modulation (PWM)
techniques have been developed for industrial applications. This
paper presents the comparison of two different PWM techniques, the
sinusoidal PWM (SPWM) technique and the space-vector PWM
(SVPWM) technique applied to two level VSI for micro grid
applications. These two methods are compared by discussing their
ease of implementation and by analyzing the output harmonic spectra
of various output voltages (line-to-neutral voltages, and line-to-line
voltages) and their total harmonic distortion (THD). The SVPWM
technique in the under-modulation region can increase the
fundamental output voltage by 15.5% over the SPWM technique.
Abstract: In this paper, we present a comparative assessment of
Space Vector Pulse Width Modulation (SVPWM) and Model
Predictive Control (MPC) for two-level three phase (2L-3P) Voltage
Source Inverter (VSI). VSI with associated system is subjected to
both control techniques and the results are compared.
Matlab/Simulink was used to model, simulate and validate the
control schemes. Findings of this study show that MPC is superior to
SVPWM in terms of total harmonic distortion (THD) and
implementation.
Abstract: This paper presents a hybrid three phase rectifier for
high power factor application. This rectifier is composed by zero
voltage transition (ZVT) and zero current transition (ZCT) boost
converter with three phase diode bridge rectifier, in parallel with a six
pulse three phase pulse width modulation (PWM) controlled rectifier.
The proposed topology is capable of high power factor with DC
output voltage regulation by providing sinusoidal input. Also, it
increases the overall efficiency of the new hybrid rectifier to 94.56%
and the total harmonic distortion of the hybrid structure varies from
0% to 16% at nominal output power. This topology was simulated in
MATLAB/SIMULINK environment and the output waveforms
presented with experimental result.
Abstract: Among all FACTS devices, the unified power flow
controller (UPFC) is considered to be the most versatile device.
This is due to its capability to control all the transmission system
parameters (impedance, voltage magnitude, and phase angle). With
the growing interest in UPFC, the attention to develop a mathematical
model has increased. Several models were introduced for UPFC in
literature for different type of studies in power systems. In this paper
a novel comparison study between two dynamic models of UPFC
with their proposed control strategies.
Abstract: Most of the PV systems are designed with transformer for safety purpose with galvanic isolation. However, the transformer is big, heavy and expensive. Also, it reduces the overall frequency of the conversion stage. Generally PV inverter with transformer is having efficiency around 92%–94% only. To overcome these problems, transformerless PV system is introduced. It is smaller, lighter, cheaper and higher in efficiency. However, dangerous leakage current will flow between PV array and the grid due to the stray capacitance. There are different types of configurations available for transformerless inverters like H5, H6, HERIC, oH5, and Dual paralleled buck inverter. But each configuration is suffering from its own disadvantages like high conduction losses, shoot-through issues of switches, dead-time requirements at zero crossing instants of grid voltage to avoid grid shoot-through faults and MOSFET reverse recovery issues. The main objective of the proposed transformerless inverter is to address two key issues: One key issue for a transformerless inverter is that it is necessary to achieve high efficiency compared to other existing inverter topologies. Another key issue is that the inverter configuration should not have any shoot-through issues for higher reliability.
Abstract: For Common R or R-L load to apply arbitrary voltage,
the bridge traditional inverters don’t have any difficulties by PWM
method. However for driving some piezoelectric actuator, arbitrary
voltage not a pulse but a steady voltage should be applied.
Piezoelectric load is considered as R-C load and its voltage does not
decrease even though the applied voltage decreases. Therefore it needs
some special inverter with circuit that can discharge the capacitive
energy. Especially for unidirectional arbitrary voltage driving like as
sine wave, it becomes more difficult problem. In this paper, a charge
and discharge circuit for unidirectional arbitrary voltage driving for
piezoelectric actuator is proposed. The circuit has charging and
discharging switches for increasing and decreasing output voltage.
With the proposed simple circuit, the load voltage can have any
unidirectional level with tens of bandwidth because the load voltage
can be adjusted by switching the charging and discharging switch
appropriately. The appropriateness is proved from the simulation of
the proposed circuit.