Abstract: Solar air heater is a type of heat exchanger which
transforms solar radiation into heat energy. The thermal performance
of conventional solar air heater has been found to be poor because of
the low convective heat transfer coefficient from the absorber plate to
the air. It is attributed to the formation of a very thin boundary layer
at the absorber plate surface commonly known as viscous sub-layer.
Thermal efficiency of solar air heater can be improved by providing
the artificial roughness on absorber plate is the most efficient
technique. In this paper an attempt is made to provide artificial
roughness by incorporating inclined multiple V-ribs in the underside
of the absorber plate. 60˚V – ribs are arranged inclined to the
direction of air flow. Performance of collector estimated theoretically
and experimentally. Results of the investigation reveal that thermal
efficiency of collector with multiple V-ribs increased by 14%.
Abstract: The levels of maximum power density of GSM
signals in the cities of Lagos, Ibadan and Abuja were studied.
Measurements were made with a calibrated hand held spectrum
analyzer 200m away from 271 base stations, at 1.2m to the ground
level. The maximum GSM 900 signal power density was
139.63μW/m2 in Lagos, 162.49μW/m2 in Ibadan and 5411.26μW/m2
in Abuja. Also, the maximum GSM 1800 signal power density was
296.82μW/m2 in Lagos, 116.82μW/m2 in Ibadan and 1263.00μW/m2
in Abuja. The level of power density of GSM 900 and GSM 1800
signals in the cities of Lagos, Ibadan and Abuja are far less than the
recommended value of 4.5W/m2 for GSM 900 and 9.0 W/m2 for
GSM 1800 by the ICNRP guideline. It can be concluded that
exposure to GSM signals in these cities cannot contribute to the
health detriments caused by thermal effects of radiofrequency
radiation.
Abstract: The electric power supplied by a photovoltaic power
generation systems depends on the solar irradiation and temperature.
The PV system can supply the maximum power to the load at a
particular operating point which is generally called as maximum
power point (MPP), at which the entire PV system operates with
maximum efficiency and produces its maximum power. Hence, a
Maximum power point tracking (MPPT) methods are used to
maximize the PV array output power by tracking continuously the
maximum power point. The proposed MPPT controller is designed
for 10kW solar PV system installed at Cape Institute of Technology.
This paper presents the fuzzy logic based MPPT algorithm. However,
instead of one type of membership function, different structures of
fuzzy membership functions are used in the FLC design. The
proposed controller is combined with the system and the results are
obtained for each membership functions in Matlab/Simulink
environment. Simulation results are decided that which membership
function is more suitable for this system.
Abstract: This article is deal with the experimental
investigations of the laser diode matrixes (LDM) based on the
AlGaAs/GaAs heterostructures (lasing wavelength 790-880 nm) to
find optimal LDM parameters for active vision systems. In particular,
the dependence of LDM radiation pulse power on the pulse duration
and LDA active layer heating as well as the LDM radiation
divergence are discussed.
Abstract: Vacuum Insulation Panel (VIP) can achieve very low
thermal conductivity by evacuating its inner space. Heat transfer in the
core materials of highly-evacuated VIP occurs by conduction through
the solid structure and radiation through the pore. The effect of various
scattering modes in combined conduction-radiation in VIP is
investigated through numerical analysis. The discrete ordinates
interpolation method (DOIM) incorporated with the commercial code
FLUENT® is employed. It is found that backward scattering is more
effective in reducing the total heat transfer while isotropic scattering is
almost identical with pure absorbing/emitting case of the same optical
thickness. For a purely scattering medium, the results agrees well with
additive solution with diffusion approximation, while a modified term
is added in the effect of optical thickness to backward scattering is
employed. For other scattering phase functions, it is also confirmed
that backwardly scattering phase function gives a lower effective
thermal conductivity. Thus the materials with backward scattering
properties, with radiation shields are desirable to lower the thermal
conductivity of VIPs.
Abstract: In this research article a comprehensive investigation
has been carried out to determine the effect of thermal cycle on
temperature dependent process parameters developed during gas
tungsten arc (GTA) welding of high carbon (AISI 1090) steel butt
joints. An experiment based thermal analysis has been performed to
obtain the thermal history. We have focused on different
thermophysical properties such as thermal conductivity, heat transfer
coefficient and cooling rate. Angular torch model has been utilized to
find out the surface heat flux and its variation along the fusion zone as
well as along the longitudinal direction from fusion boundary. After
welding and formation of weld pool, heat transfer coefficient varies
rapidly in the vicinity of molten weld bead and heat affected zone. To
evaluate the heat transfer coefficient near the fusion line and near the
rear end of the plate (low temperature region), established correlation
has been implemented and has been compared with empirical
correlation which is noted as coupled convective and radiation heat
transfer coefficient. Change in thermal conductivity has been
visualized by analytical model of moving point heat source. Rate of
cooling has been estimated by using 2-dimensional mathematical
expression of cooling rate and it has shown good agreement with
experimental temperature cycle. Thermophysical properties have been
varied randomly within 0 -10s time span.
Abstract: A novel simulation method to determine the
displacements of machine tools due to thermal factors is presented.
The specific characteristic of this method is the employment of
original CAD data from the design process chain, which is
interpreted by an algorithm in terms of geometry-based allocation of
convection and radiation parameters. Furthermore analogous models
relating to the thermal behaviour of machine elements are
automatically implemented, which were gained by extensive
experimental testing with thermography imaging. With this a
transient simulation of the thermal field and in series of the
displacement of the machine tool is possible simultaneously during
the design phase. This method was implemented and is already used
industrially in the design of machining centres in order to improve
the quality of herewith manufactured workpieces.
Abstract: This paper considers the characterization of a complex
electromagnetic environment due to multiple sources of
electromagnetic radiation as a five-dimensional surface which can be
described by a set of several surface sections including: instant EM
field intensity distribution maps at a given frequency and altitude,
instantaneous spectrum at a given location in space and the time
evolution of the electromagnetic field spectrum at a given point in
space. This characterization if done over time can enable the
exposure levels of Radio Frequency Radiation at every point in the
analysis area to be determined and results interpreted based on
comparison of the determined RFR exposure level with the safe
guidelines for general public exposure given by recognized body
such as the International commission on non-ionizing radiation
protection (ICNIRP), Institute of Electrical and Electronic Engineers
(IEEE), the National Radiation Protection Authority (NRPA).
Abstract: The theoretical approach is developed to describe the
change of drops in the atmosphere of own steam and buffer gas under
irradiation. It is shown that the irradiation influences on size of stable
droplet and on the conditions under which the droplet exists. Under
irradiation the change of drop becomes more complex: the not
monotone and periodical change of size of drop becomes possible.
All possible solutions are represented by means of phase portrait. It is
found all qualitatively different phase portraits as function of critical
parameters: rate generation of clusters and substance density.
Abstract: The mathematical analysis on radiation obtained and
the development of the solar photovoltaic (PV) array groundwater
pumping is needed in the rural areas of Thohoyandou for sizing and
power performance subject to the climate conditions within the area.
A simple methodology approach is developed for the directed
coupled solar, controller and submersible ground water pump system.
The system consists of a PV array, pump controller and submerged
pump, battery backup and charger controller. For this reason, the
theoretical solar radiation is obtained for optimal predictions and
system performance in order to achieve different design and
operating parameters. Here the examination of the PV schematic
module in a Direct Current (DC) application is used for obtainable
maximum solar power energy for water pumping. In this paper, a
simple efficient photovoltaic water pumping system is presented with
its theoretical studies and mathematical modeling of photovoltaics
(PV) system.
Abstract: Ficus deltoidea from the Moraceae family is a popular
medicinal herb in Malaysia. It possesses strong antioxidant and antiinflammatory
properties. In the present study, the anti-inflammatory
effects of F. deltoidea extract on UVB-irradiated HaCaT
Keratinocytes were investigated. HaCaT Keratinocytes were UVBirradiated
(12.5 mJ/cm3) and were treated with 0.05, 0.08 or 0.1% of
F. deltoidea extract. Cell viability following UVB irradiation was
significantly higher in the groups treated with the F. deltoidea extract
at doses of 0.05, 0.08 or 0.1% than in control group with UVB
irradiation only. Tumor necrosis factor-α (TNF-α), interleukin-1α
(IL-1α), interleukin-6 (IL-6) and cyclooxygenase (COX-2) play
primary roles in the inflammation process upon UV irradiation and
are known to be stimulated by UVB irradiation. Treatment with the
F. deltoidea extract dramatically inhibited the UV-induced TNF-α,
IL-1α, IL-6, and COX-2 expression. These results suggest that the F.
deltoidea extract inhibits the production of pro-inflammatory
cytokines and may be an effective protective agent for the treatment
of skin diseases.
Abstract: This study focuses on the cooling of a photovoltaic
panel (PV). Indeed, the cooling improves the conversion capacity of
this one and maintains, under extreme conditions of air temperature,
the panel temperature at an appreciable level which avoids the
altering. To do this, a fan provides forced circulation of air. Because
the fan is supplied by the panel, it is necessary to determine the
optimum operating point that unites efficiency of the PV with the
consumption of the fan. For this matter, numerical simulations are
performed at varying mass flow rates of air, under two extreme air
temperatures (50°C, 25°C) and a fixed solar radiation (1000W.m2) in
a case of no wind.
Abstract: In this study, first thermoplastic composite materials
/plates that have high ballistic impact resistance were produced. For
this purpose, the thermoplastic prepreg and the vacuum bagging
technique were used to produce a composite material. Thermoplastic
prepregs (resin-impregnated fiber) that are supplied ready to be used,
namely high-density polyethylene (HDPE) was chosen as matrix and
unidirectional glass fiber was used as reinforcement. In order to
compare the fiber configuration effect on mechanical properties,
unidirectional and biaxial prepregs were used. Then the
microstructural properties of the composites were investigated with
scanning electron microscopy (SEM) analysis. Impact properties of
the composites were examined by Charpy impact test and tensile
mechanical tests and then the effects of ultraviolet irradiation were
investigated on mechanical performance.
Abstract: In this study, a three dimensional numerical heat
transfer model has been used to simulate the laser structuring of
polymer substrate material in the Three-Dimensional Molded
Interconnect Device (3D MID) which is used in the advanced multifunctional
applications. A finite element method (FEM) transient
thermal analysis is performed using APDL (ANSYS Parametric
Design Language) provided by ANSYS. In this model, the effect of
surface heat source was modeled with Gaussian distribution, also the
effect of the mixed boundary conditions which consist of convection
and radiation heat transfers have been considered in this analysis. The
model provides a full description of the temperature distribution, as
well as calculates the depth and the width of the groove upon material
removal at different set of laser parameters such as laser power and
laser speed. This study also includes the experimental procedure to
study the effect of laser parameters on the depth and width of the
removal groove metal as verification to the modeled results. Good
agreement between the experimental and the model results is
achieved for a wide range of laser powers. It is found that the quality
of the laser structure process is affected by the laser scan speed and
laser power. For a high laser structured quality, it is suggested to use
laser with high speed and moderate to high laser power.
Abstract: The sound pressure level (SPL) of the moving-coil
loudspeaker (MCL) is often simulated and analyzed using the lumped
parameter model. However, the SPL of a MCL cannot be simulated
precisely in the high frequency region, because the value of cone
effective area is changed due to the geometry variation in different
mode shapes, it is also related to affect the acoustic radiation mass and
resistance. Herein, the paper presents the inverse method which has a
high ability to measure the value of cone effective area in various
frequency points, also can estimate the MCL electroacoustic
parameters simultaneously. The proposed inverse method comprises
the direct problem, adjoint problem, and sensitivity problem in
collaboration with nonlinear conjugate gradient method. Estimated
values from the inverse method are validated experimentally which
compared with the measured SPL curve result. Results presented in
this paper not only improve the accuracy of lumped parameter model
but also provide the valuable information on loudspeaker cone design.
Abstract: In this paper, the design of a coaxial feed single layer rectangular microstrip patch antenna for three different wireless communication band applications is presented. The proposed antenna is designed by using substrate Roger RT/duroid 5880 having permittivity of about 2.2 and tangent loss of 0.0009. The characteristics of the substrate are designed and to evaluate the performance of modeled antenna using HFSS v.11 EM simulator, from Ansoft. The proposed antenna has small in size and operates at 2.25GHz, 3.76GHz and 5.23GHz suitable for mobile satellite service (MSS) network, WiMAX and WLAN applications. The dimension of the patch and slots are optimized to obtain these desired functional frequency ranges. The simulation results with frequency response, radiation pattern and return loss, VSWR, Input Impedance are presented with appropriate table and graph.
Abstract: The scope of this paper is to evaluate and compare the potential of LS-PV(Large Scale Photovoltaic Power Plant) power generation systems in the southern region of Libya at Al-Kufra for both stationary and tracking systems. A Microsoft Excel-VBA program has been developed to compute slope radiation, dew-point, sky temperature, and then cell temperature, maximum power output and module efficiency of the system for stationary system and for tracking system. The results for energy production show that the total energy output is 114GWh/year for stationary system and 148GWh/year for tracking system. The average module efficiency for the stationary system is 16.6% and 16.2% for the tracking system.
The values of electricity generation capacity factor (CF) and solar capacity factor (SCF) for stationary system were found to be 26% and 62.5% respectively and 34% and 82% for tracking system. The GCR (Ground Cover Ratio) for a stationary system is 0.7, which corresponds to a tilt angle of 24°. The GCR for tracking system was found to be 0.12. The estimated ground area needed to build a 50MW PV plant amounts to approx. 0.55km2 for a stationary PV field constituted by HIT PV arrays and approx. 91MW/ km2. In case of a tracker PV field, the required ground area amounts approx.2.4km2 and approx. 20.5MW/ km2.
Abstract: Blood gamma irradiation is the only available method
to prevent transfusion associated graft versus host disease (TAGVHD).
However, when blood is irradiated, determine blood shelf
time is crucial. Non irradiated blood have a self-time from 21 to 35
days when is preserved with anticoagulated solution and stored at
4°C. During their storage, red blood cells (RBC) undergo a series of
biochemical, biomechanical and molecular changes involving what is
known as storage lesion (SL). SL include loss of structural integrity
of RBC, decrease of 2,3-diphosphatidylglyceric acid levels, and
increase of both ion potassium concentration and hemoglobin (Hb).
On the other hand, Atomic force Microscopy (AFM) represents a
versatile tool for a nano-scale high resolution topographic analysis in
biological systems. In order to evaluate SL in irradiated and nonirradiated
blood, RBC topography and morphometric parameters
were obtained from an AFM XE-BIO system. Cell viability was
followed using flow cytometry. Our results showed that early
markers as nanoscale roughness, allow us to evaluate blood quality
since other perspective.
Abstract: We installed solar panels and digital meteorological equipments whose electrical power is supplied using PV on July 13, 2011. Then, the relationship between the electric power generation and the irradiation, air temperature, and wind velocity was investigated on a roof at a university. The electrical power generation, irradiation, air temperature, and wind velocity were monitored over two years. By analyzing the measured meteorological data and electric power generation data using PTC, we calculated the size of the solar panel that is most suitable for this system. We also calculated the wasted power generation using PTC with the measured meteorological data obtained in this study. In conclusion, to reduce the "wasted power generation", a smaller-size solar panel is required for stable operation.
Abstract: Effects of insertion of coiled wire in juxtaposition with twisted tapes on heat transfer rate and solar radiation without disturbing the flow inside the riser tubes in a solar flat plate collector is experimentally reconnoitered in this present work. The wire coil used as a turbulator is placed inside the riser tube while the twisted tape is inserted into the wire coil to create a continuous swirling flow along the tube wall. The results of the heat transfer have been compared well with the available results. The heat transfer rate in the collector has been found to be increased by 18% to 70%. Solar water heaters having inserts in the flow tubes perform better than the conventional plain ones. It has been observed that heat losses are reduced consequently increasing the thermal performance about 30% over the plain water heaters under the same operating conditions. The effect of twisted tape with wire coils, flow Reynolds number, and the intensity of solar radiation on the thermal performance of the solar water heater has been presented. Effects of insertion of coiled wire in juxtaposition with twisted tapes on heat transfer rate and solar radiation without disturbing the flow inside the riser tubes in a solar flat plate collector is experimentally reconnoitered in this present work. The wire coil used as a turbulator is placed inside the riser tube while the twisted tape is inserted into the wire coil to create a continuous swirling flow along the tube wall. The results of the heat transfer have been compared well with the available results. The heat transfer rate in the collector has been found to be increased by 18% to 70%. Solar water heaters having inserts in the flow tubes perform better than the conventional plain ones. It has been observed that heat losses are reduced consequently increasing the thermal performance about 30% over the plain water heaters under the same operating conditions. The effect of twisted tape with wire coils, flow Reynolds number, and the intensity of solar radiation on the thermal performance of the solar water heater has been presented.