Abstract: Electro-osmosis in clayey soils and sediments, for
purposes of clay consolidation, dewatering, or cleanup, and electro
injection in porous media is widespread recent decades. It is
experimentally found that the chemical properties of porous media
especially PH change the characteristics of media. Electro-osmotic
conductivity is a function of soil and grout material chemistry,
altering with time. Many numerical approaches exist to simulate the
of electro kinetic flow rate considering chemical changes. This paper
presents a simplified analytical solution for constant flow rate based
on varying electro osmotic conductivity and time dependent viscosity
for injection of colloidal silica.
Abstract: Polymeric composites are being increasingly used as
repair material for repairing critical infrastructures such as building,
bridge, pressure vessel, piping and pipeline. Technique in repairing
damaged pipes is one of the major concerns of pipeline owners.
Considerable researches have been carried out on the repair of
corroded pipes using composite materials. This article attempts a
short review of the subject matter to provide insight into various
techniques used in repairing corroded pipes, focusing on a wide range
of composite repair systems. These systems including pre-cured
layered, flexible wet lay-up, pre-impregnated, split composite sleeve
and flexible tape systems. Both advantages and limitations of these
repair systems were highlighted. Critical technical aspects have been
discussed through the current standards and practices. Research gaps
and future study scopes in achieving more effective design
philosophy are also presented.
Abstract: This experimental study consists of a characterization
of epoxy grout where an amount of 2% of graphene nanoplatelets
particles were added to commercial epoxy resin to evaluate their
behavior regarding neat epoxy resin. Compressive tests, tensile tests
and flexural tests were conducted to study the effect of graphene
nanoplatelets on neat epoxy resin. By comparing graphene-based and
neat epoxy grout, there is no significant increase of strength due to
weak interface in the graphene nanoplatelets/epoxy composites.
From this experiment, the tension and flexural strength of graphenebased
epoxy grouts is slightly lower than ones of neat epoxy grout.
Nevertheless, the addition of graphene has produced more consistent
results according to a smaller standard deviation of strength.
Furthermore, the graphene has also improved the ductility of the
grout, hence reducing its brittle behaviour. This shows that the
performance of graphene-based grout is reliably predictable and able
to minimise sudden rupture. This is important since repair design of
damaged pipeline is of deterministic nature.
Abstract: A Friction stir welding tool is a critical component to
the success of the process. The tool typically consists of a rotating
round shoulder and a threaded cylindrical pin that heats the work
piece, mostly by friction, and moves the softened alloy around it to
form the joint. In this research work, an attempt has been made to
investigate the relationship between FSW variables mainly tool
profile, rotating speed, welding speed and the mechanical properties
(tensile strength, yield strength, percentage elongation, and micro
hardness) of friction stir welded aluminum alloy 5083 joints. From
the experimental details, it can be assessed that the joint produced by
using Triflute profile tool has contribute superior mechanical and
structural properties as compared to Tapered unthreaded & Threaded
tool for 1000rpm.
Abstract: Highly stable and homogeneously dispersed amino
acid coated silver nanoparticles (ANP) of ≈ 10 nm diameter, ranging
from 420 to 430 nm are prepared on AgNO3 solution addition to gum
of Azadirachta indica solution at 373.15 K. The amino acids were
selected based on their polarity. The synthesized nanoparticles were
characterized by UV-Vis, FTIR spectroscopy, HR-TEM, XRD, SEM
and 1H-NMR. The coated nanoparticles were used as catalyst for the
reduction of methylene blue dye in presence of Sn(II) in aqueous,
anionic and cationic micellar media. The rate of reduction of dye was
determined by measuring the absorbance at 660 nm,
spectrophotometrically and followed the order: Kcationic > Kanionic >
Kwater. After 12 min and in absence of the ANP, only 2%, 3% and 6%
of the dye reduction was completed in aqueous, anionic and cationic
micellar media respectively while, in presence of ANP coated by
polar neutral amino acid with non-polar -R group, the reduction
completed to 84%, 95% and 98% respectively. The ANP coated with
polar neutral amino acid having non-polar -R group, increased the
rate of reduction of the dye by 94, 3205 and 6370 folds in aqueous,
anionic and cationic micellar media respectively. Also, the rate of
reduction of the dye increased by three folds when the micellar media
was changed from anionic to cationic when the ANP is coated by a
polar neutral amino acid having a non-polar -R group.