Internal Structure Formation in High Strength Fiber Concrete during Casting

Post cracking behavior and load –bearing capacity of the steel fiber reinforced high-strength concrete (SFRHSC) are dependent on the number of fibers are crossing the weakest crack (bridged the crack) and their orientation to the crack surface. Filling the mould by SFRHSC, fibers are moving and rotating with the concrete matrix flow till the motion stops in each internal point of the concrete body. Filling the same mould from the different ends SFRHSC samples with the different internal structures (and different strength) can be obtained. Numerical flow simulations (using Newton and Bingham flow models) were realized, as well as single fiber planar motion and rotation numerical and experimental investigation (in viscous flow) was performed. X-ray pictures for prismatic samples were obtained and internal fiber positions and orientations were analyzed. Similarly fiber positions and orientations in cracked cross-section were recognized and were compared with numerically simulated. Structural SFRHSC fracture model was created based on single fiber pull-out laws, which were determined experimentally. Model predictions were validated by 15x15x60cm prisms 4 point bending tests.




References:
[1] F. Laranjeira, S. Grunewald, J. Walraven, C. Blom, C. Molins and A.
Aguado Characterization of the orientation profile of steel fibers
reinforced concrete, Materials and Structures, Online 6 November 2010,
pp.1-19.
[2] L.Ferrara, N.Tregger and S.P.Shah Flow-induced fibers orientation in
SCSFRC: Monitoring and Prediction, In: Design, Production and
Placement of Self-Consolidating Concrete, Proceedings of SCC2010,
Montreal, September 26-29, 2010, pp.417-428.
[3] R. A. Krasnikovs& O. Kononova, Strength Prediction for Concrete
Reinforced by Different Length and Shape Short Steel Fibers, Sc.
Proceedings of RigaTechnicalUniversity. Transport and Engineering, 6,
vol.31, 2009, pp.89-93.
[4] A.Krasnikovs, O.Kononova&A.Pupurs, Steel Fiber Reinforced Concrete
Strength,Sc. Proceedings of RigaTechnicalUniversity. Transport and
Engineering, 6, vol.28, Riga, 2008, pp. 142-150.
[5] P. Laure, L. Silva, T. Coupez and F. Toussaint, Numerical modeling of
concrete flow with rigid fibers, In Cueto, E and Chinesta, F, editor, 10th
ESAFORM Conference on Material Forming, Pts A and B, volume 907
of AIP CONFERENCE PROCEEDINGS, pp. 1390-1395, 2007. 10th
ESAFORM Conference on Material Forming, Zaragoza, April 18-20,
2007.
[6] Advani, S. G. and C. L. Tucker III, The Use of Tensors to Describe and
Predict Fiber Orientation in Short Fiber Composites, Journal of
Rheology, 31:8, 751-784,
[7] Q.Zhang, J. Lin Orientation distribution and rheological properties of
fiber suspensions flowing through curved expansion and rotating ducts,
Journal of Hydrodynamics22(5), 2010, pp. 920-925.
[8] V.Lapsa and A.Krasnikovs Fiber reinforced concrete construction
element production technology. Latvian patent LV12807 B, 2000,
September 20.
[9] V.Lapsa, A.Krasnikovs, M.Eiduks, A.Pupurs Method for production the
oriented fiberconcrete structures. Latvian patent LV 13929 B.
20.07.2010.
[10] M. Eiduks, A. Krasnikovs, E. Dunskis, O. Kononova. Investigation of
Fiber Orientation in Viscous Fluid. Scientific Journal of
RigaTechnicalUniversity. "Transport and engineering", 6, vol. 33, Riga
2010; pp. 98 - 102.
[11] K. Yasuda, T. Kyuto and N. Mori An experimental study of flowinduced
fiber orientation and concentration distributions in a
concentrated suspension flow through a slit channel containing a
cylinder, Rheol Acta (2004) 43: pp.137-145.