Heat Stress Monitor by Using Low-Cost Temperature and Humidity Sensors

The aim of this study is to develop a cost-effective WBGT heat stress monitor which provides precise heat stress measurement. The proposed device employs SHT15 and DS18B20 as a temperature and humidity sensors, respectively, incorporating with ATmega328 microcontroller. The developed heat stress monitor was calibrated and adjusted to that of the standard temperature and humidity sensors in the laboratory. The results of this study illustrated that the mean percentage error and the standard deviation from the measurement of the globe temperature was 2.33 and 2.71 respectively, while 0.94 and 1.02 were those of the dry bulb temperature, 0.79 and 0.48 were of the wet bulb temperature, and 4.46 and 1.60 were of the relative humidity sensor. This device is relatively low-cost and the measurement error is acceptable.





References:
[1] D.S. Moran et al. An environmental stress index (ESI) as a substitute for
the wet bulb globe temperature (WBGT). Thermal Biology 26 (2001)
427-431
[2] Jose Perez-Alonso et al. Approach to the evaluation of the thermal work
environment in the greenhouse-construction industry of SE Spain.
Building and Environment 46 (2011) 1725e1734
[3] American Conference of Governmental Industrial Hygienists. TLV &
BEI based on the documentation for the threshold limit values for
chemical substance and physical agents & biological exposure indices. 2008
[4] Chalermchai Chaikittiporn. Safety and environment for industrial. Department of Environmental Quality Promotion, Ministry of Natural
Resources and Environment
[5] Pornpimol Kongtip. Industrial hygiene, Department of occupational
health and safety, Faculty of public health, Mahidol University.
[6] Wantanee Phanprasit, Mahidol University. The guideline for heat, light
and sound monitoring B.E. 2549. 2006
[7] Thailand Regulations, set standards for occupational health, safety and
environment to work on heat, light and sound B.E. 2549. 2006
[8] Aekkachai Makarn. Learn to use the AVR family of microcontrollers
with Arduino, ETT Company Limited
[9] Occupational safety and health bureau, Department of labour protection
and welfare, Sampling and Evaluation of Physical Environments
Manual, 2002
[10] G. Buonanno, A. Frattolillo, L. Vanoli. Direct and indirect measurement
of WBGT index in transversal flow, Measurement 29 (2001) 127-135
[11] Grahame M. Budd. Wet-bulb globe temperature (WBGT) - its history
and its limitations, Science and Medicine in Sport (2008) 11, 20 - 32