Functional Sample of the Portable Device for Fast Analysis of Explosives

The construction of original functional sample of the portable device for fast analysis of energetic materials has been described in the paper. The portable device consisting of two parts – an original miniaturized microcolumn liquid chromatograph and a unique chemiluminescence detector – has been proposed and realized. In a very short time, this portable device is capable of identifying selectively most of military nitramine- and nitroesterbased explosives as well as inorganic nitrates occurring in trace concentrations in water or in soil. The total time required for the identification of extracts is shorter than 8 minutes.





References:
[1] E. L. Holtoff, D. N.Stratis-Cullum, M. E. Hankus, A nanosensor for TNT detection based on molecularly imprinted polymers and surface enhanced raman scattering. Sensors, 2011, 11, pp. 2700-2714.
[2] J. G. Houston, G. R. Lotfu, Dietary exposure of flathead minnows to the explosives TNT and RDX and to the pesticide DDT using contaminated invertebrates. Int. J. Environ. Res. Public Health 2005, 2, pp. 286-292.
[3] Z.Veeefa, P. Mikugka, J. Kellner, J. Navratil, A. Langerova., Application of Portable Continuous Aerosol Concentrator. In Mathematical Methods and Techniques in Engineering & Environmental Science, Proceedings of the 4th WSEAS Conference on Sensors and Signals (SENSIG1 1). Catania, Sicily, Italy: WSEAS Press, 2011, pp. 271-276. ISBN 978-1-61804-046-6.
[4] Z. Friedel Biotransformation of military explosives. Researcher report of the project Ministry of Defence of the Czech Republic 2011, grant No. 0901 8 7150 R.
[5] A. B. Crockett, H. D. Craig, T. F. Jenkins, Field, Sampling and Selecting On-Site Analytical Methods for Explosives in Water; Report #EPA/600/S-99/002; United States Environmental Protection Agency: Las Vegas, NV, USA, 1999.
[6] V. Marinovic, S. Marinovic, M. Jovanovic, J. Jovanovic, S. Strbac, The electrochemical reduction of trinitrotoluene on a platinum wire modified by chemisorbed acetonitrile. J. Electroanal. Chem., 2010, 648, pp. 1-7.
[7] G. A. Eiceman, P. A. Stone, Peer reviewed: ion mobility spectrometers in national defense, Anal. Chem., 2004, vol. 76, no. 21, pp. 390-397.
[8] J. P. Smith, V. Hinson-Smith, The New Era of SAW Device, Anal. Chem., 2006, vol. 78, no. 11, pp. 3505-3507.
[9] J. V. Goodpaster, V. L. Mcguffin, Fluorescence quenching as an indirect detection method for nitrated explosives, Anal. Chem., 2001, vol. 73, no 9, pp. 2004-2011.
[10] M. S. Meaney, V. L. Mcguffin, Luminescence-based methods for sensing and detection of explosives, Anal. Bioanal. Chem., 2008, 391, pp. 2557-2576,
[11] E. Smith, G. Dent, Modem Raman Spectroscopy. A Practical Approach. Wiley, Chichester, 2005, pp. 2-8.