Experimental Evaluation of Drilling Damage on the Strength of Cores Extracted from RC Buildings

Concrete strength evaluated from compression tests
on cores is affected by several factors causing differences from the
in-situ strength at the location from which the core specimen was
extracted. Among the factors, there is the damage possibly occurring
during the drilling phase that generally leads to underestimate the
actual in-situ strength. In order to quantify this effect, in this study
two wide datasets have been examined, including: (i) about 500 core
specimens extracted from Reinforced Concrete existing structures,
and (ii) about 600 cube specimens taken during the construction of
new structures in the framework of routine acceptance control. The
two experimental datasets have been compared in terms of
compression strength and specific weight values, accounting for the
main factors affecting a concrete property, that is type and amount of
cement, aggregates' grading, type and maximum size of aggregates,
water/cement ratio, placing and curing modality, concrete age. The
results show that the magnitude of the strength reduction due to
drilling damage is strongly affected by the actual properties of
concrete, being inversely proportional to its strength. Therefore, the
application of a single value of the correction coefficient, as generally
suggested in the technical literature and in structural codes, appears
inappropriate. A set of values of the drilling damage coefficient is
suggested as a function of the strength obtained from compressive
tests on cores.





References:
<p>[1] CEN, 2005. Eurocode 8 - Design of structures for earthquake resistance
- Part 3: Assessment and retrofitting of buildings, EN 1998-3, Brussels.
[2] NTC 2008, Ministero delle Infrastrutture, DM 14 gennaio 2008, Norme
tecniche per le costruzioni, Suppl. or. n.30 alla G.U. n.29 del 4/2/2008
(in Italian).
[3] EN 12504 &ndash; 1, &ldquo;Testing concrete in structures &ndash; Cored specimens &ndash;
Taking, examining and testing in compression&rdquo;, 2000.
[4] M. Dolce, A. Masi, M. Ferrini, &ldquo;Estimation of the actual in-place
concrete strength in assessing existing RC structures&rdquo;, Proc. of the
Second International fib Congress, June 5-8, 2006, Naples, Italy.
[5] EN 13791, &quot;Assessment of in-situ compressive strength in structures and
precast concrete components&quot;, European Standard ICS 91.080.40, 2007.
[6] Concrete Society, &quot;Concrete core testing for strength&quot;, Technical Report
11 (TR 11), 1976.
[7] American Concrete Institute (ACI),&ldquo;Guide for Obtaining Cores and
Interpreting Compressive Strength Results&rdquo;, ACI 214.4R-10, Detroit,
June 2010.
[8] G. Cestelli Guidi, G. Morelli, &ldquo;Valutazione della resistenza dei
calcestruzzi sulle strutture finite&rdquo;, L&rsquo;industria italiana del cemento, n.
3/1981, (in Italian).
[9] P. Bocca, F. Cianfrone, &ldquo;Le prove non distruttive sulle costruzioni: una
metodologia combinata&rdquo;, L&rsquo;industria italiana del cemento, n. 6/1983, (in
Italian).
[10] M. Collepardi, &quot;Il nuovo calcestruzzo (seconda edizione)&quot;, Tintoretto
Ed., 2002 (in Italian).
[11] E. Donaggio, &ldquo;Manuale del calcestruzzo armato&rdquo;, Zanichelli Ed., 1990