Evaluation of Aquifer Protective Capacity and Soil Corrosivity Using Geoelectrical Method

A geoelectric survey was carried out in some parts of
Angwan Gwari, an outskirt of Lapai Local Government Area on
Niger State which belongs to the Nigerian Basement Complex, with
the aim of evaluating the soil corrosivity, aquifer transmissivity and
protective capacity of the area from which aquifer characterisation
was made. The G41 Resistivity Meter was employed to obtain fifteen
Schlumberger Vertical Electrical Sounding data along profiles in a
square grid network. The data were processed using interpex 1-D
sounding inversion software, which gives vertical electrical sounding
curves with layered model comprising of the apparent resistivities,
overburden thicknesses, and depth. This information was used to
evaluate longitudinal conductance and transmissivities of the layers.
The results show generally low resistivities across the survey area
and an average longitudinal conductance variation from
0.0237Siemens in VES 6 to 0.1261Siemens in VES 15 with almost
the entire area giving values less than 1.0 Siemens. The average
transmissivity values range from 96.45 Ω.m2 in VES 4 to 299070
Ω.m2 in VES 1. All but VES 4 and VES14 had an average
overburden greater than 400 Ω.m2, these results suggest that the
aquifers are highly permeable to fluid movement within, leading to
the possibility of enhanced migration and circulation of contaminants
in the groundwater system and that the area is generally corrosive.





References:
[1] Keller G., V. and Frischknecht, F. C. (1966). Electrical Methods in
Geophysical Prospecting. Pergamon Press, Oxford, New York, Toronto,
Sydney, Braunsckweig.
[2] Krumbein, W.C., and Sloss, L. L. (1963). Stratigraphy and
Sedimentation. W. H. Freeman and Co., San Francisco, 660 pp.
[3] Brousse, J. J. (1963). Modern geophysical methods for subsurface water
exploration: Geophysics, v. 28/4, p. 634-635.
[4] Ako, B.D., and Osondu, V.C. (1986). Electrical resistivity of the Kerri-
Kerri Formation, Darazo, Nigeria: Journal of African Earth Sciences, v.
5/5, p. 527-534.
[5] Olorunniwo, M.A., and Olorunfemi, M.O. (1987). Geophysical
Investigation for Groundwater in Precambrian Terrain, A case history
from Ikare, Southwest Nigeria. Journal of African Earth Sciences, v. 6,
p. 787-796.
[6] Olorunfemi, M.O., and Fasuyi, S.A. (1993). Aquifer Types and the
Geoelectric Hydrogeologic Characteristics of Parts of the Central
Basement Terrain of Nigeria, Niger State. Journal of African Earth
Sciences, v. 16/3, p 309-317.
[7] Ayolabi, E.A., Adeoti, L., Oshinlaja, N.A., Adeosuni, I.O., and Idowu,
O.I. (2009). Seismic Refraction and Resistivity Studies of part of
Igbogbo Township, Southwest Nigeria: Journal of Science Research
Development, v. 11, p. 42–61. Balkan Geophysical Society 1, 3-6. [8] Osuagwu, B.C. (2009). Geophysical investigation for groundwater in a
difficult terrain around Modomo Area, Ife, Osun State: Unpublished
Bachelor of Science Thesis, Obafemi Awolowo University, Ile-Ife, Osun
State, p. 88.
[9] Sustainable Human Settlement Consult Limited, (2004): Ibrahim
Badamasi Babangida University Master Plan.
[10] Obaje, N.G, Lar, A., Nzegbuna, A., Moumouni, A., Chaanda, M., and
Goki, N. (2006). Geology and Mineral Resources of Nasarawa State; An
investor’s Guide. Nasarawa Scientifique, 2, No. 1
[11] Oyawoye, M.O. (1964). The Geology of the Nigerian Basement
Complex. Journal of the Nigerian Mining, Geological and Metallurgical
Society, v. 1, p. 87-482.
[12] Rahaman, M.A. (1973). The Geology of the District around Iseyin,
Western Nigeria: Unpublished Ph.D Thesis, University of Ibadan, p.
268.
[13] Rahaman, M.A. (1976). Review of the Basement Geology of Southwest
Nigeria, Geology of Nigeria, in, C.A. Kogbe (ed.), Geology of Nigeria:
Elizabethan Publishing, p. 41-58.
[14] Rahaman, M.A. (1988). Recent Advances in the Study of the Basement
Complex of Nigeria: Precambrian Geology of Nigeria, G.S.N, p. 11-41.
[15] Odeyemi, I.B., (1978). Orogenic Events in the Precambrian Basement of
Nigeria, West Africa: Geol. Rdsch, v, 70, 879-909.
[16] Mohamed, A.S. (1975). Vertical Electrical Resistivity Soundings to
Locate Ground Water Resources: A Feasibility Study. Virginia Water
Resources Research Center Bulletin; 73: 7. New York.
[17] Olorunfemi, M. O., Ojo, J. S. and Akintunde, O.M. (1999). “Hydrogeophysical
evaluation of the groundwater potential of the Akure
metropolis, Southwestern Nigeria”. Journal of Mining and Geology Vol.
35(2) 1999, pp. 207 – 228.
[18] Henriet, J. P. (1975). Direct applications of the Dar Zarrouk parameters
in ground water surveys. Geophysical Prospecting, 24 (3): 44–353.
[19] Nwankwo, C. N. and Ehirim, C.N. (2010). Evaluation of aquifer
characteristics and groundwater quality using geoelectrical method in
Choba, Port Harcourt. Archives of applied science research, 2(2):396-
403.