Abstract: Terminal localization for indoor Wireless Local Area
Networks (WLANs) is critical for the deployment of location-aware
computing inside of buildings. A major challenge is obtaining high
localization accuracy in presence of fluctuations of the received signal
strength (RSS) measurements caused by multipath fading. This paper
focuses on reducing the effect of the distance-varying noise by spatial
filtering of the measured RSS. Two different survey point geometries
are tested with the noise reduction technique: survey points arranged
in sets of clusters and survey points uniformly distributed over the
network area. The results show that the location accuracy improves
by 16% when the filter is used and by 18% when the filter is applied
to a clustered survey set as opposed to a straight-line survey set.
The estimated locations are within 2 m of the true location, which
indicates that clustering the survey points provides better localization
accuracy due to superior noise removal.
Abstract: There is an urgent need to develop novel
Mycobacterium tuberculosis (Mtb) drugs that are active against drug
resistant bacteria but, more importantly, kill persistent bacteria. Our
study structured based on integrated analysis of metabolic pathways,
small molecule screening and similarity Search in PubChem
Database. Metabolic analysis approaches based on Unified weighted
used for potent target selection. Our results suggest that pantothenate
synthetase (panC) and and 3-methyl-2-oxobutanoate hydroxymethyl
transferase (panB) as a appropriate drug targets. In our study, we
used pantothenate synthetase because of existence inhibitors. We
have reported the discovery of new antitubercular compounds
through ligand based approaches using computational tools.
Abstract: Whereas in the third generation nuclear reactors,
dimensions of core and also the kind of coolant and enrichment
percent of fuel have significantly changed than the second
generation, therefore in this article the aim is based on a
comparative investigation between two same power reactors of
second and third generations, that the neutronic parameters of both
reactors such as: K∞, Keff and its details and thermal hydraulic
parameters such as: power density, specific power, volumetric heat
rate, released power per fuel volume unit, volume and mass of clad
and fuel (consisting fissile and fertile fuels), be calculated and
compared together. By this comparing the efficiency and
modification of third generation nuclear reactors than second
generation which have same power can be distinguished.
In order to calculate the cited parameters, some information
such as: core dimensions, the pitch of lattice, the fuel matter, the
percent of enrichment and the kind of coolant are used. For
calculating the neutronic parameters, a neutronic program entitled:
SIXFAC and also related formulas have been used. Meantime for
calculating the thermal hydraulic and other parameters, analytical
method and related formulas have been applied.