Symmetrical Analysis of a Six-Phase Induction Machine Under Fault Conditions

The operational behavior of a six-phase squirrel cage induction machine with faulted stator terminals is presented in this paper. The study is carried out using the derived mathematical model of the machine in the arbitrary reference frame. Tests are conducted on a 1 kW experimental machine. Steady-state and dynamic performance are analyzed for the machine unloaded and loaded conditions. The results shows that with one of the stator phases experiencing either an open- circuit or short circuit fault the machine still produces starting torque, albeit the running performance is significantly derated.




References:
[1] A. Yong-le, K. J. Maarten and A. D. Le Roux, "Novel Direct Flux and
Direct Torque Control of Six-Phase Induction Machine With Nearly
Square Air-Gap Flux Density", IEEE Transactions on Industry
Applications, Vol. 43, no. 6, November-December 2007.
[2] T. A. Lipo, "A d-q model for six-phase induction machines", in Proc.
Int. Conf. Electrical Machines, vol.2, pp. 860-867, 1980.
[3] G. K. Singh, "Multi-phase induction machine drive research" - a survey,
Electric Power Systems Research, vol. 61, no. 2, pp. 139-147, 2002.
[4] J. Apsley, S. Williamson, "Analysis of Multiphase Induction Machines
with Winding Faults", IEEE Transactions on Industry Applications,
VOL. 42, NO. 2 March-April 2006.
[5] P. C. Krause and C. H. Thomas,, "Simulation of Symmetrical Induction
Machinery", IEEE Trans. on Power Apparatus and Systems, Vol. PAS-
84, No. 4, pp. 1038-1049, 1965.
[6] M. O. Chee, "Dynamic Simulations of Induction Machine using
Matlab/Simulink", School Of Electrical and Computer engineering,
Purdue University, West Lafayette, Prentice hall, 1998.
[7] G. K. Singh, P. Vinay, "Analysis of a Multiphase Induction Machine
under Fault Condition in a Phase-Redundant A.C. Drive System".
Electric Power Components and Systems, 28: 6, 577 ÔÇö 590
[8] Y. Zhao and T. A. Lipo, "Modelling and Control of Multi-Phase
Induction Machine with Structural Unbalance", IEEE Transactions on
Energy Conversion, Vol. 11, No. 3, September 1996.
[9] R. S. Miranda, C. B. Jacobina, A. M. N. Lima, "Modelling and Analysis
of Six-Phase Induction Machine under Fault Condition", Power
Electronics Conference, 27 September-1 October 2009, COBEP -09,
Brazilian.
[10] P. C. Krause, O. Wasynczuk, S. D. Sudhoff, "Analysis of Electric
Machinery and Drive Systems", Second Edition, IEEE Press 2002.
[11] E. Levi, Recent Developments in High "Performance Variable-Speed
Multiphase" Induction Motor Drives, IEEE Trans. on Energy
Conversion, Vol. EC-11, No. 3, pp. 570-577, 2006.
[12] T. Wildi, "Electrical Machines, Drives, and Power Systems", Sixth
Edition, International Edition, Pearson Prentice Hall, 2004.
[13] J. R. Kianinezhad, B. N. Mobarakeh, L. Baghli, F. Betin, and G.
Capolino, "Modeling and Control of Six-Phase Symmetrical Induction
Machine Under Fault Condition Due to Open Phases," IEEE Trans.
Ind.Electron.VOL.55, Issue 5, pp 1966-1977, May 2008.