Realization of a Temperature Based Automatic Controlled Domestic Electric Boiling System

This paper presents a kind of analog circuit based
temperature control system, which is mainly composed by threshold
control signal circuit, synchronization signal circuit and trigger
pulse circuit. Firstly, the temperature feedback signal function is
realized by temperature sensor TS503F3950E. Secondly, the main
control circuit forms the cycle controlled pulse signal to control
the thyristor switching model. Finally two reverse paralleled
thyristors regulate the output power by their switching state. In
the consequence, this is a modernized and energy-saving domestic
electric heating system.




References:
[1] Xu Xianhai. ł(D). Nanjing: Southeast University, 2006.
[2] Yang, Q., Li, G. and Kang, X., 2008, July. Application of fuzzy PID
control in the heating system. In 2008 Chinese Control and Decision
Conference (pp. 2686-2690). IEEE.
[3] Wang Wei. DSPPID(D). Dalian Dalian Jiaotong University, 2009.
[4] Radakovic, Z. R., Milosevic, V. M. and Radakovic, S. B., 2002.
Application of temperature fuzzy controller in an indirect resistance
furnace. Applied Energy, 73(2), pp. 167-182.
[5] Wang Yalei. ŁDCS(D). Xi’an: Xi’an University of Science and
Technology.
[6] Davis, J. W., Brinton, R. K. and Wiseman, R. W., 1974 Index IEEE
Transactions on Industry Applications.
[7] Xu Kui. łŁŁ(D). Central South University, 2014.
[8] Bernard, J. I., 1939. The application of electric heating to domestic
hot-water supply system. Electrical Engineers, Journal of the
Institution of, 85(511), p. 1.
[9] Zhao shiming, Gao feng. ŁŁ(J). Water & Waste Water Engineering,
2009(02). [10] Abdelwahed S., Abdolkhani A., Abdullah M. A., Abe S., Abe S., Abe
T., Abedinpour S., Aboul-Zahab, E. M. and Aboushady, A. A., 2014.
2013 Combined Author Index IEEE Industry Applications Society
Publications. IEEE Transactions on Industry Applications, 50(1), p.
643.
[11] Forsyth S. L., 1957. Electric heating in the home. Electrical
Engineering, 76(2), pp. 118-123.
[12] Schiller P., 1951. Operational research in electricity distribution and
utilization. A review of progress. Proceedings of the IEE-Part I:
General, 98(112), pp.229-238.
[13] Grierson R. and Jackson F., 1948. The authors’ reply to the
discussions on Engineering principles applied to the design of
domestic water-heating installations of the solid-fuel/electric type.
Electrical Engineers-Part II: Power Engineering, Journal of the
Institution of, 95(44), pp. 201-204.