Abstract: In this paper, de Laval rotor system has been
characterized by a hinge model and its transient response numerically
treated for a dynamic solution. The effect of the ensuing non-linear
disturbances namely rub and breathing crack is numerically
simulated. Subsequently, three analysis methods: Orbit Analysis, Fast
Fourier Transform (FFT), and Wavelet Transform (WT) are
employed to extract features of the vibration signal of the faulty
system. An analysis of the system response orbits clearly indicates
the perturbations due to the rotor-to-stator contact. The sensitivities
of WT to the variation in system speed have been investigated by
Continuous Wavelet Transform (CWT). The analysis reveals that
features of crack, rubs and unbalance in vibration response can be
useful for condition monitoring. WT reveals its ability to detect nonlinear
signal, and obtained results provide a useful tool method for
detecting machinery faults.
Abstract: Rivers have transient storage or dead zones where
injected pollutants or solutes are entrapped for considerable period of
time, known as residence time, before being released into the main
flowing zones of rivers. In this study, a new empirical expression for
residence time, implementing genetic programming on published
dispersion data, has been derived. The proposed expression uses few
hydraulic and geometric characteristics of rivers which are normally
known to the authorities. When compared with some reported
expressions, based on various statistical indices, it can be concluded
that the proposed expression predicts the residence time of pollutants
in natural rivers more accurately.
Abstract: A solar receiver is designed for operation under
extremely uneven heat flux distribution, cyclic weather, and cloud
transient cycle conditions, which can include large thermal stress and
even receiver failure. In this study, the effect of different oil velocity
on convection coefficient factor and impact of wind velocity on local
Nusselt number by Finite Volume Method will be analyzed. This
study is organized to give an overview of the numerical modeling
using a MATLAB software, as an accurate, time efficient and
economical way of analyzing the heat transfer trends over stationary
receiver tube for different Reynolds number. The results reveal when
oil velocity is below 0.33m/s, the value of convection coefficient is
negligible at low temperature. The numerical graphs indicate that
when oil velocity increases up to 1.2 m/s, heat convection coefficient
increases significantly. In fact, a reduction in oil velocity causes a
reduction in heat conduction through the glass envelope. In addition,
the different local Nusselt number is reduced when the wind blows
toward the concave side of the collector and it has a significant effect
on heat losses reduction through the glass envelope.
Abstract: Increasingly complex modern power systems require
stability, especially for transient and small disturbances. Transient
stability plays a major role in stability during fault and large
disturbance. This paper compares a power system stabilizer (PSS)
and static Var compensator (SVC) to improve damping oscillation
and enhance transient stability. The effectiveness of a PSS connected
to the exciter and/or governor in damping electromechanical
oscillations of isolated synchronous generator was tested. The SVC
device is a member of the shunt FACTS (flexible alternating current
transmission system) family, utilized in power transmission systems.
The designed model was tested with a multi-machine system
consisting of four machines six bus, using MATLAB/SIMULINK
software. The results obtained indicate that SVC solutions are better
than PSS.
Abstract: In this article, we used the residual correction method
to deal with transient thermoelastic problems with a hollow spherical
region when the continuum medium possesses spherically isotropic
thermoelastic properties. Based on linear thermoelastic theory, the
equations of hyperbolic heat conduction and thermoelastic motion
were combined to establish the thermoelastic dynamic model with
consideration of the deformation acceleration effect and non-Fourier
effect under the condition of transient thermal shock. The approximate
solutions of temperature and displacement distributions are obtained
using the residual correction method based on the maximum principle
in combination with the finite difference method, making it easier and
faster to obtain upper and lower approximations of exact solutions.
The proposed method is found to be an effective numerical method
with satisfactory accuracy. Moreover, the result shows that the effect
of transient thermal shock induced by deformation acceleration is
enhanced by non-Fourier heat conduction with increased peak stress.
The influence on the stress increases with the thermal relaxation time.
Abstract: The growth in the demand of electrical energy is
leading to load on the Power system which increases the occurrence
of frequent oscillations in the system. The reason for the oscillations
is due to the lack of damping torque which is required to dominate
the disturbances of Power system. By using FACT devices, such as
Unified Power Flow Controller (UPFC) can control power flow,
reduce sub-synchronous resonances and increase transient stability.
Hence, UPFC is used to damp the oscillations occurred in Power
system. This research focuses on adapting the neuro fuzzy controller
for the UPFC design by connecting the infinite bus (SMIB - Single
machine Infinite Bus) to a linearized model of synchronous machine
(Heffron-Phillips) in the power system. This model gains the
capability to improve the transient stability and to damp the
oscillations of the system.
Abstract: The reheating furnace is used to reheat the steel slabs
before the hot-rolling process. The supported system includes the
stationary/moving beams, and the skid buttons which block some
thermal radiation transmitted to the bottom of the slabs. Therefore, it is
important to analyze the steel slab temperature distribution during the
heating period. A three-dimensional mathematical transient heat
transfer model for the prediction of temperature distribution within the
slab has been developed. The effects of different skid button height
(H=60mm, 90mm, and 120mm) and different gap distance between
two slabs (S=50mm, 75mm, and 100mm) on the slab skid mark
formation and temperature profiles are investigated. Comparison with
the in-situ experimental data from Steel Company in Taiwan shows
that the present heat transfer model works well for the prediction of
thermal behavior of the slab in the reheating furnace. It is found that
the skid mark severity decreases with an increase in the skid button
height. The effect of gap distance is important only for the slab edge
planes, while it is insignificant for the slab central planes.
Abstract: Radiative heat transfer in participating medium was
carried out using the finite volume method. The radiative transfer
equations are formulated for absorbing and anisotropically scattering
and emitting medium. The solution strategy is discussed and the
conditions for computational stability are conferred. The equations
have been solved for transient radiative medium and transient
radiation incorporated with transient conduction. Results have been
obtained for irradiation and corresponding heat fluxes for both the
cases. The solutions can be used to conclude incident energy and
surface heat flux. Transient solutions were obtained for a slab of heat
conducting in slab and by thermal radiation. The effect of heat
conduction during the transient phase is to partially equalize the
internal temperature distribution. The solution procedure provides
accurate temperature distributions in these regions. A finite volume
procedure with variable space and time increments is used to solve
the transient radiation equation. The medium in the enclosure
absorbs, emits, and anisotropically scatters radiative energy. The
incident radiations and the radiative heat fluxes are presented in
graphical forms. The phase function anisotropy plays a significant
role in the radiation heat transfer when the boundary condition is
non-symmetric.
Abstract: This paper describes how to dimension the electric
components of a 48V hybrid system considering real customer use.
Furthermore, it provides information about savings in energy and
CO2 emissions by a customer-tailored 48V hybrid. Based on measured customer profiles, the electric units such as the
electric motor and the energy storage are dimensioned. Furthermore,
the CO2 reduction potential in real customer use is determined
compared to conventional vehicles. Finally, investigations are carried
out to specify the topology design and preliminary considerations in
order to hybridize a conventional vehicle with a 48V hybrid system.
The emission model results from an empiric approach also taking into
account the effects of engine dynamics on emissions. We analyzed
transient engine emissions during representative customer driving
profiles and created emission meta models. The investigation showed
a significant difference in emissions when simulating realistic
customer driving profiles using the created verified meta models
compared to static approaches which are commonly used for vehicle
simulation.
Abstract: In most existing buildings in hot climate, cooling
loads lead to high primary energy consumption and consequently
high CO2 emissions. These can be substantially decreased with
integrated renewable energy systems. Kuwait is characterized by its
dry hot long summer and short warm winter. Kuwait receives annual
total radiation more than 5280 MJ/m2 with approximately 3347 h of
sunshine. Solar energy systems consist of PV modules and parabolic
trough collectors are considered to satisfy electricity consumption,
domestic water heating, and cooling loads of an existing building.
This paper presents the results of an extensive program of energy
conservation and energy generation using integrated photovoltaic
(PV) modules and Parabolic Trough Collectors (PTC). The program
conducted on an existing institutional building intending to convert it
into a Net-Zero Energy Building (NZEB) or near net Zero Energy
Building (nNZEB). The program consists of two phases; the first
phase is concerned with energy auditing and energy conservation
measures at minimum cost and the second phase considers the
installation of photovoltaic modules and parabolic trough collectors.
The 2-storey building under consideration is the Applied Sciences
Department at the College of Technological Studies, Kuwait. Single
effect lithium bromide water absorption chillers are implemented to
provide air conditioning load to the building. A numerical model is
developed to evaluate the performance of parabolic trough collectors
in Kuwait climate. Transient simulation program (TRNSYS) is
adapted to simulate the performance of different solar system
components. In addition, a numerical model is developed to assess
the environmental impacts of building integrated renewable energy
systems. Results indicate that efficient energy conservation can play
an important role in converting the existing buildings into NZEBs as
it saves a significant portion of annual energy consumption of the
building. The first phase results in an energy conservation of about
28% of the building consumption. In the second phase, the integrated
PV completely covers the lighting and equipment loads of the
building. On the other hand, parabolic trough collectors of optimum
area of 765 m2 can satisfy a significant portion of the cooling load,
i.e about73% of the total building cooling load. The annual avoided
CO2 emission is evaluated at the optimum conditions to assess the
environmental impacts of renewable energy systems. The total annual
avoided CO2 emission is about 680 metric ton/year which confirms
the environmental impacts of these systems in Kuwait.
Abstract: In this paper numerical studies have been carried out
to examine the pre-ignition flow features of high-performance solid
propellant rocket motors with two different port geometries but with
same propellant loading density. Numerical computations have been
carried out using a validated 3D, unsteady, 2nd-order implicit, SST k-
ω turbulence model. In the numerical study, a fully implicit finite
volume scheme of the compressible, Reynolds-Averaged, Navier-
Stokes equations is employed. We have observed from the numerical
results that in solid rocket motors with highly loaded propellants
having divergent port geometry the hot igniter gases can create preignition
pressure oscillations leading to thrust oscillations due to the
flow unsteadiness and recirculation. We have also observed that the
igniter temperature fluctuations are diminished rapidly thereby
reaching the steady state value faster in the case of solid propellant
rocket motors with convergent port than the divergent port
irrespective of the igniter total pressure. We have concluded that the
prudent selection of the port geometry, without altering the propellant
loading density, for damping the total temperature fluctuations within
the motor is a meaningful objective for the suppression and control of
instability and/or thrust oscillations often observed in solid propellant
rocket motors with non-uniform port geometry.
Abstract: Photovoltaic (PV) power generation systems, mainly
small scale, are rapidly being deployed in Jordan. The impact of these
systems on the grid has not been studied or analyzed. These systems
can cause many technical problems such as reverse power flows and
voltage rises in distribution feeders, and real and reactive power
transients that affect the operation of the transmission system. To
fully understand and address these problems, extensive research,
simulation, and case studies are required. To this end, this paper
studies the cloud shadow effect on the power generation of a ground
mounted PV system installed at the test field of the Renewable
Energy Center at the Applied Science University.
Abstract: The LSTF experiment simulating the SGTR accident at
the Mihama Unit-2 reactor is analyzed using the RELAP5/MOD3.3
code. In the accident, and thus in the experiment, the ECC water was
injected not only into the cold legs but into the upper plenum. Overall
transients during the experiment such as pressures and fluid
temperatures are simulated well by the code. The cold-leg fluid
temperatures are shown to decrease if the upper plenum injection
system is connected to the cold leg. It is found that the cold-leg fluid
temperatures also decrease if the upper-plenum injection is not used
and the cold-leg injection alone is actuated.
Abstract: The recent interest in alternative and renewable
energy systems results in increased installed capacity ratio of such
systems in total energy production of the world. Specifically, Wind
Energy Conversion Systems (WECS) draw significant attention
among possible alternative energy options, recently. On the contrary
of the positive points of penetrating WECS in all over the world in
terms of environment protection, energy independence of the
countries, etc., there are significant problems to be solved for the grid
connection of large scale WECS. The reactive power regulation,
voltage variation suppression, etc. can be presented as major issues to
be considered in this regard. Thus, this paper evaluates the
application of a Static VAr Compensator (SVC) unit for the reactive
power regulation and operation continuity of WECS during a fault
condition. The system is modeled employing the IEEE 13 node test
system. Thus, it is possible to evaluate the system performance with
an overall grid simulation model close to real grid systems. The
overall simulation model is developed in
MATLAB/Simulink/SimPowerSystems® environments and the
obtained results effectively match the target of the provided study.
Abstract: A solution methodology without using integral
transformation is proposed to develop analytical solutions for
transient heat conduction in nonuniform hollow cylinders with
time-dependent boundary condition at the outer surface. It is shown
that if the thermal conductivity and the specific heat of the medium
are in arbitrary polynomial function forms, the closed solutions of the
system can be developed. The influence of physical properties on the
temperature distribution of the system is studied. A numerical
example is given to illustrate the efficiency and the accuracy of the
solution methodology.
Abstract: This paper presents the design process of a high
performance 3-phase 3.7 kW 2-pole line start permanent magnet
synchronous motor for pumping system. A method was proposed to
study the starting torque characteristics considering line start with
high inertia load. A d-q model including cage was built to study the
synchronization capability. Time-stepping finite element method
analysis was utilized to accurately predict the dynamic and transient
performance, efficiency, starting current, speed curve and etc.
Considering the load torque of pumps during starting stage, the rotor
bar was designed with minimum demagnetization of permanent
magnet caused by huge starting current.
Abstract: The effects of flame-holder position, the ratio of flame
holder diameter to combustion chamber diameter and injection angle
on fuel propulsive droplets sizing and effective mass fraction have
been studied by a cold flow. We named the mass of fuel vapor inside
the flammability limit as the effective mass fraction. An empty
cylinder as well as a flame-holder which are a simulator for duct
combustion has been considered. The airflow comes into the cylinder
from one side and injection operation will be done by four nozzles
which are located on the entrance of cylinder. To fulfill the
calculations a modified version of KIVA-3V code which is a
transient, three-dimensional, multiphase, multi component code for
the analysis of chemically reacting flows with sprays, is used.
Abstract: High Voltage Direct Current (HVDC) power
transmission is employed to move large amounts of electric power.
There are several possibilities to enhance the transient stability in a
power system. One adequate option is by using the high
controllability of the HVDC if HVDC is available in the system. This
paper presents a control technique for HVDC to enhance the transient
stability. The strategy controls the power through the HVDC to help
make the system more transient stable during disturbances. Loss of
synchronism is prevented by quickly producing sufficient
decelerating energy to counteract accelerating energy gained during.
In this study, the power flow in the HVDC link is modulated with the
addition of an auxiliary signal to the current reference of the rectifier
firing angle controller. This modulation control signal is derived from
speed deviation signal of the generator utilizing a PD controller; the
utilization of a PD controller is suitable because it has the property of
fast response. The effectiveness of the proposed controller is
demonstrated with a SMIB test system.
Abstract: The numerical simulation has made tremendous
advances in investigating the blood flow phenomenon through elastic
arteries. Such study can be useful in demonstrating the disease
progression and hemodynamics of cardiovascular diseases such as
atherosclerosis. In the present study, patient specific case diagnosed
with partially stenosed complete right ICA and normal left carotid
bifurcation without any atherosclerotic plaque formation is
considered. 3D patient specific carotid bifurcation model is generated
based on CT scan data using MIMICS-4.0 and numerical analysis is
performed using FSI solver in ANSYS-14.5. The blood flow is
assumed to be incompressible, homogenous and Newtonian, while
the artery wall is assumed to be linearly elastic. The two-way
sequentially coupled transient FSI analysis is performed using FSI
solver for three pulse cycles. The hemodynamic parameters such as
flow pattern, Wall Shear Stress, pressure contours and arterial wall
deformation are studied at the bifurcation and critical zones such as
stenosis. The variation in flow behavior is studied throughout the
pulse cycle. Also, the simulation results reveal that there is a
considerable increase in the flow behavior in stenosed carotid in
contrast to the normal carotid bifurcation system. The investigation
also demonstrates the disturbed flow pattern especially at the
bifurcation and stenosed zone elevating the hemodynamics,
particularly during peak systole and later part of the pulse cycle. The
results obtained agree well with the clinical observation and
demonstrates the potential of patient specific numerical studies in
prognosis of disease progression and plaque rupture.
Abstract: This paper presents a novel integrated hybrid
approach for fault diagnosis (FD) of nonlinear systems. Unlike most
FD techniques, the proposed solution simultaneously accomplishes
fault detection, isolation, and identification (FDII) within a unified
diagnostic module. At the core of this solution is a bank of adaptive
neural parameter estimators (NPE) associated with a set of singleparameter
fault models. The NPEs continuously estimate unknown
fault parameters (FP) that are indicators of faults in the system. Two
NPE structures including series-parallel and parallel are developed
with their exclusive set of desirable attributes. The parallel scheme is
extremely robust to measurement noise and possesses a simpler, yet
more solid, fault isolation logic. On the contrary, the series-parallel
scheme displays short FD delays and is robust to closed-loop system
transients due to changes in control commands. Finally, a fault
tolerant observer (FTO) is designed to extend the capability of the
NPEs to systems with partial-state measurement.