Abstract: Renewable energy sources and distributed power generation units already have an important role in electrical power generation. A mixture of different technologies penetrating the electrical grid, adds complexity in the management of distribution networks. High penetration of distributed power generation units creates node over-voltages, huge power losses, unreliable power management, reverse power flow and congestion. This paper presents an optimization algorithm capable of reducing congestion and power losses, both described as a function of weighted sum. Two factors that describe congestion are being proposed. An upgraded selective particle swarm optimization algorithm (SPSO) is used as a solution tool focusing on the technique of network reconfiguration. The upgraded SPSO algorithm is achieved with the addition of a heuristic algorithm specializing in reduction of power losses, with several scenarios being tested. Results show significant improvement in minimization of losses and congestion while achieving very small calculation times.
Abstract: Power distribution circuits undergo frequent network
topology changes that are often left undocumented. As a result, the
documentation of a circuit’s connectivity becomes inaccurate with
time. The lack of reliable circuit connectivity information is one of the
biggest obstacles to model, monitor, and control modern distribution
systems. To enhance the reliability and efficiency of electric power
distribution systems, the circuit’s connectivity information must be
updated periodically. This paper focuses on one critical component of
a distribution circuit’s topology - the secondary transformer to phase
association. This topology component describes the set of phase lines
that feed power to a given secondary transformer (and therefore a
given group of power consumers). Finding the documentation of this
component is call Phase Identification, and is typically performed
with physical measurements. These measurements can take time
lengths on the order of several months, but with supervised learning,
the time length can be reduced significantly. This paper compares
several such methods applied to Phase Identification for a large
range of real distribution circuits, describes a method of training
data selection, describes preprocessing steps unique to the Phase
Identification problem, and ultimately describes a method which
obtains high accuracy (> 96% in most cases, > 92% in the worst
case) using only 5% of the measurements typically used for Phase
Identification.
Abstract: Smart grid is a term used to describe the next generation
power grid. New challenges such as integration of renewable and
decentralized energy sources, the requirement for continuous grid
estimation and optimization, as well as the use of two-way flows
of energy have been brought to the power gird. In order to achieve
efficient, reliable, sustainable, as well as secure delivery of electric
power more and more information and communication technologies
are used for the monitoring and the control of power grids.
Consequently, the need for cybersecurity is dramatically increased
and has converged into several standards which will be presented
here. These standards for the smart grid must be designed to
satisfy both performance and reliability requirements. An in depth
investigation of the effect of retrospectively embedded security in
existing grids on it’s dynamic behavior is required. Therefore, a
retrofitting plan for existing meters is offered, and it’s performance
in a test low voltage microgrid is investigated. As a result of this,
integration of security measures into measurement architectures of
smart grids at the design phase is strongly recommended.
Abstract: This paper presents an improved Direct Power Control (DPC) scheme applied to the multilevel inverter that forms a Distributed Generation Unit (DGU). This paper demonstrates the performance of active and reactive power injected by the DGU to the smart grid. The DPC is traditionally operated by the hysteresis controller with the Space Vector Modulation (SVM) which is applied on the 2-level inverters or 3-level inverters. In this paper, the DPC is operated by the PI controller with the Phase-Disposition Pulse Width Modulation (PD-PWM) applied to the 5-level diode clamped inverter. The new combination of the DPC, PI controller, PD-PWM and multilevel inverter proves that its performance is much better than the conventional hysteresis-SVM based DPC. Simulations results have been presented to validate the performance of the suggested control scheme in the grid-connected mode.
Abstract: A smart grid is an emerging technology in the power delivery system which provides an intelligent, self-recovery and homeostatic grid in delivering power to the users. Smart grid communication network provides transmission capacity for information transformation within the connected nodes in the network, in favor of functional and operational needs. In the electric grids communication network delay is based on choosing the appropriate technology and the types of devices enforced. In distinction, the combination of IEEE 802.16 based WiMAX and IEEE 802.11 based WiFi technologies provides improved coverage and gives low delay performances to meet the smart grid needs. By incorporating this method in Wide Area Monitoring System (WAMS) and Advanced Metering Infrastructure (AMI) the performance of the smart grid will be considerably improved. This work deals with the implementation of WiMAX-WLAN integrated network architecture for WAMS and AMI in the smart grid.
Abstract: More than half of the urban population in Romania lives today in residential buildings made out of large prefabricated reinforced concrete panels. Since their initial design was made in the 1960’s, these housing units are now being technically and morally outdated, consuming large amounts of energy for heating, cooling, ventilation and lighting, while failing to meet the needs of the contemporary life-style. Due to their widespread use, the design of a system that improves their energy efficiency would have a real impact, not only on the energy consumption of the residential sector, but also on the quality of life that it offers. Furthermore, with the transition of today’s existing power grid to a “smart grid”, buildings could become an active element for future electricity networks by contributing in micro-generation and energy storage. One of the most addressed issues today is to find locally adapted strategies that can be applied considering the 20-20-20 EU policy criteria and to offer sustainable and innovative solutions for the cost-optimal energy performance of buildings adapted on the existing local market. This paper presents a possible adaptive design scenario towards sustainable retrofitting of these housing units. The apartments are transformed in order to meet the current living requirements and additional extensions are placed on top of the building, replacing the unused roof space, acting not only as housing units, but as active solar energy collection systems. An adaptive building envelope is ensured in order to achieve overall air-tightness and an elevator system is introduced to facilitate access to the upper levels.
Abstract: In the standards of IEC 60076-2 and IEC 60076-7, three different hot-spot temperature estimation methods are suggested. In this study, the algorithms which used in hot-spot temperature calculations are analyzed by comparing the algorithms with the results of an experimental set-up made by a Transformer Monitoring System (TMS) in use. In tested system, TMS uses only top oil temperature and load ratio for hot-spot temperature calculation. And also, it uses some constants from standards which are on agreed statements tables. During the tests, it came out that hot-spot temperature calculation method is just making a simple calculation and not uses significant all other variables that could affect the hot-spot temperature.
Abstract: Smart metering and demand response are gaining
ground in industrial and residential applications. Smart Appliances
have been given concern towards achieving Smart home. The success
of Smart grid development relies on the successful implementation of
Information and Communication Technology (ICT) in power sector.
Smart Appliances have been the technology under development and
many new contributions to its realization have been reported in the
last few years. The role of ICT here is to capture data in real time,
thereby allowing bi-directional flow of information/data between
producing and utilization point; that lead a way for the attainment of
Smart appliances where home appliances can communicate between
themselves and provide a self-control (switch on and off) using the
signal (information) obtained from the grid. This paper depicts the
background on ICT for smart appliances paying a particular attention
to the current technology and identifying the future ICT trends for
load monitoring through which smart appliances can be achieved to
facilitate an efficient smart home system which promote demand
response program. This paper grouped and reviewed the recent
contributions, in order to establish the current state of the art and
trends of the technology, so that the reader can be provided with a
comprehensive and insightful review of where ICT for smart
appliances stands and is heading to. The paper also presents a brief
overview of communication types, and then narrowed the discussion
to the load monitoring (Non-intrusive Appliances Load Monitoring
‘NALM’). Finally, some future trends and challenges in the further
development of the ICT framework are discussed to motivate future
contributions that address open problems and explore new
possibilities.
Abstract: Nowadays, Photovoltaic-PV Farms/ Parks and large
PV-Smart Grid Interface Schemes are emerging and commonly
utilized in Renewable Energy distributed generation. However, PVhybrid-
Dc-Ac Schemes using interface power electronic converters
usually has negative impact on power quality and stabilization of
modern electrical network under load excursions and network fault
conditions in smart grid. Consequently, robust FACTS based
interface schemes are required to ensure efficient energy utilization
and stabilization of bus voltages as well as limiting switching/fault
onrush current condition. FACTS devices are also used in smart grid-
Battery Interface and Storage Schemes with PV-Battery Storage
hybrid systems as an elegant alternative to renewable energy
utilization with backup battery storage for electric utility energy and
demand side management to provide needed energy and power
capacity under heavy load conditions. The paper presents a robust
interface PV-Li-Ion Battery Storage Interface Scheme for
Distribution/Utilization Low Voltage Interface using FACTS
stabilization enhancement and dynamic maximum PV power tracking
controllers.
Digital simulation and validation of the proposed scheme is done
using MATLAB/Simulink software environment for Low Voltage-
Distribution/Utilization system feeding a hybrid Linear-Motorized
inrush and nonlinear type loads from a DC-AC Interface VSC-6-
pulse Inverter Fed from the PV Park/Farm with a back-up Li-Ion
Storage Battery.
Abstract: Smart grid is a new approach for electric power grid that uses information and communications technology to control the electric power grid. Smart grid provides real-time control of the electric power grid, controlling the direction of power flow or time of the flow. Control devices are installed on the power lines of the electric power grid to implement smart grid. The number of the control devices should be determined, in relation with the area one control device covers and the cost associated with the control devices. One approach to determine the number of the control devices is to use the data on the surplus power generated by home solar generators. In current implementations, the surplus power is sent all the way to the power plant, which may cause power loss. To reduce the power loss, the surplus power may be sent to a control device and sent to where the power is needed from the control device. Under assumption that the control devices are installed on a lattice of equal size squares, our goal is to figure out the optimal spacing between the control devices, where the power sharing area (the area covered by one control device) is kept small to avoid power loss, and at the same time the power sharing area is big enough to have no surplus power wasted. To achieve this goal, a simulation using landscape ecology method is conducted on a sample area. First an aerial photograph of the land of interest is turned into a mosaic map where each area is colored according to the ratio of the amount of power production to the amount of power consumption in the area. The amount of power consumption is estimated according to the characteristics of the buildings in the area. The power production is calculated by the sum of the area of the roofs shown in the aerial photograph and assuming that solar panels are installed on all the roofs. The mosaic map is colored in three colors, each color representing producer, consumer, and neither. We started with a mosaic map with 100 m grid size, and the grid size is grown until there is no red grid. One control device is installed on each grid, so that the grid is the area which the control device covers. As the result of this simulation we got 350m as the optimal spacing between the control devices that makes effective use of the surplus power for the sample area.