Abstract: An investigation has been presented to analyze the
effect of internal heat source on the onset of Hadley-Prats flow in
a horizontal fluid saturated porous medium. We examine a better
understanding of the combined influence of the heat source and mass
flow effect by using linear stability analysis. The resultant eigenvalue
problem is solved by using shooting and Runga-Kutta methods for
evaluate critical thermal Rayleigh number with respect to various
flow governing parameters. It is identified that the flow is switch from
stabilizing to destabilizing as the horizontal thermal Rayleigh number
is enhanced. The heat source and mass flow increases resulting a
stronger destabilizing effect.
Abstract: Mass flow measurement is the basis of most technoeconomic
formulations in the chemical industry. This calls for
reliable and accurate detection of mass flow. Flow measurement
laboratory experiments were conducted using various instruments.
These consisted of orifice plates, various sized rotameters, wet gas
meter and soap bubble meter. This work was aimed at evaluating
appropriate operating conditions and accuracy of the aforementioned
devices. The experimental data collected were compared to
theoretical predictions from Bernoulli’s equation and calibration
curves supplied by the instrument’s manufacturers. The results
obtained showed that rotameters were more reliable for measuring
high and low flow rates; while soap-bubble meters and wet-gas
meters were found to be suitable for measuring low flow rates. The
laboratory procedures and findings of the actual work can assist
engineering students and professionals in conducting their flow
measurement laboratory test work.
Abstract: The counter flow solar air heaters, with four
transverse fins and wire mesh layers are constructed and investigated
experimentally for thermal efficiency at a geographic location of
Cyprus in the city of Famagusta. The absorber plate is replaced by
sixteen steel wire mesh layers, 0.18 x 0.18cm in cross section
opening and a 0.02cm in diameter. The wire mesh layers arranged in
three groups, first and second include 6 layers, while the third include
4 layers. All layers fixed in the duct parallel to the glazing and each
group separated from the others by wood frame thickness of 0.5cm to
reduce the pressure drop. The transverse fins arranged in a way to
force the air to flow through the bed like eight letter path with flow
depth 3cm. The proposed design has increased the heat transfer rate,
but on other hand causes a high pressure drop. The obtained results
show that, for air mass flow rate range between 0.011-0.036kg/s, the
thermal efficiency increases with increasing the air mass flow. The
maximum efficiency obtained is 65.6% for the mass flow rate of
0.036kg/s. Moreover, the temperature difference between the outlet
flow and the ambient temperature, ΔT, reduces as the air mass flow
rate increase. The maximum difference between the outlet and
ambient temperature obtained was 43°C for double pass for minimum
mass flow rate of 0.011kg/s. Comparison with a conventional solar
air heater collector shows a significantly development in the thermal
efficiency.