Abstract: There-s a lack in understanding the indoor climate of Malaysian residential. The assumption of traditional house could
provide the best indoor environment is too good to be true. This research is to understand indoor environment in three types of
Malaysian residential and thermo recorder TR72Ui were placed in
indoor spaces for measurement. There are huge differences of indoor
environment between housing types, and building material helps to control indoor climate. Traditional house indoor climate was similar to
the outdoor. Temperature in the bedroom of terrace and town houses were slightly higher than the living room. Indoor temperature was 2oC
lower in the rainy season than the hot season. It was hard to control
indoor humidity level in traditional house compared with terrace and
town house. As for conclusion, town house provides the best thermal
environment to the building occupants and can be improved with good
roof insulation.
Abstract: The use of 3D computer-aided design (CAD) models
to support construction project planning has been increasing in the
previous year. 3D CAD models reveal more planning ideas by
visually showing the construction site environment in different stages
of the construction process. Using 3D CAD models together with
scheduling software to prepare construction plan can identify errors
in process sequence and spatial arrangement, which is vital to the
success of a construction project. A number of 4D (3D plus time)
CAD tools has been developed and utilized in different construction
projects due to the awareness of their importance. Virtual prototyping
extends the idea of 4D CAD by integrating more features for
simulating real construction process. Virtual prototyping originates
from the manufacturing industry where production of products such
as cars and airplanes are virtually simulated in computer before they
are built in the factory. Virtual prototyping integrates 3D CAD,
simulation engine, analysis tools (like structural analysis and
collision detection), and knowledgebase to streamline the whole
product design and production process. In this paper, we present the
application of a virtual prototyping software which has been used in
a few construction projects in Hong Kong to support construction
project planning. Specifically, the paper presents an implementation
of virtual prototyping in a residential building project in Hong Kong.
The applicability, difficulties and benefits of construction virtual
prototyping are examined based on this project.
Abstract: GFRG(Glass Fiber Reinforced Gypsum) wall is a green product which can erect a building fast in prefabricated method, but its application to high-rise residential buildings is limited for its poor lateral stiffness. This paper has proposed a modification to GFRG walls structure to increase its lateral stiffness, which aiming to erect small high-rise residential buildings as load-bearing walls. The elastic finite element analysis to it has shown the lateral deformation feature and the distributions of the axial force and the shear force. The analysis results show that the new GFRG reinforced concrete wall can be used for small high-rise residential buildings.
Abstract: Solar shading designs are important for reduction of building energy consumption and improvement of indoor thermal environment. This paper carried out a number of building simulations for evaluation of the energy performance of different shading devices based on incremental costs. The results show that movable shading devices lower incremental costs by up to 50% compared with fixed ones for the same building energy efficiency for residential buildings, and wing panel shadings are much more suitable in commercial buildings than baring screen ones and overhangs for commercial buildings.
Abstract: The increasing demand for sufficient and clean
energy forces industrial and service companies to align their strategies towards efficient consumption. This trend refers also to the
residential building sector. There, large amounts of energy consumption are caused by house and facility heating. Many of the
operated hot water heating systems lack hydraulic balanced working
conditions for heat distribution and –transmission and lead to
inefficient heating. Through hydraulic balancing of heating systems,
significant energy savings for primary and secondary energy can be
achieved. This paper addresses the use of KNX-technology (Smart
Buildings) in residential buildings to ensure a dynamic adaption of
hydraulic system's performance, in order to increase the heating
system's efficiency. In this paper, the procedure of heating system
segmentation into hydraulically independent units (meshes) is
presented. Within these meshes, the heating valve are addressed and
controlled by a central facility server. Feasibility criteria towards
such drivers will be named. The dynamic hydraulic balance is
achieved by positioning these valves according to heating loads, that
are generated from the temperature settings in the corresponding
rooms. The energetic advantages of single room heating control
procedures, based on the application FacilityManager, is presented.
Abstract: The building sector is the largest energy consumer and
CO2 emitter in the European Union (EU) and therefore the active
reduction of energy consumption and elimination of energy wastage
are among the main goals in it. Healthy housing and energy
efficiency are affected by many factors which set challenges to
monitoring, control and research of indoor air quality (IAQ) and
energy consumption, especially in old buildings. These challenges
include measurement and equipment costs, for example.
Additionally, the measurement results are difficult to interpret and
their usage in the ventilation control is also limited when taking into
account the energy efficiency of housing at the same time. The main
goal of this study is to develop a cost-effective building monitoring
and control system especially for old buildings. The starting point or
keyword of the development process is a wireless system; otherwise
the installation costs become too high. As the main result, this paper
describes an idea of a wireless building monitoring and control
system. The first prototype of the system has been installed in 10
residential buildings and in 10 school buildings located in the City of
Kuopio, Finland.
Abstract: Explosions may cause intensive damage to buildings
and sometimes lead to total and progressive destruction. Pressures
induced by explosions are one of the most destructive loads a
structure may experience. While designing structures for great
explosions may be expensive and impractical, engineers are looking
for methods for preventing destructions resulted from explosions. A
favorable structural system is a system which does not disrupt totally
due to local explosion, since such structures sustain less loss in
comparison with structural ones which really bear the load and
suddenly disrupt. Designing and establishing vital and necessary
installations in a way that it is resistant against direct hit of bomb and
rocket is not practical, economical, or expedient in many cases,
because the cost of construction and installation with such
specifications is several times more than the total cost of the related
equipment.
Abstract: The principle concern of this paper is to determine the
impact of solar absorption coefficient of external wall on building
energy consumption. Simulations were carried out on a typical
residential building by using the simulation Toolkit DeST-h. Results
show that reducing solar absorption coefficient leads to a great
reduction in building energy consumption and thus light-colored
materials are suitable.
Abstract: Certifications such as the Passive House Standard aim to reduce the final space heating energy demand of residential buildings. Space conditioning, notably heating, is responsible for nearly 70% of final residential energy consumption in Europe. There is therefore significant scope for the reduction of energy consumption through improvements to the energy efficiency of residential buildings. However, these certifications totally overlook the energy embodied in the building materials used to achieve this greater operational energy efficiency. The large amount of insulation and the triple-glazed high efficiency windows require a significant amount of energy to manufacture. While some previous studies have assessed the life cycle energy demand of passive houses, including their embodied energy, these rely on incomplete assessment techniques which greatly underestimate embodied energy and can lead to misleading conclusions. This paper analyses the embodied and operational energy demands of a case study passive house using a comprehensive hybrid analysis technique to quantify embodied energy. Results show that the embodied energy is much more significant than previously thought. Also, compared to a standard house with the same geometry, structure, finishes and number of people, a passive house can use more energy over 80 years, mainly due to the additional materials required. Current building energy efficiency certifications should widen their system boundaries to include embodied energy in order to reduce the life cycle energy demand of residential buildings.
Abstract: This study was investigated on sampling and
analyzing water quality in water reservoir & water tower installed in
two kind of residential buildings and school facilities. Data of water
quality was collected for correlation analysis with frequency of
sanitization of water reservoir through questioning managers of
building about the inspection charts recorded on equipment for water
reservoir. Statistical software packages (SPSS) were applied to the
data of two groups (cleaning frequency and water quality) for
regression analysis to determine the optimal cleaning frequency of
sanitization. The correlation coefficient (R) in this paper represented
the degree of correlation, with values of R ranging from +1 to -1.After
investigating three categories of drinking water users; this study found
that the frequency of sanitization of water reservoir significantly
influenced the water quality of drinking water. A higher frequency of
sanitization (more than four times per 1 year) implied a higher quality
of drinking water. Results indicated that sanitizing water reservoir &
water tower should at least twice annually for achieving the aim of
safety of drinking water.
Abstract: In this paper a polymer electrolyte membrane (PEM)
fuel cell power system including burner, steam reformer, heat
exchanger and water heater has been considered to meet the
electrical, heating, cooling and domestic hot water loads of
residential building which in Tehran. The system uses natural gas as
fuel and works in CHP mode. Design and operating conditions of a
PEM fuel cell system is considered in this study. The energy
requirements of residential building and the number of fuel cell
stacks to meet them have been estimated. The method involved
exergy analysis and entropy generation thorough the months of the
year. Results show that all the energy needs of the building can be
met with 12 fuel cell stacks at a nominal capacity of 8.5 kW. Exergy
analysis of the CHP system shows that the increase in the ambient air
temperature from 1oC to 40oC, will have an increase of entropy
generation by 5.73%.Maximum entropy generates for 15 hour in 15th
of June and 15th of July is estimated to amount at 12624 (kW/K).
Entropy generation of this system through a year is estimated to
amount to 1004.54 GJ/k.year.
Abstract: Structural redundancy is an interesting point in
seismic design of structures. Initially, the structural redundancy is
described as indeterminate degree of a system. Although many definitions are presented for redundancy in structures, recently the
definition of structural redundancy has been related to the configuration of structural system and the number of lateral load
transferring directions in the structure. The steel frames with infill walls are general systems in the constructing of usual residential buildings in some countries. It is
obviously declared that the performance of structures will be affected by adding masonry infill walls. In order to investigate the effect of
infill walls on the redundancy of the steel frame which constructed
with masonry walls, the components of redundancy including redundancy variation index, redundancy strength index and
redundancy response modification factor were extracted for the
frames with masonry infills. Several steel frames with typical storey number and various numbers of bays were designed and considered.
The redundancy of frames with and without infill walls was evaluated by proposed method. The results showed the presence of infill causes increase of redundancy.
Abstract: Sustainable energy usage has been recognized as one
of the important measure to increase the competitiveness of the
nation globally. Many strong emphases were given in the Ninth
Malaysia Plan (RMK9) to improve energy efficient especially to
government buildings. With this in view, a project to investigate the
potential of energy saving in selected building in Universiti Tun
Hussein Onn Malaysia (UTHM) was carried out. In this project, a
case study involving electric energy consumption of the academic
staff office building was conducted. The scope of the study include to
identify energy consumption in a selected building, to study energy
saving opportunities, to analyse cost investment in term of economic
and to identify users attitude with respect to energy usage. The
MS1525:2001, Malaysian Standard -Code of practice on energy
efficiency and use of renewable energy for non-residential buildings
was used as reference. Several energy efficient measures were
considered and their merits and priority were compared. Improving
human behavior can reduce energy consumption by 6% while
technical measure can reduce energy consumption by 44%. Two
economic analysis evaluation methods were applied; they are the
payback period method and net present value method.
Abstract: Nowadays, the earth is countered with serious problem
of air pollution. This problem has been started from the industrial
revolution and has been faster in recent years, so that leads the earth
to ecological and environmental disaster. One of its results is the
global warming problem and its related increase in global
temperature. The most important factors in air pollution especially in
urban environments are Automobiles and residential buildings that are
the biggest consumers of the fossil energies, so that if the residential
buildings as a big part of the consumers of such energies reduce their
consumption rate, the air pollution will be decreased. Since
Metropolises are the main centers of air pollution in the world,
assessment and analysis of efficient strategies in decreasing air
pollution in such cities, can lead to the desirable and suitable results
and can solve the problem at least in critical level. Tabriz city is one
of the most important metropolises in North west of Iran that about
two million people are living there. for its situation in cold dry
climate, has a high rate of fossil energies consumption that make air
pollution in its urban environment. These two factors, being both
metropolis and in cold dry climate, make this article try to analyze the
strategies of climatic design in old districts of the city and use them in
new districts of the future. These strategies can be used in this city
and other similar cities and pave the way to reduce energy
consumption and related air pollution to save whole world.
Abstract: Nowadays over-consumption of fossil energy in
buildings especially in residential buildings and also considering the
increase in populations, the crisis of energy shortage in a near future
is predictable. The recent performance of developed countries in
construction with the aim of decreasing fossil energies shows that
these countries have understood the incoming crisis and has taken
reasonable and basic actions in this regard. However, Iranian
architecture, with several thousands years of history, has acquired
and executed invaluable experiences in designing, adapting and
coordinating with the nature.
Architectural studies during the recent decades show that imitating
modern western architecture results in high energy wastage beside
the fact that it not reasonably adaptable and corresponded with the
habits and customs of people unlike the architecture in the past which
was compatible and adaptable with the climatic conditions and this
necessitates optimal using of renewable energies more than ever. This
paper studies problems of design, execution and living in today's
houses and reviews the characteristics of climatic elements paying
special attention to the performance of trombe wall and solar
greenhouse in traditional houses and offers some suggestions for
combining these two elements and a climatic strategy.
Abstract: The current study describes a multi-objective optimization technique for positioning of houses in a residential neighborhood. The main task is the placement of residential houses in a favorable configuration satisfying a number of objectives. Solving the house layout problem is a challenging task. It requires an iterative approach to satisfy design requirements (e.g. energy efficiency, skyview, daylight, roads network, visual privacy, and clear access to favorite views). These design requirements vary from one project to another based on location and client preferences. In the Gulf region, the most important socio-cultural factor is the visual privacy in indoor space. Hence, most of the residential houses in this region are surrounded by high fences to provide privacy, which has a direct impact on other requirements (e.g. daylight and direction to favorite views). This investigation introduces a novel technique to optimally locate and orient residential buildings to satisfy a set of design requirements. The developed technique explores the search space for possible solutions. This study considers two dimensional house planning problems. However, it can be extended to solve three dimensional cases.
Abstract: The phenomenon of global warming or climate
change has led to many environmental issues including higher
atmospheric temperatures, intense precipitation, increased
greenhouse gaseous emissions and increased indoor discomfort.
Studies have shown that bringing nature to the roof such as
constructing green roof and implementing high-reflective roof may
give positive impact in mitigating the effects of global warming and
in increasing thermal comfort sensation inside buildings. However,
no study has been conducted to compare both types of passive roof
treatments in Malaysia in order to increase thermal comfort in
buildings. Therefore, this study is conducted to investigate the effect
of green roof and white painted roof as passive roof treatment in
improving indoor comfort of Malaysian homes. This study uses an
experimental approach in which the measurements of temperatures
are conducted on the case study building. The measurements of
outdoor and indoor environments were conducted on the flat roof
with two different types of roof treatment that are green roof and
white roof. The measurement of existing black bare roof was also
conducted to act as a control for this study.
Abstract: In the territories where high-intensity
earthquakes are frequent is paid attention to the solving of the
seismic problems. In the paper are described two
computational model variants based on finite element method
of the construction with different subsoil simulation (rigid or
elastic subsoil) is used. For simulation and calculations
program system based on method final elements ANSYS was
used. Seismic responses calculations of residential building
structure were effected on loading characterized by
accelerogram for comparing with the responses spectra
method.
Abstract: According to the masonry standard the compressive
strength is basically dependent on factors such as the mortar strength
and the relative values of unit and mortar strength. However
interlocking brick has none or less use of mortar. Therefore there is a need to investigate the behavior of masonry walls using interlocking
bricks. In this study a series of tests have been conducted; physical
properties and compressive strength of brick units and masonry walls
were constructed from interlocking bricks and tested under constant
vertical load at different eccentricities. The purpose of the
experimental investigations is to obtain the force displacement curves, analyze the behavior of masonry walls. The results showed
that the brick is categorized as common brick (BS 3921:1985) and severe weathering grade (ASTM C62). The maximum compressive stress of interlocking brick wall is 3.6 N/mm2 and fulfilled the requirement of standard for residential building.
Abstract: A seismic isolation pad produced by utilizing the scrap
tire rubber which contains interleaved steel reinforcing cords has been
proposed. The steel cords are expected to function similar to the steel
plates used in conventional laminated rubber bearings. The scrap tire
rubber pad (STRP) isolator is intended to be used in low rise
residential buildings of highly seismic areas of the developing
countries. Experimental investigation was conducted on unbonded
STRP isolators, and test results provided useful information including
stiffness, damping values and an eventual instability of the isolation
unit. Finite element analysis (FE analysis) of STRP isolator was
carried out on properly bonded samples. These types of isolators
provide positive incremental force resisting capacity up to shear strain
level of 155%. This paper briefly discusses the force deformation
behavior of bonded STRP isolators including stability of the isolation
unit.