Abstract: The paper deals with the problems of the actual
behavior, failure mechanism and load-carrying capacity of the special
bolt connection developed and intended for the assembly connections
of truss main girders of perspective railway temporary steel bridges.
Within the framework of this problem solution, several types of
structural details of assembly joints have been considered as the
conceptual structural design. Based on the preliminary evaluation of
advantages or disadvantages of these ones, in principle two basic
structural configurations – so-called “tooth” and “splice-plate”
connections have been selected for the subsequent detailed
investigation. This investigation is mainly based on the experimental
verification of the actual behavior, strain and failure mechanism and
corresponding strength of the connection, and on its numerical
modeling using FEM. This paper is focused only on the cyclic
loading (fatigue) tests results of “splice-plate” connections and their
evaluation, which have already been finished. Simultaneously with
the fatigue tests, the static loading tests have been realized too, but
these ones, as well as FEM numerical modeling, are not the subject of
this paper.
Abstract: Although many studies on the assembly technology of
the bridge construction have dealt mostly with on the pier, girder or the
deck of the bridge, studies on the prefabricated barrier have rarely been
performed. For understanding structural characteristics and
application of the concrete barrier in the modular bridge, which is an
assembly of structure members, static loading test was performed.
Structural performances as a road barrier of the three methods,
conventional cast-in-place(ST), vertical bolt connection(BVC) and
horizontal bolt connection(BHC) were evaluated and compared
through the analyses of load-displacement curves, strain curves of the
steel, concrete strain curves and the visual appearances of crack
patterns. The vertical bolt connection(BVC) method demonstrated
comparable performance as an alternative to conventional
cast-in-place(ST) while providing all the advantages of prefabricated
technology. Necessities for the future improvement in nuts
enforcement as well as legal standard and regulation are also
addressed.