Abstract: In a deregulated power system structure, power producers and customers share a common transmission network for wheeling power from the point of generation to the point of consumption. All parties in this open access environment may try to purchase the energy from the cheaper source for greater profit margins, which may lead to overloading and congestion of certain corridors of the transmission network. This may result in violation of line flow, voltage and stability limits and thereby undermine the system security. Utilities therefore need to determine adequately their available transfer capability (ATC) to ensure that system reliability is maintained while serving a wide range of bilateral and multilateral transactions. This paper presents power transfer distribution factor based on AC load flow for the determination and enhancement of ATC. The study has been carried out for IEEE 24 bus Reliability Test System.
Abstract: This work presents an approach for AC load flow based centralized model for congestion management in the forward markets. In this model, transaction maximizes its profit under the limits of transmission line capacities allocated by Independent System Operator (ISO). The voltage and reactive power impact of the system are also incorporated in this model. Genetic algorithm is used to solve centralized congestion management problem for multilateral transactions. Results obtained for centralized model using genetic algorithm is compared with Sequential Quadratic Programming (SQP) technique. The statistical performances of various algorithms such as best, worst, mean and standard deviations of social welfare are given. Simulation results clearly demonstrate the better performance of genetic algorithm over SQP.
Abstract: Renewable Energy based microgrids are being considered to provide electricity for the expanding energy demand in the grid distribution network and grid isolated areas. The technical challenges associated with the operation and controls are immense. Electricity generation by Renewable Energy Sources is of stochastic nature such that there is a demand for regulation of voltage output in order to satisfy the standard loads’ requirements. In a renewable energy based microgrid, the energy sources give stochastically variable magnitude AC or DC voltages. AC voltage regulation of micro and mini sources pose practical challenges as well as unbearable costs. It is therefore practically and economically viable to convert the voltage outputs from stochastic AC and DC voltage sources to constant DC voltage to satisfy various DC loads including inverters which ultimately feed AC loads. This paper presents results obtained from SEPIC converter based DC bus voltage regulator as a case study for renewable energy microgrid application. Real-Time Simulation results show that upon appropriate choice of controller parameters for control of the SEPIC converter, the output DC bus voltage can be kept constant regardless of wide range of voltage variations of the source. This feature is particularly important in the situation that multiple renewable sources are to be integrated to supply a microgrid under main grid integration or isolated modes of operation.
Abstract: In this study, we discussed the effects on the thermal
comfort of super high-rise residences that how effected by the high
thermal capacity structural components. We considered different
building orientations, structures, and insulation methods. We used the
dynamic simulation software THERB (simulation of the thermal
environment of residential buildings). It can estimate the temperature,
humidity, sensible temperature, and heating/cooling load for multiple
buildings. In the past studies, we examined the impact of
air-conditioning loads (hereinafter referred to as AC loads) on the
interior structural parts and the AC-usage patterns of super-high-rise
residences.
Super-high-rise residences have more structural components such
as pillars and beams than do ordinary apartment buildings. The
skeleton is generally made of concrete and steel, which have high
thermal-storage capacities. The thermal-storage capacity of
super-high-rise residences is considered to have a larger impact on the
AC load and thermal comfort than that of ordinary residences.
We show that the AC load of super-high-rise units would be
reduced by installing insulation on the surfaces of interior walls that
are not usually insulated in Japan.
Abstract: This paper discusses the approach of real-time
controlling of the energy management system using the data
acquisition tool of LabVIEW. The main idea of this inspiration was
to interface the Station (PC) with the system and publish the data on
internet using LabVIEW. In this venture, controlling and switching of
3 phase AC loads are effectively and efficiently done. The phases are
also sensed through devices. In case of any failure the attached
generator starts functioning automatically. The computer sends
command to the system and system respond to the request. The
modern feature is to access and control the system world-wide using
world wide web (internet). This controlling can be done at any time
from anywhere to effectively use the energy especially in developing
countries where energy management is a big problem. In this system
totally integrated devices are used to operate via remote location.