Abstract: In this paper we show that adjusting ART in accordance with static network scenario can substantially improve the performance of AODV by reducing control overheads. We explain the relationship of control overheads with network size and request patterns of the users. Through simulation we show that making ART proportionate to network static time reduces the amount of control overheads independent of network size and user request patterns.
Abstract: The incorporation of renewable energy sources for the sustainable electricity production is undertaking a more prominent role in electric power systems. Thus, it will be an indispensable incident that the characteristics of future power networks, their prospective stability for instance, get influenced by the imposed features of sustainable energy sources. One of the distinctive attributes of the sustainable energy sources is exhibiting the stochastic behavior. This paper investigates the impacts of this stochastic behavior on the small disturbance rotor angle stability in the upcoming electric power networks. Considering the various types of renewable energy sources and the vast variety of system configurations, the sensitivity analysis can be an efficient breakthrough towards generalizing the effects of new energy sources on the concept of stability. In this paper, the definition of small disturbance angle stability for future power systems and the iterative-stochastic way of its analysis are presented. Also, the effects of system parameters on this type of stability are described by performing a sensitivity analysis for an electric power test system.
Abstract: Currently, there are many local area industrial networks
that can give guaranteed bandwidth to synchronous traffic, particularly
providing CBR channels (Constant Bit Rate), which allow
improved bandwidth management. Some of such networks operate
over Ethernet, delivering channels with enough capacity, specially
with compressors, to integrate multimedia traffic in industrial monitoring
and image processing applications with many sources. In
these industrial environments where a low latency is an essential
requirement, JPEG is an adequate compressing technique but it
generates VBR traffic (Variable Bit Rate). Transmitting VBR traffic
in CBR channels is inefficient and current solutions to this problem
significantly increase the latency or further degrade the quality. In
this paper an R(q) model is used which allows on-line calculation of
the JPEG quantification factor. We obtained increased quality, a lower
requirement for the CBR channel with reduced number of discarded
frames along with better use of the channel bandwidth.
Abstract: Nowadays in applications of renewable energy sources
it is important to develop powerful and energy-saving photovoltaic
converters and to keep the prescriptions of the standards. In grid
connected PV converters the obvious solution to increase the
efficiency is to reduce the switching losses. Our new developed
control method reduces the switching losses and keeps the limitations
of the harmonic distortion standards. The base idea of the method is
the utilization of 3-state control causing discontinuous current mode
at low input power. In the following sections the control theory, the
realizations and the simulation results are presented.
Abstract: Electric impedance imaging is a method of
reconstructing spatial distribution of electrical conductivity inside a
subject. In this paper, a new method of electrical impedance imaging
using eddy current is proposed. The eddy current distribution in the
body depends on the conductivity distribution and the magnetic field
pattern. By changing the position of magnetic core, a set of voltage
differences is measured with a pair of electrodes. This set of voltage
differences is used in image reconstruction of conductivity
distribution. The least square error minimization method is used as a
reconstruction algorithm. The back projection algorithm is used to
get two dimensional images. Based on this principle, a measurement
system is developed and some model experiments were performed
with a saline filled phantom. The shape of each model in the
reconstructed image is similar to the corresponding model,
respectively. From the results of these experiments, it is confirmed
that the proposed method is applicable in the realization of electrical
imaging.
Abstract: The ability to detect and classify the type of fault
plays a great role in the protection of power system. This procedure
is required to be precise with no time consumption. In this paper
detection of fault type has been implemented using wavelet analysis
together with wavelet entropy principle. The simulation of power
system is carried out using PSCAD/EMTDC. Different types of
faults were studied obtaining various current waveforms. These
current waveforms were decomposed using wavelet analysis into
different approximation and details. The wavelet entropy of such
decompositions is analyzed reaching a successful methodology for
fault classification. The suggested approach is tested using different
fault types and proven successful identification for the type of fault.
Abstract: A lightpipe is an about 99 percent specular reflective
mirror pipe or duct that is used for the transmission of the daylight
from the outside into a building. The lightpipes are usually used in
the daylighting buildings, in the residential, industrial and
commercial sectors. This paper is about the performances of a
lightpipe installed in a laboratory (3 m x 2.6 m x 3 m) without
windows. The aim is to analyse the luminous intensity distribution
for several sky/sun conditions. The lightpipe was monitored during
the year 2006. The lightpipe is 1 m long and the diameter of the top
collector and of the internal diffuser device is 0.25 m. In the
laboratory there are seven illuminance sensors: one external is
located on the roof of the laboratory and six internal sensors are
connected to a data acquisition system. The internal sensors are
positioned under the internal diffusive device at an height of 0.85 m
from the floor to simulate a working plane. The numerical data are
obtained through a simulation software. This paper shows the
comparison between the experimental and numerical results
concerning the behavior of the lightpipe.
Abstract: The tracing methods determine the contribution the
power system sources have in their supplying. The methods can be used
to assess the transmission prices, but also to recover the transmission
fixed cost. In this paper is presented the influence of the modification of
commons structure has on the specific price of transfer. The operator
must make use of a few basic principles about allocation. Most
tracing methods are based on the proportional sharing principle. In this
paper Kirschen method is used. In order to illustrate this method, the 25-
bus test system is used, elaborated within the Electrical Power
Engineering Department, from Timisoara, Romania.
Abstract: A considerable amount of energy is consumed during
transmission and reception of messages in a wireless mesh network
(WMN). Reducing per-node transmission power would greatly
increase the network lifetime via power conservation in addition to
increasing the network capacity via better spatial bandwidth reuse. In
this work, the problem of topology control in a hybrid WMN of
heterogeneous wireless devices with varying maximum transmission
ranges is considered. A localized distributed topology control
algorithm is presented which calculates the optimal transmission
power so that (1) network connectivity is maintained (2) node
transmission power is reduced to cover only the nearest neighbours
(3) networks lifetime is extended. Simulations and analysis of results
are carried out in the NS-2 environment to demonstrate the
correctness and effectiveness of the proposed algorithm.
Abstract: The development of the power electronics has allowed
increasing the precision and reliability of the electrical devices, thanks
to the adjustable inverters, as the Pulse Wide Modulation (PWM)
applied to the three level inverters, which is the object of this study.
The authors treat the relation between the law order adopted for a
given system and the oscillations of the electrical and mechanical
parameters of which the tolerance depends on the process with which
they are integrated (paper factory, lifting of the heavy loads,
etc.).Thus, the best choice of the regulation indexes allows us to
achieve stability and safety training without investment (management
of existing equipment). The optimal behavior of any electric device
can be achieved by the minimization of the stored electrical and
mechanical energy.
Abstract: Information and communication service providers
(ICSP) that are significant in size and provide Internet-based services
take administrative, technical, and physical protection measures via
the information security check service (ISCS). These protection
measures are the minimum action necessary to secure the stability and
continuity of the information and communication services (ICS) that
they provide. Thus, information assets are essential to providing ICS,
and deciding the relative importance of target assets for protection is a
critical procedure. The risk analysis model designed to decide the
relative importance of information assets, which is described in this
study, evaluates information assets from many angles, in order to
choose which ones should be given priority when it comes to
protection. Many-sided risk analysis (MSRS) grades the importance of
information assets, based on evaluation of major security check items,
evaluation of the dependency on the information and communication
facility (ICF) and influence on potential incidents, and evaluation of
major items according to their service classification, in order to
identify the ISCS target. MSRS could be an efficient risk analysis
model to help ICSPs to identify their core information assets and take
information protection measures first, so that stability of the ICS can
be ensured.
Abstract: The Ad Hoc on demand distance vector (AODV) routing protocol is designed for mobile ad hoc networks (MANETs). AODV offers quick adaptation to dynamic link conditions; it is characterized by low memory overhead and low network utilization. The security issues related to the protocol remain challenging for the wireless network designers. Numerous schemes have been proposed for establishing secure communication between end users, these schemes identify that the secure operation of AODV is a bi tier task (routing and secure exchange of information at separate levels). Our endeavor in this paper would focus on achieving the routing and secure data exchange in a single step. This will facilitate the user nodes to perform routing, mutual authentications, generation and secure exchange of session key in one step thus ensuring confidentiality, integrity and authentication of data exchange in a more suitable way.
Abstract: Delivering streaming video over wireless is an
important component of many interactive multimedia applications
running on personal wireless handset devices. Such personal devices
have to be inexpensive, compact, and lightweight. But wireless
channels have a high channel bit error rate and limited bandwidth.
Delay variation of packets due to network congestion and the high bit
error rate greatly degrades the quality of video at the handheld
device. Therefore, mobile access to multimedia contents requires
video transcoding functionality at the edge of the mobile network for
interworking with heterogeneous networks and services. Therefore,
to guarantee quality of service (QoS) delivered to the mobile user, a
robust and efficient transcoding scheme should be deployed in
mobile multimedia transporting network. Hence, this paper
examines the challenges and limitations that the video transcoding
schemes in mobile multimedia transporting network face. Then
handheld resources, network conditions and content based mobile
and wireless video transcoding is proposed to provide high QoS
applications. Exceptional performance is demonstrated in the
experiment results. These experiments were designed to verify and
prove the robustness of the proposed approach. Extensive
experiments have been conducted, and the results of various video
clips with different bit rate and frame rate have been provided.
Abstract: Firstly, research and development on RFID focuses on
manufacturing and retail sectors, because it can improve supply chain
efficiency. But, now a variety of field is considered the next research
area for Radio Frequency Identification (RFID). Although RFID is
infancy, RFID technology has great potential in power industry to
significantly reduce cost, and improve quality of power supply. To
complement the limitation of RFID, we adopt the WSN (Wireless
Sensor Network) technology. However, relevant experience is limited,
the challenge will be to derive requirement from business practice and
to determine whether it is possible or not. To explore this issue, we
conduct a case study on implementing power facility management
system using RFID/WSN in Korea Electric Power Corporation
(KEPCO). In this paper we describe requirement from power industry.
And we introduce design and implementation of the test bed.
Abstract: Network management techniques have long been of
interest to the networking research community. The queue size plays
a critical role for the network performance. The adequate size of the
queue maintains Quality of Service (QoS) requirements within
limited network capacity for as many users as possible. The
appropriate estimation of the queuing model parameters is crucial for
both initial size estimation and during the process of resource
allocation. The accurate resource allocation model for the
management system increases the network utilization. The present
paper demonstrates the results of empirical observation of memory
allocation for packet-based services.
Abstract: Nowadays there are several grid connected converter
in the grid system. These grid connected converters are generally the
converters of renewable energy sources, industrial four quadrant
drives and other converters with DC link. These converters are
connected to the grid through a three phase bridge. The standards
prescribe the maximal harmonic emission which could be easily
limited with high switching frequency. The increased switching
losses can be reduced to the half with the utilization of the wellknown
Flat-top modulation. The suggested control method is the
expansion of the Flat-top modulation with which the losses could be
also reduced to the half compared to the Flat-top modulation.
Comparing to traditional control these requirements can be
simultaneously satisfied much better with the DLF (DC Link
Floating) method.
Abstract: The performance of adaptive beamforming degrades
substantially in the presence of steering vector mismatches. This
degradation is especially severe in the near-field, for the
3-dimensional source location is more difficult to estimate than the
2-dimensional direction of arrival in far-field cases. As a solution, a
novel approach of near-field robust adaptive beamforming (RABF) is
proposed in this paper. It is a natural extension of the traditional
far-field RABF and belongs to the class of diagonal loading
approaches, with the loading level determined based on worst-case
performance optimization. However, different from the methods
solving the optimal loading by iteration, it suggests here a simple
closed-form solution after some approximations, and consequently,
the optimal weight vector can be expressed in a closed form. Besides
simplicity and low computational cost, the proposed approach reveals
how different factors affect the optimal loading as well as the weight
vector. Its excellent performance in the near-field is confirmed via a
number of numerical examples.
Abstract: In this paper the problem of estimating the time delay
between two spatially separated noisy sinusoidal signals by system
identification modeling is addressed. The system is assumed to be
perturbed by both input and output additive white Gaussian noise. The
presence of input noise introduces bias in the time delay estimates.
Normally the solution requires a priori knowledge of the input-output
noise variance ratio. We utilize the cascade of a self-tuned filter with
the time delay estimator, thus making the delay estimates robust to
input noise. Simulation results are presented to confirm the superiority
of the proposed approach at low input signal-to-noise ratios.
Abstract: At present, the tendency to implement the conditionbased
maintenance (CBM), which allows the optimization of the
expenses for equipment monitoring, is more and more evident; also,
the transformer substations with remote monitoring are increasingly
used. This paper reviews all the advantages of the on-line monitoring
and presents an equipment for on-line monitoring of bushings, which
is the own contribution of specialists who are the authors of this
paper. The paper presents a study of the temperature field, using the
finite element method. For carrying out this study, the 3D modelling
of the above mentioned bushing was performed. The analysis study is
done taking into account the extreme thermal stresses, focusing at the
level of the first cooling wing section of the ceramic insulator. This
fact enables to justify the tanδ variation in time, depending on the
transformer loading and the environmental conditions. With a view
to reducing the variation of dielectric losses in bushing insulation, the
use of ferrofuids instead of mineral oils is proposed.
Abstract: Off-grid Photovoltaic (PV) systems are empowering
technology in underdeveloped countries like Ethiopia where many
people live far away from the modern world. Where there is
relatively low energy consumption, providing energy from grid
systems is not commercially cost-effective. As a result, significant
people groups worldwide stay without access to electricity. One
remote village in northern Ethiopia was selected by the United
Nations for a pilot project to improve its living conditions. As part of
this comprehensive project, an intelligent charge controller circuit for
Off-grid PV systems was designed for the clinic in that village. In
this paper, design aspects of an intelligent charge controller unit and
its load driver circuits are discussed for an efficient utilization of PVbased
supply systems.