Abstract: Climate considerations are essential dimensions in the assessment of thermal comfort and indoor environments inside Egyptian housing. The primary aim of this paper is to analyze the indoor environment of new housing in the new city of Assiut in the Southern Upper Egypt zone, in order to evaluate its thermal environment and determine the acceptable indoor operative temperatures. The psychrometric charts for ASHRAE Standard 55 and ACS used in this study would facilitate an overall representation of the climate in one of the hottest months in the summer season. This study helps to understand and deal with this problem and work on a passive cooling ventilation strategy in these contexts in future studies. The results that demonstrated the indoor temperature is too high, ranges between 31°C to 40°C in different natural ventilation strategies. This causes the indoor environment to be far from the optimum comfort operative temperature of ACS except when using air conditioners. Finally, this study is considered a base for developing a new system using natural ventilation with passive cooling strategies.
Abstract: Stiffness of Hot Mix Asphalt (HMA) in flexible pavement is largely dependent of temperature, mode of testing and age of pavement. Accurate measurement of HMA stiffness is thus quite challenging. This study determines HMA stiffness based on Finite Element Model (FEM) and validates the results using field data. As a first step, stiffnesses of different layers of a pavement section on Interstate 40 (I-40) in New Mexico were determined by Falling Weight Deflectometer (FWD) test. Pavement temperature was not measured at that time due to lack of temperature probe. Secondly, a FE model is developed in ABAQUS. Stiffness of the base, subbase and subgrade were taken from the FWD test output obtained from the first step. As HMA stiffness largely varies with temperature it was assigned trial and error approach. Thirdly, horizontal strain and vertical stress at the bottom of the HMA and temperature at different depths of the pavement were measured with installed sensors on the whole day on December 25th, 2012. Fourthly, outputs of FEM were correlated with measured stress-strain responses. After a number of trials a relationship was developed between the trial stiffness of HMA and measured mid-depth HMA temperature. At last, the obtained relationship between stiffness and temperature is verified by further FWD test when pavement temperature was recorded. A promising agreement between them is observed. Therefore, conclusion can be drawn that linear elastic FEM can accurately predict the stiffness and the structural response of flexible pavement.
Abstract: Recently in the field of bridges that are newly built or
repaired, fast construction is required more than ever. For these
reasons, precast prefabricated bridge that enables rapid construction is
actively discussed and studied today. In South Korea, it is called
modular bridge. Cross beam is an integral component of modular
bridge. It functions for load distribution, reduction of bending
moment, resistance of horizontal strength on lateral upper structure. In
this study, the structural characteristics of domestic and foreign cross
beam types were compared. Based on this, alternative cross beam
connection types suitable for modular bridge were selected. And
bulb-T girder specimens were fabricated with each type of connection.
The behavior of each specimen was analyzed under static loading, and
cross beam connection type which is expected to be best suited to
modular bridge proposed.
Abstract: The work presents a development of EN338 strength classes for Strombosia pustulata, Pterygotama crocarpa, Nauclea diderrichii and Entandrophragma cyclindricum Nigerian timber species. The specimens for experimental measurements were obtained from the timber-shed at the famous Panteka market in Kaduna in the northern part of Nigeria. Laboratory experiments were conducted to determine the physical and mechanical properties of the selected timber species in accordance with EN 13183-1 and ASTM D193. The mechanical properties were determined using three point bending test. The generated properties were used to obtain the characteristic values of the material properties in accordance with EN384. The selected timber species were then classified according to EN 338. Strombosia pustulata, Pterygotama crocarpa, Nauclea diderrichii and Entandrophragma cyclindricum were assigned to strength classes D40, C14, D40 and D24 respectively. Other properties such as tensile and compressive strengths parallel and perpendicular to grains, shear strength as well as shear modulus were obtained in accordance with EN 338.
Abstract: A self-compacting concrete (SCC) is the one that can
be placed in the form and can go through obstructions by its own
weight and without the need of vibration. Since its first development
in Japan in 1988, SCC has gained wider acceptance in Japan, Europe
and USA due to its inherent distinct advantages. Although there are
visible signs of its gradual acceptance in the North Africa through its
limited use in construction, Libya has yet to explore the feasibility
and applicability of SCC in new construction. The contributing
factors to this reluctance appear to be lack of any supportive
evidence of its suitability with local aggregates and the harsh
environmental conditions. The primary aim of this study is to explore
the feasibility of using SCC made with local aggregates of Eastern
Province of Libya by examining its basic properties characteristics.
This research consists of: (i) Development of a suitable mix for SCC
such as the effect of water to cement ratio, limestone and silica fume
that would satisfy the requirements of the plastic state; (ii) Casting of
concrete samples and testing them for compressive strength and unit
weight. Local aggregates, cement, admixtures and industrial waste
materials were used in this research.
The significance of this research lies in its attempt to provide
some performance data of SCC made in the Eastern Province of
Libya so as to draw attention to the possible use of SCC.
Abstract: Indoor air distribution has great impact on people-s thermal sensation. Therefore, how to remove the indoor excess heat becomes an important issue to create a thermally comfortable indoor environment. To expel the extra indoor heat effectively, this paper used a dynamic CFD approach to study the effect of an air-supply guide vane swinging periodically on the indoor air distribution within a model room. The numerical results revealed that the indoor heat transfer performance caused by the swing guide vane had close relation with the number of vortices developing under the inlet cold jet. At larger swing amplitude, two smaller vortices continued to shed outward under the cold jet and remove the indoor heat load more effectively. As a result, it can be found that the average Nusselt number on the floor increased with the increase of the swing amplitude of the guide vane.
Abstract: This study is to evaluate the behavior of integral and
segmental specimens through static and cyclic tests. Integral
specimens were made with the same size to be compared with
segmental specimens that were made by connected precast members.
To evaluate its bending performance and serviceability, 1 integral and
3 segmental specimens were tested under static load. And 1 integral
and 2 segmental specimens were tested under cyclic load, respectively.
Different load ranges were considered in the cyclic tests to evaluate the
safety and serviceability. The test results showed that under static
loading, segmental specimens had about 94% of the integral
specimen's maximum moment, averagely. Under cyclic loading, the
segmental specimens showed that had enough safety in the range of
higher than service load and enough serviceability. In conclusion, the
maximum crack width (0.16mm) satisfied the allowable crack width
(0.30mm) in the range of service load.
Abstract: There is a great deal of interest in constructing Double Skin Facade (DSF) structures which are considered as modern movement in field of Energy Conservation, renewable energies, and Architecture design. This trend provides many conclusive alternatives which are frequently associated with sustainable building. In this paper a building with Double Skin Facade is considered in the semiarid climate of Tehran, Iran, in order to consider the DSF-s performance during hot seasons. Mathematical formulations calculate solar heat gain by the external skin. Moreover, Computational Fluid Dynamics (CFD) simulations were performed on the case study building to enhance effectiveness of the facade. The conclusion divulged difference of gained energy by the cavity and room with and without blind and louvers. Some solutions were introduced to surge the performance of natural ventilation by plunging the cooling loads in summer.