Abstract: The unanticipated destruct of more of the steel moment frames in Northridge earthquake, altered class of regard to the beamto- column connections in moment frames. Panel zone is one the significant part of joints which, it-s stiffness and rigidity has an important effect on the behavior and ductility of the frame. Specifically that behavior of panel zone has a very significant effect on the special moment frames. In this paper , meanwhile the relations for modeling of panel zone in frames are expressed , special moment frames with different spans and stories were studied in the way of performance-based design. The frames designed in according with Iranian steel building code. The effect of panel zone is also considered and in the case of non-existence of performance level, by changing in intimacies and parameter of panel zone, performance level is considered.
Abstract: Interior brick-infill partitions are usually considered as
non-structural components, and only their weight is accounted for in
practical structural design. In this study, the brick-infill panels are
simulated by compression struts to clarify their effect on the
progressive collapse potential of an earthquake-resistant RC building.
Three-dimensional finite element models are constructed for the RC
building subjected to sudden column loss. Linear static analyses are
conducted to investigate the variation of demand-to-capacity ratio
(DCR) of beam-end moment and the axial force variation of the beams
adjacent to the removed column. Study results indicate that the
brick-infill effect depends on their location with respect to the
removed column. As they are filled in a structural bay with a shorter
span adjacent to the column-removed line, more significant reduction
of DCR may be achieved. However, under certain conditions, the
brick infill may increase the axial tension of the two-span beam
bridging the removed column.
Abstract: The knee bracing steel frame (KBF) is a new kind of energy dissipating frame, which combines excellent ductility and lateral stiffness. In this framing system, a special form of diagonal brace connected to a knee element instead of beam-column joint, is investigated. Recently, a similar system was proposed and named as chevron knee bracing system (CKB) which in comparison with the former system has a better energy absorption characteristic and at the same time retains the elastic nature of the structures. Knee bracing can provide a stiffer bracing system but reduces the ductility of the steel frame. Chevron knee bracing can be employed to provide the desired ductility level for a design. In this article, relation between seismic performance and structural parameters of the two above mentioned systems are investigated and compared. Frames with similar dimensions but various heights in both systems are designed according to Iranian code of practice for seismic resistant design of building, and then based on a non-linear push over static analysis; the seismic parameters such as behavior factor and performance levels are compared.
Abstract: Because of architectural condition and structure application, sometimes mass source and stiffness source are not coincidence, and the structure is irregular. The structure is also might be asymmetric as an asymmetric bracing in plan which leads to unbalance distribution of stiffness or because of unbalance distribution of the mass. Both condition lead to eccentricity and torsion in the structure. The deficiency of ordinary code to evaluate the performance of steel structures against earthquake has been caused designing based on performance level or capacity spectrum be used. By using the mentioned methods it is possible to design a structure that its behavior against different earthquakes be predictive. In this article 5- story buildings with different percentage of asymmetric which is because of stiffness changes and kind of bracing (x and chevron bracing) have been designed. The static and dynamic nonlinear analysis under three acceleration recording has been done. Finally performance level of the structure has been evaluated.
Abstract: For Seismic design, it is important to estimate,
maximum lateral displacement (inelastic displacement) of the
structures due to sever earthquakes for several reasons. Seismic
design provisions estimate the maximum roof and storey drifts
occurring in major earthquakes by amplifying the drifts of the
structures obtained by elastic analysis subjected to seismic design
load, with a coefficient named “displacement amplification factor"
which is greater than one. Here, this coefficient depends on various
parameters, such as ductility and overstrength factors. The present
research aims to evaluate the value of the displacement amplification
factor in seismic design codes and then tries to propose a value to
estimate the maximum lateral structural displacement from sever
earthquakes, without using non-linear analysis. In seismic codes,
since the displacement amplification is related to “force reduction
factor" hence; this aspect has been accepted in the current study.
Meanwhile, two methodologies are applied to evaluate the value of
displacement amplification factor and its relation with the force
reduction factor. In the first methodology, which is applied for all
structures, the ratio of displacement amplification and force reduction
factors is determined directly. Whereas, in the second methodology
that is applicable just for R/C moment resisting frame, the ratio is
obtained by calculating both factors, separately. The acquired results
of these methodologies are alike and estimate the ratio of two factors
from 1 to 1.2. The results indicate that the ratio of the displacement
amplification factor and the force reduction factor differs to those
proposed by seismic provisions such as NEHRP, IBC and Iranian
seismic code (standard no. 2800).
Abstract: This paper describes the development of a numerical finite element algorithm used for the analysis of reinforced concrete structure equipped with shakes energy absorbing device subjected to earthquake excitation. For this purpose a finite element program code for analysis of reinforced concrete frame buildings is developed. The performance of developed program code is evaluated by analyzing of a reinforced concrete frame buildings model. The results are show that using damper device as seismic energy dissipation system effectively can reduce the structural response of framed structure during earthquake occurrence.
Abstract: In this study, shaking table tests are performed to investigate the behavior of excess pore water pressure in different soft soil-foundations of soil-structure interaction (SSI) system. The variation of the behaviors under cycled minor shock is observed. Moreover, The generation and variation mechanism of excess pore water pressure under earthquake excitation in different soft soilfoundations are analyzed and discussed.
Abstract: As a simple to method estimate the plant heating energy
capacity of an apartment complex, a new load calculation method has
been proposed. The method which can be called as unit building
method, predicts the heating load of the entire complex instead of
summing up that of each apartment belonging to complex.
Comparison of the unit heating load for various floor sizes between the
present method and conventional approach shows a close agreement
with dynamic load calculation code. Some additional calculations are
performed to demonstrate it-s application examples.
Abstract: Stick models are widely used in studying the
behaviour of straight as well as skew bridges and viaducts subjected
to earthquakes while carrying out preliminary studies. The
application of such models to highly curved bridges continues to
pose challenging problems. A viaduct proposed in the foothills of the
Himalayas in Northern India is chosen for the study. It is having 8
simply supported spans @ 30 m c/c. It is doubly curved in horizontal
plane with 20 m radius. It is inclined in vertical plane as well. The
superstructure consists of a box section. Three models have been
used: a conventional stick model, an improved stick model and a 3D
finite element model. The improved stick model is employed by
making use of body constraints in order to study its capabilities. The
first 8 frequencies are about 9.71% away in the latter two models.
Later the difference increases to 80% in 50th mode. The viaduct was
subjected to all three components of the El Centro earthquake of May
1940. The numerical integration was carried out using the Hilber-
Hughes-Taylor method as implemented in SAP2000. Axial forces
and moments in the bridge piers as well as lateral displacements at
the bearing levels are compared for the three models. The maximum
difference in the axial forces and bending moments and
displacements vary by 25% between the improved and finite element
model. Whereas, the maximum difference in the axial forces,
moments, and displacements in various sections vary by 35%
between the improved stick model and equivalent straight stick
model. The difference for torsional moment was as high as 75%. It is
concluded that the stick model with body constraints to model the
bearings and expansion joints is not desirable in very sharp S curved
viaducts even for preliminary analysis. This model can be used only
to determine first 10 frequency and mode shapes but not for member
forces. A 3D finite element analysis must be carried out for
meaningful results.
Abstract: In the territories where high-intensity
earthquakes are frequent is paid attention to the solving of the
seismic problems. In the paper are described two
computational model variants based on finite element method
of the construction with different subsoil simulation (rigid or
elastic subsoil) is used. For simulation and calculations
program system based on method final elements ANSYS was
used. Seismic responses calculations of residential building
structure were effected on loading characterized by
accelerogram for comparing with the responses spectra
method.
Abstract: Because of architectural condition and structure application, sometimes mass source and stiffness source are not coincidence, and the structure is irregular. The structure is also might be asymmetric as an asymmetric bracing in plan which leads to unbalance distribution of stiffness or because of unbalance distribution of the mass. Both condition lead to eccentricity and torsion in the structure. The deficiency of ordinary code to evaluate the performance of steel structures against earthquake has been caused designing based on performance level or capacity spectrum be used. By using the mentioned methods it is possible to design a structure that its behavior against different earthquakes be predictive. In this article 5- story buildings with different percentage of asymmetric which is because of stiffness changes have been designed. The static and dynamic nonlinear analysis under three acceleration recording has been done. Finally performance level of the structure has been evaluated.
Abstract: Analytical seismic response of multi-story building
supported on base isolation system is investigated under real
earthquake motion. The superstructure is idealized as a shear type
flexible building with lateral degree-of-freedom at each floor. The
force-deformation behaviour of the isolation system is modelled by
the bi-linear behaviour which can be effectively used to model all
isolation systems in practice. The governing equations of motion of
the isolated structural system are derived. The response of the system
is obtained numerically by step-by-method under three real recorded
earthquake motions and pulse motions associated in the near-fault
earthquake motion. The variation of the top floor acceleration, interstory
drift, base shear and bearing displacement of the isolated
building is studied under different initial stiffness of the bi-linear
isolation system. It was observed that the high initial stiffness of the
isolation system excites higher modes in base-isolated structure and
generate floor accelerations and story drift. Such behaviour of the
base-isolated building especially supported on sliding type of
isolation systems can be detrimental to sensitive equipment installed
in the building. On the other hand, the bearing displacement and base
shear found to reduce marginally with the increase of the initial
stiffness of the initial stiffness of the isolation system. Further, the
above behaviour of the base-isolated building was observed for
different parameters of the bearing (i.e. post-yield stiffness and
characteristic strength) and earthquake motions (i.e. real time history
as well as pulse type motion).
Abstract: In order to upgrade the seismic resistibility of structures and enhance the functionality of an isolator, a new base isolator called the multiple trench friction pendulum system (MTFPS) is proposed in this study. The proposed MTFPS isolator is composed of a trench concave surface and several intermediate sliding plates in two orthogonal directions. Mathematical formulations have been derived to examine the characteristics of the proposed MTFPS isolator possessing multiple intermediate sliding plates. By means of mathematical formulations, it can be inferred that the natural period and damping effect of the MTFPS isolator with several intermediate sliding plates can be altered continually and controllably during earthquakes. Furthermore, results obtained from shaking table tests demonstrate that the proposed isolator provides good protection to structures for prevention of damage from strong earthquakes.
Abstract: The leisure boatbuilding industry has tight profit margins that demand that boats are created to a high quality but with low cost. This requirement means reduced design times combined with increased use of design for production can lead to large benefits. The evolutionary nature of the boatbuilding industry can lead to a large usage of previous vessels in new designs. With the increase in automated tools for concurrent engineering within structural design it is important that these tools can reuse this information while subsequently feeding this to designers. The ability to accurately gather this materials and parts data is also a key component to these tools. This paper therefore aims to develop an architecture made up of neural networks and databases to feed information effectively to the designers based on previous design experience.
Abstract: Many footbridges have natural frequencies that
coincide with the dominant frequencies of the pedestrian-induced
load and therefore they have a potential to suffer excessive vibrations
under dynamic loads induced by pedestrians. Some of the design
standards introduce load models for pedestrian loads applicable for
simple structures. Load modeling for more complex structures, on the
other hand, is most often left to the designer. The main focus of this
paper is on the human induced forces transmitted to a footbridge and
on the ways these loads can be modeled to be used in the dynamic
design of footbridges. Also design criteria and load models proposed
by widely used standards were introduced and a comparison was
made. The dynamic analysis of the suspension bridge in Kolin in the
Czech Republic was performed on detailed FEM model using the
ANSYS program system. An attempt to model the load imposed by a
single person and a crowd of pedestrians resulted in displacements
and accelerations that are compared with serviceability criteria.
Abstract: In the paper, the results of sensitivity analysis of the influence of initial imperfections on the web stress state of a thinwalled girder are presented. The results of the study corroborate a very good and effective agreement of experiments with theory. Most input random quantities were found experimentally. The change of sensitivity coefficients in dependence on working load value is analysed. The stress was analysed by means of a geometrically and materially non-linear solution by applying the program ANSYS. This research study offers important background for theoretical studies of stability problems, post-critical effects and limit states of thin-walled steel structures.