QCM-D Study on Relationship of PEG Coated Stainless Steel Surfaces to Protein Resistance

Nonspecific protein adsorption generally occurs on any solid surfaces and usually has adverse consequences. Adsorption of proteins onto a solid surface is believed to be the initial and controlling step in biofouling. Surfaces modified with end-tethered poly(ethylene glycol) (PEG) have been shown to be protein-resistant to some degree. In this study, the adsorption of β-casein and lysozyme was performed on 6 different types of surfaces where PEG was tethered onto stainless steel by polyethylene imine (PEI) through either OH or NHS end groups. Protein adsorption was also performed on the bare stainless steel surface as a control. The adsorption was conducted at 23 °C and pH 7.2. In situ QCM-D was used to determine PEG adsorption kinetics, plateau PEG chain densities, protein adsorption kinetics and plateau protein adsorbed quantities. PEG grafting density was the highest for a NHS coupled chain, around 0.5 chains / nm2. Interestingly, lysozyme which has smaller size than β-casein, appeared to adsorb much less mass than that of β- casein. Overall, the surface with high PEG grafting density exhibited a good protein rejection.




References:
[1] P. Kingshott, W. Jiang, G. B. Nikolaj and G. Lone, G, "Covalent
attachment of Poly(ethylene glycol) to surfaces, critical for reducing
bacterial adhesion", Langmuir. vol. 19, pp. 6912-6921, 2003
[2] L.D.Unsworth, H.Sheardown and J.L.Brash, "Protein resistance of
surfaces prepared by sorption of end-thiolated poly(ethylene glycol) to
gold:Effect of surface chain density", Langmuir. vol. 21. pp.1036-1041,
2005
[3] T.Satomi, Y.Nagasaki, H.Kobayashi, T.Tateishi, K.Kataoka and
H.Otsuka, "Physicochemical characterization of densely packed poly
(ethylene glycol) layer for minimizing nonspecific protein adsorption",
Journal of Nanoscience and Nanotechnology, vol. 7, pp. 2394-2399,
2007
[4] J. Wei, D.B. Ravn, L. Gram and P. Kingshott, "Stainless Steel Modified
with PEG can Prevent Protein Adsorption but not Bacterial Adhesion",
Colloids and Surfaces B: Biointerfaces, vol. 32, pp. 275-291.2005
[5] J.G. Archambault and J.L. Brash, "Protein Repellent Polyurethane-Urea
Surfaces by Chemical Grafting of Hydroxyl-Terminated Poly(ethylene
oxide): Effects of Protein Size and Charge", Colloids and Surfaces B:
Biointerfaces, vol. 33, pp. 111-120, 2004
[6] A. Roosjen, H.C. Mei, H.J. Busscher and W. Norde, "Microbial
Adhesion to Poly(ethylene oxide) Brushes: Influence of Polymer Chain
Length and Temperature", Langmuir, vol. 20, pp. 10949-10955, 2004
[7] W.Norde and D.Gage, "Interaction of BSA and human blood plasma
with PEO-tethered surfaces: influence of PEO chain length, grafting
density and temperature", Langmuir, vol. 20, pp. 4162-4167, 2004
[8] K.L.Prime and G.M.Whitesides, "Adsorption of Proteins onto Surfaces
Containing End-Attached Oligo( ethylene oxide): A Model System
Using Self-Assembled Monolayers", Journal American Chemistry
Society, vol. 115, pp. 10714-10721, 1993
[9] K.Uchida, H.Otsuka, M.Kaneko, K.Kataoka and Y.Nagasaki, "A
reactive poly (ethylene glycol) layer to achieve specific surface plasmon
resonance sensing with a high S/N: The substantial role of a short
underbrushed PEG layer in minimizing nonspecific adsorption",
Analytical Chemistry, vol. 77, pp. 1075-1080
[10] C.Yoshikawa, A.Goto. Y.Tsuji, T.Fukuda, T.Kimura, K.Yamamoto and
A.Kishida, "Protein repellency of well-defined, concentrated poly (2-
hydroxyethyl methacrylate) brushes by the size exclusion effect",
Macromolecules, vol. 39, pp. 2284-2290, 2006
[11] Y.J.Wu, R.B.Timmons, J.S.Jen and F.E.Molock, "Non-fouling surfaces
produced by gas phase pulsed plasma polymerization of an ultra low
molecular weight ethylene oxide containing monomer", Colloids and
surfaces B: Biointerfaces, vol. 18, pp. 235-248, 2000
[12] N.Weber, H.Peter, and J.Kohn, "Formation of viscoelastic protein layers
on polymeric surfaces relevant to platelet adhesion", Wiley InterScience,
pp. 420-427,2005
[13] F. Hook, J. Voros, M. Rodahl, R. Kurrat, P. Boni, J.J. Ramsden, M.
Textor, N.D. Spencer, P. Tengvall, J. Gold and B. Kasemo, "A
Comparative Study of Protein Adsorption on Titanium Oxide Surfaces
Using in situ Ellipsometry, Optical Waveguide Lightmode Spectroscopy
and Quartz Crystal Microbalance/Dissipation". Colloids and Surfaces B:
Biointerfaces, pp. 155-170, 2002.
[14] M.T. Muller, X. Yan, S. Lee, S.S. Perry and N.D. Spencer, N.D. (2005).
"Lubrication Properties of a Brushlike Copolymer as a Function of the
Amount of Solvent Absorbed within the Brush". Macromolecules, pp.
5706-5713, 2005.
[15] I.M. Nnebe, R.D. Tilton, J.W. Schneider, "Direct Force Measurement of
the Stability of Poly(ethylene glycol)-Polyethylenimine Graft Films",
Journal of Colloid and Interface Science, vol. 276, pp. 306-316, 2004.
[16] R.Fukai. P.H.R.Dakwa and W.Chen, "Strategies toward biocompatible
artificial implants:grafting of functionalized poly(ethylene glycol)s to
poly(ethylene terephthalate) surfaces", Journal of Polymer Science:Part
A:Polymer Chemistry. vol. 42, pp. 5389-5400, 2004.
[17] R. Michel, S. Pasche, M. Textor and D. G. Castner, "Influence of PEG
Architecture on Protein Adsorption and Conformation", Langmuir, vol.
21, pp. 12327-12332, 2005.
[18] A.Helparin, "Polymer brushes that resist adsorption of model
proteins:Design parameters", Langmuir, vol. 15, pp. 2525-2533, 1999
[19] N.Nath, J.Hyun, H.Ma and A.Chilkoti, "Surface Engineering for Control
of Protein and Cell Interactions", Surface Science, vol. 570, pp. 98-110,
2004.
[20] M.Malmsten, K.Emoto and J.M.V.Alstine, "Effect of chain density on
inhibition of protein adsorption by Poly(ethylene glycol) based
coatings", Journal of Colloidal and Interface Science, vol. 202, pp. 507-
517, 1998.