Influence of Differences of Heat Insulation Methods on Thermal Comfort of Apartment Buildings

The aim of this study is to analyze influence of differences of heat insulation methods on indoor thermal environment and comfort of apartment buildings. This study analyzes indoor thermal environment and comfort on units of apartment buildings using calculation software "THERB" and compares three different kinds of heat insulation methods. Those are outside insulation on outside walls, inside insulation on outside walls and interior insulation. In terms of indoor thermal environment, outside insulation is the best to stabilize room temperature. In winter, room temperature on outside insulation after heating is higher than other and it is kept 3-5 degrees higher through all night. But the surface temperature with outside insulation did not dramatically increase when heating was used, which was 3 to 5oC lower than the temperature with other insulation. The PMV of interior insulation fall nearly range of comfort when the heating and cooling was use.




References:
[1] Guideline of Housing Energy Conservation Standard Third edition by
Institute for Building Environment and Energy Conservation - July 2009.
[2] Expanded AMeDAS Weather Data from 1981 to 2000 by Architectural
Institute of Japan - August 2005.
[3] Journal of Architectural Knowledge September edition.
[4] Hasegawa, K. and other three authors. Consideration of Adequate
Insulation Levels for Apartment Houses in view of Indoor Thermal
Environment. Journal of Summaries of Technical Papers of Annual
Meeting Architectural Institute of Japan, 213-214.
[5] Architectural Environment Engineering by Morikita Publishing Co., Ltd -
June 1996.