Indoor Moisture Control of Auckland Houses with Different Ventilation Systems

Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. Auckland house design not only focus on winter thermal performance and indoor thermal condition, but also indoor moisture control, which is closely related to indirect health effects such as dust mites, fungi, etc. Most Auckland houses are designed to use temporary heating for winter indoor thermal comfort. Based on field study data of indoor microclimate conditions of two Auckland townhouses with a whole home mechanical ventilation system or a passive wind directional skylight vent, this study is to evaluate and compare indoor moisture conditions of two insulated townhouses only using temporary heating with different ventilation systems.


Authors:



References:
[1] A. V. Arundel, E. M. Sterling, J. H. Biggin and T.D. Sterling, “Indirect
health effects of relative humidity in indoor environments.”
Environmental Health Perspectives, vol. 65, no. 3, pp. 351-361, Mar.
1986.
[2] H. Hens, “Minimising Fungal Defacement,” ASHRAE Journal, October
2000, American Society of Heating, Refrigerating and Air-conditioning
Engineers, New York.
[3] B. Su, “A field study of mould growth and indoor health conditions in
Auckland dwellings.” Architectural Science Review, vol. 45, no. 4, pp.
275-284, Dec. 2002.
[4] B. Su, “Prevention of winter mould growth in housing,” Architectural
Science Review, vol. 49, no. 4, pp. 385-390, Dec. 2006.
[5] S. T. K. West, (2008) “Design and Development of Natural Ventilation
Products and Associated Improvement of Indoor Environment Quality,”
in Proceedings of the Conference on Sustainable Building SB08,
Melbourne, September 2008.
[6] B. Su, “House indoor thermal and health conditions with different
passive designs.” World Academy of Science, Engineering and
Technology, 66 (1), pp. 22-25.
[7] WHO, “Air quality guidelines for Europe 2000 - Second Edition WHO
Regional Publications”, European Series, N91, 2000.
[8] J. Sateru, “Finnish Society of Indoor Air Quality and Climate (2004)
Performance Criteria of Buildings for Health and Comfort”, CIB Task
Group TG42, published by CIB secretariat, No 292.
[9] DBH, “Compliance Document for New Zealand Building Code – Clause
G5 Interior Environment,” Wellington, New Zealand: Department of
Building and Housing, 2001.
[10] SANZ, “New Zealand Standard 4303-1990 Ventilation for Acceptable
Indoor Air Quality,” Wellington, New Zealand: Standards Association
of New Zealand, 1990.