Abstract: This study aimed to investigate PM10 emitted from different limestone mines in Saraburi province, Thailand. The blasting and crushing were the main processes selected for PM10 sampling. PM10 was collected in two mines including, a limestone mine for cement manufacturing (mine A) and a limestone mine for construction (mine B). The IMPACT samplers were used to collect PM10. At blasting, the points aligning with the upwind and downwind direction were assigned for the sampling. The ranges of PM10 concentrations at mine A and B were 0.267-5.592 and 0.130-0.325 mg/m³, respectively, and the concentration at blasting from mine A was significantly higher than mine B (p < 0.05). During crushing at mine A, the PM10 concentration with the range of 1.153-3.716 and 0.085-1.724 mg/m³ at crusher and piles in respectively were observed whereas the PM10 concentration measured at four sampling points in mine B, including secondary crusher, tertiary crusher, screening point, and piles, were ranged 1.032-16.529, 10.957-74.057, 0.655-4.956, and 0.169-1.699 mg/m³, respectively. The emission of PM10 concentration at the crushing units was different in the ranges depending on types of machine, its operation, dust collection and control system, and environmental conditions.
Abstract: Gas release from the pipelines is one of the main factors in the gas industry accidents. Released gas ejects from the pipeline as a free jet and in the growth process, the fuel gets mixed with the ambient air. Accordingly, an accidental spark will release the chemical energy of the mixture with an explosion. Gas explosion damages the equipment and endangers the life of staffs. So due to importance of safety in gas industries, prevision of accident can reduce the number of the casualties. In this paper, natural gas leakages from the low pressure pipelines are studied in two steps: 1) the simulation of mixing process and identification of flammable zones and 2) the simulation of wind effects on the mixing process. The numerical simulations were performed by using the finite volume method and the pressure-based algorithm. Also, for the grid generation the structured method was used. The results show that, in just 6.4 s after accident, released natural gas could penetrate to 40 m in vertical and 20 m in horizontal direction. Moreover, the results show that the wind speed is a key factor in dispersion process. In fact, the wind transports the flammable zones into the downstream. Hence, to improve the safety of the people and human property, it is preferable to construct gas facilities and buildings in the opposite side of prevailing wind direction.
Abstract: The study aims to understand the surface pressure distribution around the bodies such as the suction pressure in the leading edge on the top and side-face when the aspect ratio of bodies and the wind direction are changed, respectively. We carried out the wind tunnel measurement and numerical simulation around a series of rectangular bodies (40d×80w×80h, 80d×80w×80h, 160d×80w×80h, 80d×40w×80h and 80d×160w×80h in mm3) placed in a deep turbulent boundary layer. Based on a modern numerical platform, the Navier-Stokes equation with the typical 2-equation (k-ε model) and the DES (Detached Eddy Simulation) turbulence model has been calculated, and they are both compared with the measurement data. Regarding the turbulence model, the DES model makes a better prediction comparing with the k-ε model, especially when calculating the separated turbulent flow around a bluff body with sharp edged corner. In order to observe the effect of wind direction on the pressure variation around the cube (e.g., 80d×80w×80h in mm), it rotates at 0º, 10º, 20º, 30º, and 45º, which stands for the salient wind directions in the tunnel. The result shows that the surface pressure variation is highly dependent upon the approaching wind direction, especially on the top and the side-face of the cube. In addition, the transverse width has a substantial effect on the variation of surface pressure around the bodies, while the longitudinal length has little or no influence.
Abstract: As a great source of renewable energy, solar energy is considered to be one of the most important in the world, since it will be one of solutions cover the energy shortage in the future. Photovoltaic (PV) is the most popular and widely used among solar energy technologies. However, PV efficiency is fairly low and remains somewhat expensive. High temperature has a negative effect on PV efficiency and cooling system for these panels is vital, especially in warm weather conditions. This paper presents the results of a simulation study carried out on silicon solar cells to assess the effects of elevation on enhancing the efficiency of solar panels. The study included four different terrains. The study also took into account the direction of the wind hitting the solar panels. To ensure the simulation mimics reality, six silicon solar panels are designed in two columns and three rows, facing to the south at an angle of 30 o. The elevations are assumed to change from 10 meters to 200 meters. The results show that maximum increase in efficiency occurs when the wind comes from the north, hitting the back of the panels.
Abstract: The present study was aimed in assessing the heavy metal pollution of the soils around Agarak copper-molybdenum mine complex and related environmental risks. This mine complex is located in the south-east part of Armenia, and the present study was conducted in 2013. The soils of the five riskiest sites of this region were studied: surroundings of the open mine, the sites adjacent to processing plant of Agarak copper-molybdenum mine complex, surroundings of Darazam active tailing dump, the recultivated tailing dump of “ravine - 2”, and the recultivated tailing dump of “ravine - 3”. The mountain cambisol was the main soil type in the study sites. The level of soil contamination by heavy metals was assessed by Contamination factors (Cf), Degree of contamination (Cd), Geoaccumulation index (I-geo) and Enrichment factor (EF). The distribution pattern of trace metals in the soil profile according to Cf, Cd, I-geo and EF values shows that the soil is much polluted. Almost in all studied sites, Cu, Mo, Pb, and Cd were the main polluting heavy metals, and this was conditioned by Agarak copper-molybdenum mine complex activity. It is necessary to state that the pollution problem becomes pressing as some parts of these highly polluted region are inhabited by population, and agriculture is highly developed there; therefore, heavy metals can be transferred into human bodies through food chains and have direct influence on public health. Since the induced pollution can pose serious threats to public health, further investigations on soil and vegetation pollution are recommended. Finally, Cf calculating based on distance from the pollution source and the wind direction can provide more reasonable results.
Abstract: We present in this work our model of road traffic
emissions (line sources) and dispersion of these emissions, named
DISPOLSPEM (Dispersion of Poly Sources and Pollutants Emission
Model). In its emission part, this model was designed to keep the
consistent bottom-up and top-down approaches. It also allows to
generate emission inventories from reduced input parameters being
adapted to existing conditions in Morocco and in the other developing
countries. While several simplifications are made, all the performance
of the model results are kept. A further important advantage of
the model is that it allows the uncertainty calculation and emission
rate uncertainty according to each of the input parameters. In the
dispersion part of the model, an improved line source model has
been developed, implemented and tested against a reference solution.
It provides improvement in accuracy over previous formulas of line
source Gaussian plume model, without being too demanding in terms
of computational resources. In the case study presented here, the
biggest errors were associated with the ends of line source sections;
these errors will be canceled by adjacent sections of line sources
during the simulation of a road network. In cases where the wind
is parallel to the source line, the use of the combination discretized
source and analytical line source formulas minimizes remarkably the
error. Because this combination is applied only for a small number
of wind directions, it should not excessively increase the calculation
time.
Abstract: When a building is located in an urban area, it is
exposed to a wind of different characteristics then wind over an open
terrain. This is development of turbulent wake region behind an
upstream building. The interaction with upstream building can
produce significant changes in the response of the tall building. Here,
in this paper, an attempt has been made to study wind induced
interference effects on tall building. In order to study wind induced
interference effect (IF) on Tall Building, initially a tall building
(which is termed as Principal Building now on wards) with square
plan shape has been considered with different Height to Width Ratio
and total drag force is obtained considering different terrain
conditions as well as different incident wind direction. Then total
drag force on Principal Building is obtained by considering adjacent
building which is termed as Interfering Building now on wards with
different terrain conditions and incident wind angle. To execute
study, Computational Fluid Dynamics (CFD) Code namely Fluent
and Gambit have been used.
Abstract: This paper presents long term wind data analysis in terms of annual and diurnal variations at different areas of Libya. The data of the wind speed and direction are taken each ten minutes for a period, at least two years, are used in the analysis. ‘WindPRO’ software and Excel workbook were used for the wind statistics and energy calculations. As for Darnah, average speeds are 10m, 20m and 40m and 6.57 m/s, 7.18 m/s, and 8.09 m/s, respectively. Highest wind speeds are observed at SSW, followed by S, WNW and NW sectors. Lowest wind speeds are observed between N and E sectors. Most frequent wind directions are NW and NNW. Hence, wind turbines can be installed against these directions. The most powerful sector is NW (31.3% of total expected wind energy), followed by 17.9% SSW, 11.5% NNW and 8.2% WNW
In Excel workbook, an estimation of annual energy yield at position of Derna, Al-Maqrun, Tarhuna and Al-Asaaba meteorological mast has been done, considering a generic wind turbine of 1.65 MW. (mtORRES, TWT 82-1.65MW) in position of meteorological mast. Three other turbines have been tested and a reduction of 18% over the net AEP. At 80m, the estimation of energy yield for Derna, Al- Maqrun, Tarhuna and Asaaba is 6.78 GWh or 3390 equivalent hours, 5.80 GWh or 2900 equivalent hours, 4.91 GWh or 2454 equivalent hours and 5.08 GWh or 2541 equivalent hours respectively. It seems a fair value in the context of a possible development of a wind energy project in the areas, considering a value of 2400 equivalent hours as an approximate limit to consider a wind warm economically profitable. Furthermore, an estimation of annual energy yield at positions of Misalatha, Azizyah and Goterria meteorological mast has been done, considering a generic wind turbine of 2 MW. We found that, at 80 m the estimation of energy yield is 3.12 GWh or 1557 equivalent hours, 4.47 GWh or 2235 equivalent hours and 4.07GWh or 2033 respectively.
It seems a very poor value in the context of possible development of a wind energy project in the areas, considering a value of 2400 equivalent hours as an approximate limit to consider a wind warm economically profitable. Anyway, more data and a detailed wind farm study would be necessary to draw conclusions.
Abstract: This study investigated the relationship between urban
and rural ozone concentrations and quantified the extent to which
ambient rural conditions and the concentrations of other pollutants
can be used to predict urban ozone concentrations. The study
describes the variations of ozone in weekday and weekends as well as
the daily maximum recorded at selected monitoring stations. The
results showed that Putrajaya station had the highest concentrations
of O3 on weekend due the titration of NO during the weekday.
Additionally, Jerantut had the lowest average concentration with a
reading value high on Wednesdays. The comparisons of average and
maximum concentrations of ozone for the three stations showed that
the strongest significant correlation is recorded in Jerantut station
with the value R2= 0.769. Ozone concentrations originating from a
neighbouring urban site form a better predictor to the urban ozone
concentrations than widespread rural ozone at some levels of
temporal averaging. It is found that in urban and rural of Malaysian
peninsular, the concentration of ozone depends on the concentration
of NOx and seasonal meteorological factors. The HYSPLIT Model
(the northeast monsoon) showed that the wind direction can also
influence the concentration of ozone in the atmosphere in the studied
areas.
Abstract: The construction of a civil structure inside a urban
area inevitably modifies the outdoor microclimate at the building
site. Wind speed, wind direction, air pollution, driving rain, radiation
and daylight are some of the main physical aspects that are subjected
to the major changes. The quantitative amount of these modifications
depends on the shape, size and orientation of the building and on its
interaction with the surrounding environment.The flow field over a
flat roof model building has been numerically investigated in order to
determine two-dimensional CFD guidelines for the calculation of the
turbulent flow over a structure immersed in an atmospheric boundary
layer. To this purpose, a complete validation campaign has been
performed through a systematic comparison of numerical simulations
with wind tunnel experimental data.Several turbulence models and
spatial node distributions have been tested for five different vertical
positions, respectively from the upstream leading edge to the
downstream bottom edge of the analyzed model. Flow field
characteristics in the neighborhood of the building model have been
numerically investigated, allowing a quantification of the capabilities
of the CFD code to predict the flow separation and the extension of
the recirculation regions.The proposed calculations have allowed the
development of a preliminary procedure to be used as a guidance in
selecting the appropriate grid configuration and corresponding
turbulence model for the prediction of the flow field over a twodimensional
roof architecture dominated by flow separation.
Abstract: The flow filed around a flatted-roof compound has
been investigated by means of 2D and 3D numerical simulations. A
constant wind velocity profile, based both on the maximum reference
wind speed in the building site (peak gust speed worked out for a 50-
year return period) and on the local roughness coefficient, has been
simulated in order to determine the wind-induced loads on top of the
roof. After determining the influence of the incoming wind directions
on the induced roof loads, a 2D analysis of the most severe load
condition has been performed, achieving a numerical quantification
of the expected wind-induced forces on the PV panels on top of the
roof.
Abstract: Wind catchers are traditional natural ventilation
systems attached to buildings in order to ventilate the indoor air. The
most common type of wind catcher is four sided one which is
capable to catch wind in all directions. CFD simulation is the perfect
way to evaluate the wind catcher performance. The accuracy of CFD
results is the issue of concern, so sensitivity analyses is crucial to
find out the effect of different settings of CFD on results. This paper
presents a series of 3D steady RANS simulations for a generic
isolated four-sided wind catcher attached to a room subjected to wind
direction ranging from 0º to 180º with an interval of 45º. The CFD
simulations are validated with detailed wind tunnel experiments. The
influence of an extensive range of computational parameters is
explored in this paper, including the resolution of the computational
grid, the size of the computational domain and the turbulence model.
This study found that CFD simulation is a reliable method for wind
catcher study, but it is less accurate in prediction of models with non
perpendicular wind directions.
Abstract: Three dimensional simulations are carried out to estimate the effect of wind direction, wind speed and geometry on the flow and dispersion of vehicular pollutant in a street canyon. The pollutant sources are motor vehicles passing between the two buildings. Suitable emission factors for petrol and diesel vehicles at varying vehicle speed are used for the estimation of the rate of emission from the streets. The dispersion of automobile pollutant released from the street is simulated by introducing vehicular emission source term as a fixed-flux boundary condition at the ground level over the road. The emission source term is suitably calculated by adopting emission factors from literature for varying conditions of street traffic. It is observed that increase in wind angle disturbs the symmetric pattern of pollution distribution along the street length. The concentration increases in the far end of the street as compared to the near end.
Abstract: The flow field over a three dimensional pole barn
characterized by a cylindrical roof has been numerically investigated.
Wind pressure and viscous loads acting on the agricultural building
have been analyzed for several incoming wind directions, so as to
evaluate the most critical load condition on the structure. A constant
wind velocity profile, based on the maximum reference wind speed in
the building site (peak gust speed worked out for 50 years return
period) and on the local roughness coefficient, has been simulated.
In order to contemplate also the hazard due to potential air
wedging between the stored hay and the lower part of the ceiling, the
effect of a partial filling of the barn has been investigated.
The distribution of wind-induced loads on the structure have been
determined, allowing a numerical quantification of the effect of wind
direction on the induced stresses acting on a hemicylindrical roof.
Abstract: Kish Islands in South of Iran is located in coastal
water near Hormozgan Province. Based on the wind 3-hour statistics
in Kish station, the mean annual windspeed in this Island is 8.6 knot
(4.3 m/s). The maximum windspeed recorded in this stations 47 knot
(23.5 m/s). In 45.7 percent of recorded times, windspeed has been
Zero or less than 8 knot which is not suitable to use the wind energy.
But in 54.3 percent of recorded times, windspeed has been more than
8 knot and suitable to use wind energy to run turbines. In 40.2
percent of recorded times, windspeed has been between 8 to 16 knot,
in 13 percent of times between 16 to 24 knot and in 1 percent of
times it has been higher than 24 knot. In this station, the direction of
winds higher than 8 is west and wind direction in Kish station is
stable in most times of the year.With regard to high – speed and
stable direction winds during the year and also shallow coasts near
this is land, it is possible to build offshore wind farms near Kish
Island and utilize wind energy produce the electricity required in this
Island during most of the year.
Abstract: This paper presents an evaluation of the wind potential in the area of the Lagoon of Venice (Italy). A full anemometric campaign of 2 year measurements, performed by the "Osservatorio Bioclimatologico dell'Ospedale al Mare di Venezia" has been analyzed to obtain the Weibull wind speed distribution and the main wind directions. The annual energy outputs of two candidate horizontal-axis wind turbines (“Aventa AV-7 LoWind" and “Gaia Wind 133-11kW") have been estimated on the basis of the computed Weibull wind distribution, registering a better performance of the former turbine, due to a higher ratio between rotor swept area and rated power of the electric generator, determining a lower cut-in wind speed.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. Auckland house design not only focus on winter thermal performance and indoor thermal condition, but also indoor moisture control, which is closely related to indirect health effects such as dust mites, fungi, etc. Most Auckland houses are designed to use temporary heating for winter indoor thermal comfort. Based on field study data of indoor microclimate conditions of two Auckland townhouses with a whole home mechanical ventilation system or a passive wind directional skylight vent, this study is to evaluate and compare indoor moisture conditions of two insulated townhouses only using temporary heating with different ventilation systems.
Abstract: Over 90% of the world trade is carried by the
international shipping industry. As most of the countries are
developing, seaborne trade continues to expand to bring benefits for
consumers across the world. Studies show that world trade will
increase 70-80% through shipping in the next 15-20 years. Present
global fleet of 70000 commercial ships consumes approximately 200
million tonnes of diesel fuel a year and it is expected that it will be
around 350 million tonnes a year by 2020. It will increase the
demand for fuel and also increase the concentration of CO2 in the
atmosphere. So, it-s essential to control this massive fuel
consumption and CO2 emission. The idea is to utilize a diesel-wind
hybrid system for ship propulsion. Use of wind energy by installing
modern wing-sails in ships can drastically reduce the consumption of
diesel fuel. A huge amount of wind energy is available in oceans.
Whenever wind is available the wing-sails would be deployed and
the diesel engine would be throttled down and still the same forward
speed would be maintained. Wind direction in a particular shipping
route is not same throughout; it changes depending upon the global
wind pattern which depends on the latitude. So, the wing-sail
orientation should be such that it optimizes the use of wind energy.
We have made a computer programme in which by feeding the data
regarding wind velocity, wind direction, ship-motion direction; we
can find out the best wing-sail position and fuel saving for
commercial ships. We have calculated net fuel saving in certain
international shipping routes, for instance, from Mumbai in India to
Durban in South Africa. Our estimates show that about 8.3% diesel
fuel can be saved by utilizing the wind. We are also developing an
experimental model of the ship employing airfoils (small scale wingsail)
and going to test it in National Wind Tunnel Facility in IIT
Kanpur in order to develop a control mechanism for a system of
airfoils.