Abstract: Photoacoustic Tomography (PAT) is a promising medical imaging modality that combines optical imaging contrast with the spatial resolution of ultrasound imaging. It can also distinguish the changes in biological features. But, real-time PAT system should be confirmed due to photoacoustic effect for tissue. Thus, we have developed a real-time PAT system using a custom-developed data acquisition board and ultrasound linear probe. To evaluate performance of our system, phantom test was performed. As a result of those experiments, the system showed satisfactory performance and its usefulness has been confirmed. We monitored the degradation of inflammation which induced on the rat’s kidney using real-time PAT.
Abstract: In this paper, we present a new segmentation approach
for focal liver lesions in contrast enhanced ultrasound imaging. This
approach, based on a two-cluster Fuzzy C-Means methodology,
considers type-II fuzzy sets to handle uncertainty due to the image
modality (presence of speckle noise, low contrast, etc.), and to
calculate the optimum inter-cluster threshold. Fine boundaries are
detected by a local recursive merging of ambiguous pixels. The
method has been tested on a representative database. Compared to
both Otsu and type-I Fuzzy C-Means techniques, the proposed
method significantly reduces the segmentation errors.
Abstract: Medical imaging technology has experienced a
dramatic change in the last few years. Medical imaging refers to the
techniques and processes used to create images of the human body
(or parts thereof) for various clinical purposes such as medical
procedures and diagnosis or medical science including the study of
normal anatomy and function. With the growth of computers and
image technology, medical imaging has greatly influenced the
medical field. The diagnosis of a health problem is now highly
dependent on the quality and the credibility of the image analysis.
This paper deals with the various aspects and types of medical
imaging.
Abstract: Speckled images arise when coherent microwave,
optical, and acoustic imaging techniques are used to image an object, surface or scene. Examples of coherent imaging systems include synthetic aperture radar, laser imaging systems, imaging sonar
systems, and medical ultrasound systems. Speckle noise is a form of object or target induced noise that results when the surface of the object is Rayleigh rough compared to the wavelength of the illuminating radiation. Detection and estimation in images corrupted
by speckle noise is complicated by the nature of the noise and is not
as straightforward as detection and estimation in additive noise. In
this work, we derive stochastic models for speckle noise, with an emphasis on speckle as it arises in medical ultrasound images. The
motivation for this work is the problem of segmentation and tissue classification using ultrasound imaging. Modeling of speckle in this
context involves partially developed speckle model where an underlying Poisson point process modulates a Gram-Charlier series
of Laguerre weighted exponential functions, resulting in a doubly
stochastic filtered Poisson point process. The statistical distribution of partially developed speckle is derived in a closed canonical form.
It is observed that as the mean number of scatterers in a resolution cell is increased, the probability density function approaches an
exponential distribution. This is consistent with fully developed speckle noise as demonstrated by the Central Limit theorem.
Abstract: The work describes the use of a synthetic transmit
aperture (STA) with a single element transmitting and all elements
receiving in medical ultrasound imaging. STA technique is a novel
approach to today-s commercial systems, where an image is acquired
sequentially one image line at a time that puts a strict limit on the
frame rate and the amount of data needed for high image quality. The
STA imaging allows to acquire data simultaneously from all
directions over a number of emissions, and the full image can be
reconstructed.
In experiments a 32-element linear transducer array with 0.48 mm
inter-element spacing was used. Single element transmission aperture
was used to generate a spherical wave covering the full image region.
The 2D ultrasound images of wire phantom are presented obtained
using the STA and commercial ultrasound scanner Antares to
demonstrate the benefits of the SA imaging.
Abstract: The paper presents the study of synthetic transmit
aperture method applying the Golay coded transmission for medical
ultrasound imaging. Longer coded excitation allows to increase the
total energy of the transmitted signal without increasing the peak
pressure. Signal-to-noise ratio and penetration depth are improved
maintaining high ultrasound image resolution.
In the work the 128-element linear transducer array with 0.3 mm
inter-element spacing excited by one cycle and the 8 and 16-bit
Golay coded sequences at nominal frequencies 4 MHz was used.
Single element transmission aperture was used to generate a spherical
wave covering the full image region and all the elements received the
echo signals. The comparison of 2D ultrasound images of the wire
phantom as well as of the tissue mimicking phantom is presented to
demonstrate the benefits of the coded transmission. The results were
obtained using the synthetic aperture algorithm with transmit and
receive signals correction based on a single element directivity
function.
Abstract: In the paper the study of synthetic transmit aperture
method applying the Golay coded transmission for medical
ultrasound imaging is presented. Longer coded excitation allows to
increase the total energy of the transmitted signal without increasing
the peak pressure. Moreover signal-to-noise ratio and penetration
depth are improved while maintaining high ultrasound image
resolution. In the work the 128-element linear transducer array with
0.3 mm inter-element spacing excited by one cycle and the 8 and 16-
bit Golay coded sequences at nominal frequency 4 MHz was used. To
generate a spherical wave covering the full image region a single
element transmission aperture was used and all the elements received
the echo signals. The comparison of 2D ultrasound images of the
tissue mimicking phantom and in vitro measurements of the beef liver
is presented to illustrate the benefits of the coded transmission. The
results were obtained using the synthetic aperture algorithm with
transmit and receive signals correction based on a single element
directivity function.