Abstract: Headed stud shear connections are widely used in the junction or embedded zone of hybrid girder to achieve whole composite action with continuity that can sustain steel-concrete interfacial tensile and shear forces. In Japan, Japan Road Association (JRA) specifications are used for hybrid girder design that utilizes very low level of stud capacity than those of American Institute of Steel Construction (AISC) specifications, Japan Society of Civil Engineers (JSCE) specifications and EURO code. As low design shear strength is considered in design of connections, the time dependent shear behavior due to sustained external loading is not considered, even not fully studied. In this study, a finite element approach was used to evaluate the time dependent shear behavior for headed studs used as connections at the junction. This study clarified, how the sustained loading distinctively impacted on changing the interfacial shear of connections with time which was sensitive to lodging history, positions of flanges, neighboring studs, position of prestress bar and reinforcing bar, concrete strength, etc. and also identified a shear influence area. Stud strength was also confirmed through pushout tests. The outcome obtained from the study may provide an important basis and reference data in designing connections of hybrid girders with enhanced stud capacity with due consideration of their long-term shear behavior.
Abstract: This paper comprises an experimental investigation into the structural performance of cold formed steel (CFS) and timber board composite floor systems. The tests include a series of small-scale pushout tests and full-scale bending tests carried out using a refined loading system to simulate uniformly distributed constant load. The influence of connection details (screw spacing and adhesives) on floor performance was investigated. The results are then compared to predictions from relevant existing models for composite floor systems. The results of this research demonstrate the significant benefits of considering the composite action of the boards in floor design. Depending on connection detail, an increase in flexural stiffness of up to 40% was observed in the floor system, when compared to designing joists individually.
Abstract: The economic use and ease of construction of profiled
deck composite slab is marred with the complex and un-economic
strength verification required for the serviceability and general safety
considerations. Beside these, albeit factors such as shear span length,
deck geometries and mechanical frictions greatly influence the
longitudinal shear strength, that determines the ultimate strength of
profiled deck composite slab, and number of methods available for its
determination; partial shear and slope-intercept are the two methods
according to Euro-code 4 provision. However, the complexity
associated with shear behavior of profiled deck composite slab, the
use of these methods in determining the load carrying capacities of
such slab yields different and conflicting values. This couple with the
time and cost constraint associated with the strength verification is a
source of concern that draws more attentions nowadays, the issue is
critical. Treating some of these known shear strength influencing
factors as random variables, the load carrying capacity violation of
profiled deck composite slab from the use of the two-methods
defined according to Euro-code 4 are determined using reliability
approach, and comparatively studied. The study reveals safety values
from the use of m-k method shows good standing compared with that
from the partial shear method.
Abstract: In order to apply partially filled steel grid composite deck as the horizontal supporting structure of various kinds of infrastructures, the variation of its flexural strength according to design parameters such as cross and longitudinal bars constituting the steel grid and the type of shear connection is evaluated and compared experimentally. The result shows that the design sensitivity of the deck to the spacing of the cross bars is insignificant in the case of structure with low risk of punching failure or without load distribution problem. By means of shear connection composed by transverse rebar and longitudinal bar without additional shear stud bolts, the complete interaction between steel grid and concrete slab is able to be achieved and the composite deck can develop its bending resistance capacity.