Preserved Relative Differences between Regions of Different Thermal Scans

Rheumatoid Arthritis patients have swelling and pain in joints of the hand. The regions where the patient feels pain also show increased body temperature. Thermal cameras can be used to detect the rise in temperature of the affected regions. To monitor the progression of Rheumatoid Arthritis, patients must visit the clinic regularly for scanning and examination. After scanning and evaluation, the dosage of the medicine is regulated accordingly. To monitor the disease progression over time, the correlation of the images between different visits must be established. It has been observed that the thermal measurements do not remain the same over time, even within a single scanning, when low-cost thermal cameras are used. In some situations, temperatures can vary as much as 2◦C within the same scanning sequence. In this paper, it has been shown that although the absolute temperature varies over time, the relative difference between different regions remains similar. Results have been computed over four scanning sequences and are presented.

Procedure to Use Quantitative Bone-Specific SPECT/CT in North Karelia Central Hospital

This study aimed to describe procedures that we developed to use in the quantitative, bone-specific SPECT/CT at our hospital. Our procedures included the following questions for choosing imaging protocols, which were based on a clinical doctor's referral: (1) Is she/he a cancer patient or not? (2) Are there any indications of inflammatory rheumatoid arthritis? We performed about 1,106 skeletal scintigraphies over two years. About 394 patients were studied with quantitative bone-specific single-photon emission computed tomography/computerized tomography (SPECT/CT) (i.e., about 36% of all bone scintigraphies). Approximately 64% of the patients were studied using the conventional Anterior-Posterior/Posterior-Anterior imaging. Our procedure has improved efficiency and decreased cycle times.

Role of Inflammatory Markers in Arthritic Rats Treated with Ethanolic Bark Extract of Albizia procera

Rheumatoid arthritis (RA) is a chronic, progressive, systemic inflammatory disorder affecting the synovial joints and typically producing symmetrical arthritis that leads to joint destruction, which is responsible for the deformity and disability. Despite improvements in the treatment of RA over the past decade, there still is a need for new therapeutic agents that are efficacious, less expensive, and free of severe adverse reactions. The present study aimed to investigate role of inflammatory markers in arthritic rats treated with ethanolic bark extract of Albizia procera. The protective effect of ethanolic bark extract of Albizia procera against complete Freund’s adjuvant (CFA) induced arthritis in rats. Arthritis was induced by an intradermal injection of 0.1 ml FCA in the foot pad of left hind limb of rats. ETBE (100 and 200 mg/kg b.wt./p.o) and the reference drug diclofenac (25 mg/kg b.wt./p.o) were administered to arthritic rats. Paw volume was measured for all the animals before inducing arthritis and thereafter once in seven days by using plethysmometer for 42 days. Gene expression of inflammatory markers such as IL-1β and IL-10 were investigated in paw tissues. Up regulation of IL-1β and Down regulation IL-10 were observed in CFA injected rats when compared to normal rats. ETBE attenuated these alterations dose dependently when compared to the vehicle treated rats. These results provide insights into the mechanism of anti-arthritic activity, and unravel potential therapeutic use of Albizia procera in arthritis.

Determination of Cyclic Citrullinated Peptide Antibodies on Quartz Crystal Microbalance Based Nanosensors

In this study, we have focused our attention on combining of molecular imprinting into nanofilms and QCM nanosensor approaches and producing QCM nanosensor for anti- CCP, chosen as model protein, using anti-CCP imprinted nanofilms. The nonimprinted nanosensor was also prepared to evaluate the selectivity of the imprinted nanosensor. Anti-CCP imprinted QCM nanosensor was tested for real time detection of anti-CCP from aqueous solution. The kinetic and affinity studies were determined by using anti-CCP solutions with different concentrations. The responses related with mass shifts (%m) and frequency shifts (%f) were used to evaluate adsorption properties. To show the selectivity of the anti-CCP imprinted QCM nanosensor, competitive adsorption of anti-CCP and IgM was investigated. The results indicate that anti- CCP imprinted QCM nanosensor has higher adsorption capabilities for anti-CCP than for IgM, due to selective cavities in the polymer structure.

Intelligent Assistive Methods for Diagnosis of Rheumatoid Arthritis Using Histogram Smoothing and Feature Extraction of Bone Images

Advances in the field of image processing envision a new era of evaluation techniques and application of procedures in various different fields. One such field being considered is the biomedical field for prognosis as well as diagnosis of diseases. This plethora of methods though provides a wide range of options to select from, it also proves confusion in selecting the apt process and also in finding which one is more suitable. Our objective is to use a series of techniques on bone scans, so as to detect the occurrence of rheumatoid arthritis (RA) as accurately as possible. Amongst other techniques existing in the field our proposed system tends to be more effective as it depends on new methodologies that have been proved to be better and more consistent than others. Computer aided diagnosis will provide more accurate and infallible rate of consistency that will help to improve the efficiency of the system. The image first undergoes histogram smoothing and specification, morphing operation, boundary detection by edge following algorithm and finally image subtraction to determine the presence of rheumatoid arthritis in a more efficient and effective way. Using preprocessing noises are removed from images and using segmentation, region of interest is found and Histogram smoothing is applied for a specific portion of the images. Gray level co-occurrence matrix (GLCM) features like Mean, Median, Energy, Correlation, Bone Mineral Density (BMD) and etc. After finding all the features it stores in the database. This dataset is trained with inflamed and noninflamed values and with the help of neural network all the new images are checked properly for their status and Rough set is implemented for further reduction.

A New Gateway for Rheumatoid Arthritis: COXIBs with an Improved Cardiovascular Profile

Today COXIBs are used in the treatment of arthritis and many other painful conditions in selected patients with high gastrointestinal risk and low cardiovascular (CV) risk. Previously, we have identified an unexpected mechanism of action of a traditional non-steroidal anti-inflammatory drug (NSAID) (diclofenac) and a specific inhibitor of cyclooxygenase-2 (COXIB) (lumiracoxib) demonstrating that they possess weak competitive antagonism at the thromboxane receptor (TP). We hypothesize that modifying the structure of a known COXIB so that it becomes also a more potent TP antagonist will preserve the anti-inflammatory and gastrointestinal safety typical of COXIBs and prevent the CV risk associated with long term therapy.

Highly Sensitive Label Free Biosensor for Tumor Necrosis Factor

We present a label-free biosensor based on electrochemical impedance spectroscopy for the detection of proinflammatory cytokine Tumor Necrosis Factor (TNF-α). Secretion of TNF-α has been correlated to the onset of various diseases including rheumatoid arthritis, Crohn-s disease etc. Gold electrodes were patterned on a silicon substrate and self assembled monolayer of dithiobis-succinimidyl propionate was used to develop the biosensor which achieved a detection limit of ~57fM. A linear relationship was also observed between increasing TNF-α concentrations and chargetransfer resistance within a dynamic range of 1pg/ml – 1ng/ml.