Abstract: Accurate determination of wind turbine performance is necessary for economic operation of a wind farm. At present, the procedure to carry out the power performance verification of wind turbines is based on a standard of the International Electrotechnical Commission (IEC). In this paper, nonparametric statistical inference is applied to designing a simple, inexpensive method of verifying the power performance of a wind turbine. A statistical test is explained, examined, and the adequacy is tested over real data. The methods use the information that is collected by the SCADA system (Supervisory Control and Data Acquisition) from the sensors embedded in the wind turbines in order to carry out the power performance verification of a wind farm. The study has used data on the monthly output of wind farm in the Republic of Macedonia, and the time measuring interval was from January 1, 2016, to December 31, 2016. At the end, it is concluded whether the power performance of a wind turbine differed significantly from what would be expected. The results of the implementation of the proposed methods showed that the power performance of the specific wind farm under assessment was acceptable.
Abstract: This paper presents the performance characteristics of
Darrieus-type vertical axis wind turbine (VAWT) with NACA airfoil
blades. The performance of Darrieus-type VAWT can be
characterized by torque and power. There are various parameters
affecting the performance such as chord length, helical angle, pitch
angle and rotor diameter. To estimate the optimum shape of Darrieustype
wind turbine in accordance with various design parameters, we
examined aerodynamic characteristics and separated flow occurring
in the vicinity of blade, interaction between flow and blade, and
torque and power characteristics derived from it. For flow analysis,
flow variations were investigated based on the unsteady RANS
(Reynolds-averaged Navier-Stokes) equation. Sliding mesh algorithm
was employed in order to consider rotational effect of blade. To
obtain more realistic results we conducted experiment and numerical
analysis at the same time for three-dimensional shape. In addition,
several parameters (chord length, rotor diameter, pitch angle, and
helical angle) were considered to find out optimum shape design and
characteristics of interaction with ambient flow. Since the NACA
airfoil used in this study showed significant changes in magnitude of
lift and drag depending on an angle of attack, the rotor with low drag,
long cord length and short diameter shows high power coefficient in
low tip speed ratio (TSR) range. On the contrary, in high TSR range,
drag becomes high. Hence, the short-chord and long-diameter rotor
produces high power coefficient. When a pitch angle at which airfoil
directs toward inside equals to -2° and helical angle equals to 0°,
Darrieus-type VAWT generates maximum power.
Abstract: The mathematical analysis on radiation obtained and
the development of the solar photovoltaic (PV) array groundwater
pumping is needed in the rural areas of Thohoyandou for sizing and
power performance subject to the climate conditions within the area.
A simple methodology approach is developed for the directed
coupled solar, controller and submersible ground water pump system.
The system consists of a PV array, pump controller and submerged
pump, battery backup and charger controller. For this reason, the
theoretical solar radiation is obtained for optimal predictions and
system performance in order to achieve different design and
operating parameters. Here the examination of the PV schematic
module in a Direct Current (DC) application is used for obtainable
maximum solar power energy for water pumping. In this paper, a
simple efficient photovoltaic water pumping system is presented with
its theoretical studies and mathematical modeling of photovoltaics
(PV) system.