Abstract: This paper is devoted to present the advances in the design of a prototype that is able to supervise the complex behavior of water quality parameters such as pH and temperature, via a real-time monitoring system. The current water quality tests that are performed in government water quality institutions in Mexico are carried out in problematic locations and they require taking manual samples. The water samples are then taken to the institution laboratory for examination. In order to automate this process, a water quality monitoring system based on wireless sensor networks is proposed. The system consists of a sensor node which contains one pH sensor, one temperature sensor, a microcontroller, and a ZigBee radio, and a base station composed by a ZigBee radio and a PC. The progress in this investigation shows the development of a water quality monitoring system. Due to recent events that affected water quality in Mexico, the main motivation of this study is to address water quality monitoring systems, so in the near future, a more robust, affordable, and reliable system can be deployed.
Abstract: Photoplethysmography is a simple measurement of the
variation in blood volume in tissue. It detects the pulse signal of heart
beat as well as the low frequency signal of vasoconstriction and
vasodilation. The transmission type measurement is limited to only a
few specific positions for example the index finger that have a short
path length for light. The reflectance type measurement can be
conveniently applied on most parts of the body surface. This study
analyzed the factors that determine the quality of reflectance
photoplethysmograph signal including the emitter-detector distance,
wavelength, light intensity, and optical properties of skin tissue.
Light emitting diodes (LEDs) with four different visible
wavelengths were used as the light emitters. A phototransistor was
used as the light detector. A micro translation stage adjusts the
emitter-detector distance from 2 mm to 15 mm.
The reflective photoplethysmograph signals were measured on
different sites. The optimal emitter-detector distance was chosen to
have a large dynamic range for low frequency drifting without signal
saturation and a high perfusion index. Among these four wavelengths,
a yellowish green (571nm) light with a proper emitter-detection
distance of 2mm is the most suitable for obtaining a steady and reliable
reflectance photoplethysmograph signal
Abstract: A measurement system for pH array sensors is
introduced to increase accuracy, and decrease non-ideal effects
successfully. An array readout circuit reads eight potentiometric
signals at the same time, and obtains an average value. The deviation
value or the extreme value is counteracted and the output voltage is a
relatively stable value. The errors of measuring pH buffer solutions are
decreased obviously with this measurement system, and the non-ideal
effects, drift and hysteresis, are lowered to 1.638mV/hr and 1.118mV,
respectively. The efficiency and stability are better than single sensor.
The whole sensing characteristics are improved.
Abstract: Fuzzy logic system (FLS) is used in this study to
predict the tractive performance in terms of traction force, and
motion resistance for an intelligent air cushion track vehicle while it
operates in the swamp peat. The system is effective to control the
intelligent air –cushion system with measuring the vehicle traction
force (TF), motion resistance (MR), cushion clearance height (CH)
and cushion pressure (CP). Ultrasonic displacement sensor, pull-in
solenoid electromagnetic switch, pressure control sensor, micro
controller, and battery pH sensor are incorporated with the Fuzzy
logic system to investigate experimentally the TF, MR, CH, and CP.
In this study, a comparison for tractive performance of an intelligent
air cushion track vehicle has been performed with the results obtained
from the predicted values of FLS and experimental actual values. The
mean relative error of actual and predicted values from the FLS
model on traction force, and total motion resistance are found as 5.58
%, and 6.78 % respectively. For all parameters, the relative error of
predicted values are found to be less than the acceptable limits. The
goodness of fit of the prediction values from the FLS model on TF,
and MR are found as 0.90, and 0.98 respectively.