Brief Review of the Self-Tightening, Left-Handed Thread

Loosening of bolted joints in rotating machines can adversely affect their performance, cause mechanical damage, and lead to injuries. In this paper, two potential loosening phenomena in rotating applications are discussed. First, ‘precession,’ is governed by thread/nut contact forces, while the second is based on inertial effects of the fastened assembly. These mechanisms are reviewed within the context of historical usage of left-handed fasteners in rotating machines which appears absent in the literature and common machine design texts. Historically, to prevent loosening of wheel nuts, vehicle manufacturers have used right-handed and left-handed threads on different sides of the vehicle, but most modern vehicles have abandoned this custom and only use right-handed, tapered lug nuts on all sides of the vehicle. Other classical machines such as the bicycle continue to use different handed threads on each side while other machines such as, bench grinders, circular saws and brush cutters still use left-handed threads to fasten rotating components. Despite the continued use of left-handed fasteners, the rationale and analysis of left-handed threads to mitigate self-loosening of fasteners in rotating applications is not commonly, if at all, discussed in the literature or design textbooks. Without scientific literature to support these design selections, these implementations may be the result of experimental findings or aged institutional knowledge. Based on a review of rotating applications, historical documents and mechanical design references, a formal study of the paradoxical nature of left-handed threads in various applications is merited.

The Effect of Press Fit on Osseointegration of Acetabular Cup

The primary cause of Total Hip Replacement (THR) failure for younger patients is aseptic loosening. This complication is twice more likely to happen in acetabular cup than in femoral stem. Excessive micromotion between bone and implant will cause loosening and it depends in patient activities, age and bone. In this project, the effects of different metal back design of press fit on osseointegration of the acetabular cup are carried out. Commercial acetabular cup designs, namely Spiked, Superfix and Quadrafix are modelled and analyzed using commercial finite element software. The diameter of acetabular cup is based on the diameter of acetabular rim to make sure the component fit to the acetabular cavity. A new design of acetabular cup are proposed and analyzed to get better osseointegration between the bones and implant interface. Results shows that the proposed acetabular cup designs are more stable compared to other designs with respect to stress and displacement aspects.