Abstract: Knee collateral ligaments play a significant role in restraining excessive frontal motion (varus/valgus rotations). In this investigation, a multiscale frame was developed based on structural hierarchies of the collateral ligaments starting from the bottom (tropocollagen molecule) to up where the fibred reinforced structure established. Experimental data of failure tensile test were considered as the principal driver of the developed model. This model was calibrated statistically using Bayesian calibration due to the high number of unknown parameters. Then the model is scaled up to fit the real structure of the collateral ligaments and simulated under realistic boundary conditions. Predications have been successful in describing the observed transient response of the collateral ligaments during tensile test under pre- and post-damage loading conditions. Collateral ligaments maximum stresses and strengths were observed near to the femoral insertions, a results that is in good agreement with experimental investigations. Also for the first time, damage initiation and propagation were documented with this model as a function of the cross-link density between tropocollagen molecules.
Abstract: The human middle ear (ME) is a delicate and vital organ. It has a complex structure that performs various functions such as receiving sound pressure and producing vibrations of eardrum and propagating it to inner ear. It consists of Tympanic Membrane (TM), three auditory ossicles, various ligament structures and muscles. Incidents such as traumata, infections, ossification of ossicular structures and other pathologies may damage the ME organs. The conditions can be surgically treated by employing prosthesis. However, the suitability of the prosthesis needs to be examined in advance prior to the surgery. Few decades ago, this issue was addressed and analyzed by developing an equivalent representation either in the form of spring mass system, electrical system using R-L-C circuit or developing an approximated CAD model. But, nowadays a three-dimensional ME model can be constructed using micro X-Ray Computed Tomography (μCT) scan data. Moreover, the concern about patient specific integrity pertaining to the disease can be examined well in advance. The current research work emphasizes to develop the ME model from the stacks of μCT images which are used as input file to MIMICS Research 19.0 (Materialise Interactive Medical Image Control System) software. A stack of CT images is converted into geometrical surface model to build accurate morphology of ME. The work is further extended to understand the dynamic behaviour of Harmonic response of the stapes footplate and umbo for different sound pressure levels applied at lateral side of eardrum using finite element approach. The pathological condition Cholesteatoma of ME is investigated to obtain peak to peak displacement of stapes footplate and umbo. Apart from this condition, other pathologies, mainly, changes in the stiffness of stapedial ligament, TM thickness and ossicular chain separation and fixation are also explored. The developed model of ME for pathologies is validated by comparing the results available in the literatures and also with the results of a normal ME to calculate the percentage loss in hearing capability.
Abstract: In this study, a new constitutive model is developed
to describe the hyperelastic behavior of collagenous tissues with a
parallel arrangement of collagen fibers such as ligaments and tendons.
The model is formulated using a continuum approach incorporating
the structural changes of the main tissue components: collagen fibers,
proteoglycan-rich matrix and fiber-matrix interaction. The mechanical
contribution of the interaction between the fibers and the matrix
is simply expressed by a coupling term. The structural change
of the collagen fibers is incorporated in the constitutive model to
describe the activation of the fibers under tissue straining. Finally, the
constitutive model can easily describe the stress-stretch nonlinearity
which occurs when a ligament/tendon is axially stretched. This
study shows that the interaction between the fibers and the matrix
contributes to the mechanical tissue response. Therefore, the model
may lead to a better understanding of the physiological mechanisms
of ligaments and tendons under axial loading.
Abstract: A novel hybrid model of the lumbar spine, allowing
fast static and dynamic simulations of the disc pressure
and the spine mobility, is introduced in this work. Our
contribution is to combine rigid bodies, deformable finite
elements, articular constraints, and springs into a unique model
of the spine. Each vertebra is represented by a rigid body
controlling a surface mesh to model contacts on the facet
joints and the spinous process. The discs are modeled using
a heterogeneous tetrahedral finite element model. The facet
joints are represented as elastic joints with six degrees of
freedom, while the ligaments are modeled using non-linear
one-dimensional elastic elements. The challenge we tackle
is to make these different models efficiently interact while
respecting the principles of Anatomy and Mechanics.
The mobility, the intradiscal pressure, the facet joint force and
the instantaneous center of rotation of the lumbar spine are
validated against the experimental and theoretical results of
the literature on flexion, extension, lateral bending as well as
axial rotation.
Our hybrid model greatly simplifies the modeling task and
dramatically accelerates the simulation of pressure within the
discs, as well as the evaluation of the range of motion and the
instantaneous centers of rotation, without penalizing precision.
These results suggest that for some types of biomechanical
simulations, simplified models allow far easier modeling and
faster simulations compared to usual full-FEM approaches
without any loss of accuracy.
Abstract: A group of 10 dogs (group A) with Periodontal Disease in the third stage, were subjected to regenerative therapy of periodontal tissues, by use of nano hydroxy apatite (NHA). These animals induced by general anesthesia, where treated by ultrasonic scaling, root planning, and at the end by a mucogingival flap in which it was applied NHA. The flap was closed and sutured with simple steps. Another group of 10 dogs (group B), control group, was treated only by scaling and root planning. No patient was subjected to antibiotic therapy. After three months, a check was made by inspection of the oral cavity, radiography and bone biopsy at the alveolar level. Group A showed a total restitutio ad integrum of the periodontal structures, and in group B still mild gingivitis in 70% of cases and 30% of the state remains unchanged. Numerous experimental studies both in animals and humans have documented that the grafts of porous hydroxyapatite are rapidly invaded by fibrovascular tissue which is subsequently converted into mature lamellar bone tissue by activating osteoblast. Since we acted on the removal of necrotic cementum and rehabilitating the root tissue by polishing without intervention in the ligament but only on anatomical functional interface of cement-blasts, we can connect the positive evolution of the clinical-only component of the cement that could represent this perspective, the only reason that Periodontal Disease become a Cement Disease, while all other clinical elements as nothing more than a clinical pathological accompanying.
Abstract: The human knee joint has a three dimensional
geometry with multiple body articulations that produce complex
mechanical responses under loads that occur in everyday life and
sports activities. To produce the necessary joint compliance and
stability for optimal daily function various menisci and ligaments are
present while muscle forces are used to this effect. Therefore,
knowledge of the complex mechanical interactions of these load
bearing structures is necessary when treatment of relevant diseases is
evaluated and assisting devices are designed.
Numerical tools such as finite element analysis are suitable for
modeling such joints in order to understand their physics. They have
been used in the current study to develop an accurate human knee
joint and model its mechanical behavior. To evaluate the efficacy of
this articulated model, static load cases were used for comparison
purposes with previous experimentally verified modeling works
drawn from literature.
Abstract: In this paper, the construction of a detailed spine
model is presented using the LifeMOD Biomechanics Modeler. The
detailed spine model is obtained by refining spine segments in
cervical, thoracic and lumbar regions into individual vertebra
segments, using bushing elements representing the intervertebral
discs, and building various ligamentous soft tissues between
vertebrae. In the sagittal plane of the spine, constant force will be
applied from the posterior to anterior during simulation to determine
dynamic characteristics of the spine. The force magnitude is
gradually increased in subsequent simulations. Based on these
recorded dynamic properties, graphs of displacement-force
relationships will be established in terms of polynomial functions by
using the least-squares method and imported into a haptic integrated
graphic environment. A thoracolumbar spine model with complex
geometry of vertebrae, which is digitized from a resin spine
prototype, will be utilized in this environment. By using the haptic
technique, surgeons can touch as well as apply forces to the spine
model through haptic devices to observe the locomotion of the spine
which is computed from the displacement-force relationship graphs.
This current study provides a preliminary picture of our ongoing
work towards building and simulating bio-fidelity scoliotic spine
models in a haptic integrated graphic environment whose dynamic
properties are obtained from LifeMOD. These models can be helpful
for surgeons to examine kinematic behaviors of scoliotic spines and
to propose possible surgical plans before spine correction operations.
Abstract: The objective of this study was to develop and compare alternative prediction equations of lean meat proportion (LMP) of lamb carcasses. Forty (40) male lambs, 22 of Churra Galega Bragançana Portuguese local breed and 18 of Suffolk breed were used. Lambs were slaughtered, and carcasses weighed approximately 30 min later in order to obtain hot carcass weight (HCW). After cooling at 4º C for 24-h a set of seventeen carcass measurements was recorded. The left side of carcasses was dissected into muscle, subcutaneous fat, inter-muscular fat, bone, and remainder (major blood vessels, ligaments, tendons, and thick connective tissue sheets associated with muscles), and the LMP was evaluated as the dissected muscle percentage. Prediction equations of LMP were developed, and fitting quality was evaluated through the coefficient of determination of estimation (R2 e) and standard error of estimate (SEE). Models validation was performed by k-fold crossvalidation and the coefficient of determination of prediction (R2 p) and standard error of prediction (SEP) were computed. The BT2 measurement was the best single predictor and accounted for 37.8% of the LMP variation with a SEP of 2.30%. The prediction of LMP of lamb carcasses can be based simple models, using as predictors the HCW and one fat thickness measurement.
Abstract: The purpose of this research is to compare the original
intra-oral digital dental radiograph images with images that are
enhanced using a combination of image processing algorithms. Intraoral
digital dental radiograph images are often noisy, blur edges and
low in contrast. A combination of sharpening and enhancement
method are used to overcome these problems. Three types of
proposed compound algorithms used are Sharp Adaptive Histogram
Equalization (SAHE), Sharp Median Adaptive Histogram
Equalization (SMAHE) and Sharp Contrast adaptive histogram
equalization (SCLAHE). This paper presents an initial study of the
perception of six dentists on the details of abnormal pathologies and
improvement of image quality in ten intra-oral radiographs. The
research focus on the detection of only three types of pathology
which is periapical radiolucency, widen periodontal ligament space
and loss of lamina dura. The overall result shows that SCLAHE-s
slightly improve the appearance of dental abnormalities- over the
original image and also outperform the other two proposed
compound algorithms.
Abstract: The scientific perspective, the practice area of physical education and sports activities improve power capacity in all its forms of expression, being a generator of the research topics. Today theories that strength training athletes and slow down development progress will affect the strength and flexibility are discredited. On the other hand there are sectors and / or samples whose results are sports of the way higher manifestation of power as a result of the composition of the force and velocity, being based in this respect on the systematic and continuous development of both bio-motric capacities said. Training of force for children was and is controversial. Teama de accidentări sau a stopării premature a procesului de creştere a făcut ca în trecut copiii să fie ţinuţi departe de lucrul cu diferite greutăţi.Fear of injury or premature stop the growth process in the past made the children to be kept away from working with different weights. Recent studies have shown that the risk of accidents is relatively small and the strength training can help prevent them. For example, most accidents occur at the level of athletics ligaments and tendons. From this point of view, it can be said that a progressive intervention of force training, optimal design, will help enhancing their process, such as athlete much better prepared to meet training requests and competitions. Preparation of force provides a solid basis for further phases in the highest performance.