Abstract: This paper deals with the harmonic decontamination of current in an electrical grid by an active shunt filter in order to improve power quality. The contribution of this paper is mainly based on the proposal of a control strategy for an active filter based on Duty Cycle Modulation (DCM). First, three-monophase method is applied for the identification of disturbing currents. A Simulink model of this method is given for one phase of the grid. Secondly, two orders were designed: the first one is the Hysteresis Control and the second one is the DCM Control. Finally, a comparative study of the two controls was performed. The results obtained show a significant improvement in the rate of harmonic distortion for both controls. The harmonic distortion for the Hysteresis control is limited by the non-controllability of the switching frequencies of the inverter's switches and reduces the harmonic distortion rate (THD) to 3.12% as opposed to the DCM control which limits the THD to 2.82% which makes it better.
Abstract: The present paper provides a detailed analysis of prior methods and approaches for non-linear load identification in residential buildings. The main goal of this analysis is to decipher the distorted signals and to estimate the harmonics influence on power systems. We have performed an analytical study of non-linear loads behavior in the residential environment. Simulations have been performed in order to evaluate the distorted rate of the current and follow his behavior. To complete this work, an instrumental platform has been realized to carry out practical tests on single-phase non-linear loads which illustrate the current consumption of some domestic appliances supplied with single-phase sinusoidal voltage. These non-linear loads have been processed and tracked in order to limit their influence on the power grid and to reduce the Joule effect losses. As a result, the study has allowed to identify responsible circuits of harmonic pollution.
Abstract: The selection of control strategy depends on the converters of the drive including power, speed, performance and the possible system costs. A number of attempts were therefore made in recent times to develop novel power electronic converter structures for SRM drives, based on the utilization. Many of the converters with variable speed drives have no input power factor correction circuits. This results in harmonic pollution of the utility supply, which should be avoided. The effect of power factor variation in terms of harmonic content is also analyzed in this study. The proposed topologies were simulated using MATLAB / Simulink software package and the results are obtained.
Abstract: Harmonic pollution and low power factor in power
systems caused by power converters have been of great concern. To
overcome these problems several converter topologies using
advanced semiconductor devices and control schemes have been
proposed. This investigation is to identify a low cost, small size,
efficient and reliable ac to dc converter to meet the input performance
index of UPS. The performance of single phase and three phase ac to
dc converter along with various control techniques are studied and
compared. The half bridge converter topology with linear current
control is identified as most suitable. It is simple, energy efficient
because of single switch power loss and transformer-less operation of
UPS. The results are validated practically using a prototype built
using IGBT and analog controller. The performance for both single
and three-phase system is verified. Digital implementation of closed
loop control achieves higher reliability. Its cost largely depends on
chosen bit precision. The minimal bit precision for optimum
converter performance is identified as 16-bit with fixed-point
operation. From the investigation and practical implementation it is
concluded that half bridge ac – dc converter along with digital linear
controller meets the performance index of UPS for single and three
phase systems.
Abstract: The presence of harmonic in power system is a major
concerned to power engineers for many years. With the increasing
usage of nonlinear loads in power systems, the harmonic pollution
becomes more serious. One of the widely used computation
algorithm for harmonic analysis is fast Fourier transform (FFT). In
this paper, a harmonic analyzer using FFT was implemented on
TMS320C6713 DSK. The supply voltage of 240 V 59 Hz is stepped
down to 5V using a voltage divider in order to match the power
rating of the DSK input. The output from the DSK was displayed on
oscilloscope and Code Composer Studio™ software. This work has
demonstrated the possibility of analyzing the 240V power supply
harmonic content using the DSK board.