Abstract: In the context of sustainable development and climate change, the adaptation of buildings to the climatic context in hot climates is a necessity if we want to improve living conditions in housing and reduce the risks to the health and productivity of occupants due to thermal discomfort in buildings. One can find a wide variety of efficient solutions but with high costs. In developing countries, especially tropical countries, we need to appreciate a technology with a very limited cost that is affordable for everyone, energy efficient and protects the environment. Biosourced insulation is a product based on plant fibers, animal products or products from recyclable paper or clothing. Their development meets the objectives of maintaining biodiversity, reducing waste and protecting the environment. In tropical or hot countries, the aim is to protect the building from solar thermal radiation, a source of discomfort. The aim of this work is in line with the logic of energy control and environmental protection, the approach is to make the occupants of buildings comfortable, reduce their carbon dioxide emissions (CO2) and decrease their energy consumption (energy efficiency). We have chosen to study the thermo-physical properties of banana leaves and sawdust, especially their thermal conductivities, direct measurements were made using the flash method and the hot plate method. We also measured the heat flow on both sides of each sample by the hot box method. The results from these different experiences show that these materials are very efficient used as insulation. We have also conducted a building thermal simulation using banana leaves as one of the materials under Design Builder software. Air-conditioning load as well as CO2 release was used as performance indicator. When the air-conditioned building cell is protected on the roof by banana leaves and integrated into the walls with solar protection of the glazing, it saves up to 64.3% of energy and avoids 57% of CO2 emissions.
Abstract: Multifamily residential buildings are increasingly being built with large glazed areas to provide tenants with greater daylight and outdoor views. However, traditional double-glazed window assemblies can lead to significant thermal discomfort from high radiant temperatures as well as increased cooling energy use to address solar gains. Dynamic glazing provides an effective solution by actively controlling solar transmission to maintain indoor thermal comfort, without compromising the visual connection to outdoors. This study uses thermal simulations across three Canadian cities (Toronto, Vancouver and Montreal) to verify if dynamic glazing along with operable windows and ceiling fans can maintain the indoor operative temperature of a prototype southwest facing high-rise apartment unit within the ASHRAE 55 adaptive comfort range for a majority of the year, without any mechanical cooling. Since this study proposes the use of natural ventilation for cooling and the typical building life cycle is 30-40 years, the typical weather files have been modified based on accepted global warming projections for increased air temperatures by 2050. Results for the prototype apartment confirm that thermal discomfort with dynamic glazing occurs only for less than 0.7% of the year. However, in the baseline scenario with low-E glass there are up to 7% annual hours of discomfort despite natural ventilation with operable windows and improved air movement with ceiling fans.
Abstract: Heat transfer through multiple pane windows can be reduced by creating a vacuum pressure less than 0.1 Pa between the glass panes, with low emittance coatings on one or more of the internal surfaces. Fabrication of vacuum glazing (VG) requires the formation of a hermetic seal around the periphery of the glass panes together with an array of support pillars between the panes to prevent them from touching under atmospheric pressure. Atmospheric pressure and temperature differentials induce stress which can affect the integrity of the glazing. Several parameters define the stresses in VG including the glass thickness, pillar specifications, glazing dimensions and edge seal configuration. Inherent stresses in VG can result in fractures in the glass panes and failure of the edge seal. In this study, stress in VG with different glass thicknesses is theoretically studied using Finite Element Modelling (FEM). Based on the finding in this study, suggestions are made to address problems resulting from the use of thinner glass panes in the fabrication of VG. This can lead to the development of high performance, light and thin VG.
Abstract: One of the most common and traditional strategies in architecture is to design buildings passively. This is a way to ensure low building energy reliance with respect to specific micro-building locations. There are so many ways where buildings can be designed passively, some of which are applying thermal insulation, thermal mass, courtyard and glazing to wall ratio. This research investigates the impact of each of these aspects with respect to the hot and dry climate of the capital of Riyadh. Thermal Analysis Simulation (TAS) will be utilized which is powered by Environmental Design Simulation Limited company (EDSL). It is considered as one of the most powerful tools to predict energy performance in buildings. There are three primary building designs and methods which are using courtyard, thermal mass and thermal insulation. The same building size and fabrication properties have been applied to all designs. Riyadh city which is the capital of the country was taken as a case study of the research. The research has taken into account various zone directions within the building as it has a large contribution to indoor energy and thermal performance. It is revealed that it is possible to achieve nearly zero carbon building in the hot and dry region in winter with minimum reliance on energy loads for building zones facing south, west and east. Moreover, using courtyard is more beneficial than applying construction materials into building envelope. Glazing to wall ratio is recommended to be 10% and not exceeding 30% in all directions in hot and arid regions.
Abstract: Vacuum glazing is an innovative transparent thermal insulator that has application in high performance window, especially in renewable energy. Different materials as well as sealing methods have been adopted to seal windows with different temperatures. The impact of temperatures on sealing layers has been found to have significant effects on the microstructure of the seal. This paper seeks to investigate the effects of sealing materials specifically glass powder and flux compound (borax) for vacuum glazing. The findings of the experiment conducted show that the sealing material was rigid with some leakage around the edge, and we found that this could be stopped by enhancing the uniformity of the seal within the periphery. Also, we found that due to the intense tensile stress from the oven surface temperature of the seal at 200 0C, a crack was observed at the side of the glass. Based on the above findings, this study concludes that a glass powder with a lower melting temperature of below 250 0C with the addition of an adhesive (borax flux) should be used for future vacuum seals.
Abstract: Replacing of complex solar concentrating unit, this paper designs a solar heat-concentrating medium-temperature steam-generating system. Solar radiation is collected by using a large solar collecting and heat concentrating plate and is converged to the metal evaporating pipe with high efficient heat transfer. In the meantime, the heat loss is reduced by employing a double-glazed cover and other heat insulating structures. Thus, a high temperature is reached in the metal evaporating pipe. The influences of the system's structure parameters on system performance are analyzed. The steam production rate and the steam production under different solar irradiance, solar collecting and heat concentrating plate area, solar collecting and heat concentrating plate temperature and heat loss are obtained. The results show that when solar irradiance is higher than 600 W/m2, the effective heat collecting area is 7.6 m2 and the double-glazing cover is adopted, the system heat loss amount is lower than the solar irradiance value. The stable steam is produced in the metal evaporating pipe at 100 ℃, 110 ℃, and 120 ℃, respectively. When the average solar irradiance is about 896 W/m2, and the steaming cumulative time is about 5 hours, the daily steam production of the system is about 6.174 kg. In a single day, the solar irradiance is larger at noon, thus the steam production rate is large at that time. Before 9:00 and after 16:00, the solar irradiance is smaller, and the steam production rate is almost 0.
Abstract: The development of vacuum glazing represents a significant advancement in the area of low heat loss glazing systems with the potential to substantially reduce building heating and cooling loads. Vacuum glazing consists of two or more glass panes hermetically sealed together around the edge with a vacuum gap between the panes. To avoid the glass panes from collapsing and touching each other under the influence of atmospheric pressure an array of support pillars is provided between the glass panes. A high level of thermal insulation is achieved by evacuating the spaces between the glass panes to a very low pressure which greatly reduces conduction and convection within the space; therefore heat transfer through this kind of glazing is significantly lower when compared with conventional insulating glazing. However, vacuum glazing is subject to inherent stresses due to atmospheric pressure and temperature differentials which can lead to fracture of the glass panes and failure of the edge seal. A flexible edge seal has been proposed to minimise the impact of these issues. In this paper, vacuum glazing system with rigid and flexible edge seals is theoretically studied and their advantages and disadvantages are discussed.
Abstract: It is architecturally accepted that building form and design is considered as one of the most important aspects in affecting indoor temperature. The total area of building plan might be identical, but the design will have a major influence on the total area of external walls. This will have a clear impact on the amount of heat exchange with outdoor. Moreover, it will affect the position and area of glazing system. This has not received enough consideration in research by the specialists, since most of the publications are highlighting the impact of building envelope in terms of physical heat transfer in buildings. This research will investigate the impact of orientation of various building forms in various climatic regions. It will be concluded that orientation and glazing to wall ratio were recognized to be the most effective variables despite the shape of the building. However, linear ad radial forms were found more appropriate shapes almost across the continent.
Abstract: Utilization of solar energy can be found in various domestic and industrial applications. The performance of any solar collector is largely affected by various parameters such as glazing, absorber plate, top covers, and heating pipes. Technology improvements have brought us another method for conversion of solar energy to direct electricity using solar photovoltaic system. Utilization and extraction of solar energy is the biggest problem in these conversion methods. This paper aims to overcome these problems and take the advantages of available energy from solar by maximizing the utilization through solar tracking system using a refrigerant as a working medium. The use of this tracking system can help increase the efficiency of conversion devices by maximum utilization of solar energy. The dual axis tracking system gives maximum energy output compared to single axis tracking system.
Abstract: A single-phase closed thermosyphon has been
fabricated and experimented to utilize solar energy for water heating.
The working fluid of the closed thermosyphon is heated at the flatplate
collector and the hot water goes to the water tank due to density
gradient caused by temperature differences. This experimental work
was done using insulated water tank and insulated connecting pipe
between the tank and the flat-plate collector. From the collected data,
performance parameters such as instantaneous collector efficiency
and heat removal factor are calculated. In this study, the effects of
glazing were also observed. The water temperature rise and the
maximum instantaneous efficiency obtained from this experiment
with glazing using insulated water tank and insulated connecting pipe
are 17°C in a period of 5 hours and 60% respectively. Whereas the
water temperature rise and the maximum instantaneous efficiency
obtained from this experiment with glazing using non-insulated water
tank and non-insulated connecting pipe are 14°C in a period of 5
hours and 39% respectively.
Abstract: This research focuses on the optimization of glazed
surfaces and the assessment of possible solar gains in industrial
buildings. Existing window rating methods for single windows were
evaluated and a new method for a simple analysis of energy gains and
losses by single windows was introduced. Furthermore extensive
transient building simulations were carried out to appraise the
performance of low cost polycarbonate multi-cell sheets in
interaction with typical buildings for industrial applications. Mainly
energy saving potential was determined by optimizing the orientation
and area of such glazing systems in dependency on their thermal
qualities. Moreover the impact on critical aspects such as summer
overheating and daylight illumination was considered to ensure the
user comfort and avoid additional energy demand for lighting or
cooling. Hereby the simulated heating demand could be reduced by
up to 1/3 compared to traditional architecture of industrial halls using
mainly skylights.
Abstract: Hospitals, everywhere, are considered heavy energy consumers. Hospital Intensive Care Unit spaces pose a special challenge, where design guidelines requires the provision of external windows for daylighting and external view. Window protection strategies could be employed to reduce energy loads without detriment effect on comfort or health care. This paper addresses the effectiveness of using various window strategies on the annual cooling, heating and lighting energy use of a typical Hospital Intensive Unit space. Series of experiments were performed using the EnergyPlus simulation software for a typical Intensive Care Unit (ICU) space in Cairo, located in the Egyptian desert. This study concluded that the use of shading systems is more effective in conserving energy in comparison with glazing of different types, in the Cairo ICUs. The highest energy savings in the West and South orientations were accomplished by external perforated solar screens, followed by overhangs positioned at a protection angle of 45°.
Abstract: The use of solar control film on windows as one of
solar passive strategies for building have becoming important and is
gaining recognition. Malaysia located close to equator is having
warm humid climate with long sunshine hours and abundant solar
radiation throughout the year. Hence, befitting solar control on
windows is absolutely necessary to capture the daylight whilst
moderating thermal impact and eliminating glare problems. This is
one of the energy efficient strategies to achieve thermal and visual
comfort in buildings. Therefore, this study was carried out to
investigate the effect of window solar controls on thermal and visual
performance of naturally ventilated buildings. This was conducted via
field data monitoring using a test building facility. Four types of
window glazing systems were used with three types of solar control
films. Data were analysed for thermal and visual impact with
reference to thermal and optical characteristics of the films. Results
show that for each glazing system, the surface temperature of
windows are influenced by the Solar Energy Absorption property, the
indoor air temperature are influenced by the Solar Energy
Transmittance and Solar Energy Reflectance, and the daylighting by
Visible Light Transmission and Shading Coefficient. Further
investigations are underway to determine the mathematical relation
between thermal energy and visual performance with the thermal and
optical characteristics of solar control films.
Abstract: Glazing is a process used to reduce undesirable drying or dehydration of fish during frozen or cold storage. To evaluate the effect of the time/ temperature binomial of the cryogenic frozen tunnel in the amount of glazing watera Central Composite Rotatable Design was used, with application of the Response Surface Methodology. The results reveal that the time/ temperature obtained for pink cusk-eel in experimental conditions for glazing water are similar to the industrial process, but for red fish and merluza the industrial process needs some adjustments. Control charts were established and implementedto control the amount of glazing water on sardine and merluza. They show that the freezing process was statistically controlled but there were some tendencies that must be analyzed, since the trend of sample mean values approached either of the limits, mainly in merluza. Thus, appropriate actions must be taken, in order to improve the process.
Abstract: The counter flow solar air heaters, with four
transverse fins and wire mesh layers are constructed and investigated
experimentally for thermal efficiency at a geographic location of
Cyprus in the city of Famagusta. The absorber plate is replaced by
sixteen steel wire mesh layers, 0.18 x 0.18cm in cross section
opening and a 0.02cm in diameter. The wire mesh layers arranged in
three groups, first and second include 6 layers, while the third include
4 layers. All layers fixed in the duct parallel to the glazing and each
group separated from the others by wood frame thickness of 0.5cm to
reduce the pressure drop. The transverse fins arranged in a way to
force the air to flow through the bed like eight letter path with flow
depth 3cm. The proposed design has increased the heat transfer rate,
but on other hand causes a high pressure drop. The obtained results
show that, for air mass flow rate range between 0.011-0.036kg/s, the
thermal efficiency increases with increasing the air mass flow. The
maximum efficiency obtained is 65.6% for the mass flow rate of
0.036kg/s. Moreover, the temperature difference between the outlet
flow and the ambient temperature, ΔT, reduces as the air mass flow
rate increase. The maximum difference between the outlet and
ambient temperature obtained was 43°C for double pass for minimum
mass flow rate of 0.011kg/s. Comparison with a conventional solar
air heater collector shows a significantly development in the thermal
efficiency.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.