Abstract: The smart antenna is the prominent technology that has become known in recent years to meet the growing demands of wireless communications. In an overcrowded atmosphere, its application is growing gradually. A methodical evaluation of the performance of Fixed Beamforming algorithms for smart antennas such as Multiple Sidelobe Canceller (MSC), Maximum Signal-to-interference ratio (MSIR) and minimum variance (MVDR) has been comprehensively presented in this paper. Simulation results show that beamforming is helpful in providing optimized response towards desired directions. MVDR beamformer provides the most optimal solution.
Abstract: This paper describes optimal thinning of an Elliptical
Cylindrical Array (ECA) of uniformly excited isotropic antennas
which can generate directive beam with minimum relative Side Lobe
Level (SLL). The Particle Swarm Optimization (PSO) method, which
represents a new approach for optimization problems in
electromagnetic, is used in the optimization process. The PSO is used
to determine the optimal set of ‘ON-OFF’ elements that provides a
radiation pattern with maximum SLL reduction. Optimization is done
without prefixing the value of First Null Beam Width (FNBW). The
variation of SLL with element spacing of thinned array is also
reported. Simulation results show that the number of array elements
can be reduced by more than 50% of the total number of elements in
the array with a simultaneous reduction in SLL to less than -27dB.
Abstract: The work describes the use of a synthetic transmit
aperture (STA) with a single element transmitting and all elements
receiving in medical ultrasound imaging. STA technique is a novel
approach to today-s commercial systems, where an image is acquired
sequentially one image line at a time that puts a strict limit on the
frame rate and the amount of data needed for high image quality. The
STA imaging allows to acquire data simultaneously from all
directions over a number of emissions, and the full image can be
reconstructed.
In experiments a 32-element linear transducer array with 0.48 mm
inter-element spacing was used. Single element transmission aperture
was used to generate a spherical wave covering the full image region.
The 2D ultrasound images of wire phantom are presented obtained
using the STA and commercial ultrasound scanner Antares to
demonstrate the benefits of the SA imaging.
Abstract: The paper presents the study of synthetic transmit
aperture method applying the Golay coded transmission for medical
ultrasound imaging. Longer coded excitation allows to increase the
total energy of the transmitted signal without increasing the peak
pressure. Signal-to-noise ratio and penetration depth are improved
maintaining high ultrasound image resolution.
In the work the 128-element linear transducer array with 0.3 mm
inter-element spacing excited by one cycle and the 8 and 16-bit
Golay coded sequences at nominal frequencies 4 MHz was used.
Single element transmission aperture was used to generate a spherical
wave covering the full image region and all the elements received the
echo signals. The comparison of 2D ultrasound images of the wire
phantom as well as of the tissue mimicking phantom is presented to
demonstrate the benefits of the coded transmission. The results were
obtained using the synthetic aperture algorithm with transmit and
receive signals correction based on a single element directivity
function.
Abstract: In the paper the study of synthetic transmit aperture
method applying the Golay coded transmission for medical
ultrasound imaging is presented. Longer coded excitation allows to
increase the total energy of the transmitted signal without increasing
the peak pressure. Moreover signal-to-noise ratio and penetration
depth are improved while maintaining high ultrasound image
resolution. In the work the 128-element linear transducer array with
0.3 mm inter-element spacing excited by one cycle and the 8 and 16-
bit Golay coded sequences at nominal frequency 4 MHz was used. To
generate a spherical wave covering the full image region a single
element transmission aperture was used and all the elements received
the echo signals. The comparison of 2D ultrasound images of the
tissue mimicking phantom and in vitro measurements of the beef liver
is presented to illustrate the benefits of the coded transmission. The
results were obtained using the synthetic aperture algorithm with
transmit and receive signals correction based on a single element
directivity function.