Abstract: Collapsible soils like loess comprise an important category of problematic soils for construction purposes and sustainable development. As a result, research on both geological and geotechnical aspects of this type of soil have been in progress for decades. However, considerable natural variability in physical properties of in-situ loess strata even in a single block sample challenges the fundamental laboratory investigations. The reason behind this is that it is somehow impossible to remove the effect of a specific factor like void ratio from fair comparisons to come with a reliable conclusion. In order to cope with this limitation, two types of artificially made dispersive and calcareous loess are introduced which can be easily reproduced in any soil mechanics laboratory provided that all its compositions are known and controlled. The collapse potential is explored for a variety of soil water salinity and lime content and comparisons are made against the natural soil behavior. Trends are reported for the influence of pore water salinity on collapse potential under different osmotic flow conditions. The most important advantage of artificial loess is the ease of controlling cementing agent content like calcite or dispersive potential for studying their influence on mechanical soil behavior.
Abstract: Predicting the collapse potential of a structure during
earthquakes is an important issue in earthquake engineering. Many
researchers proposed different methods to assess the collapse
potential of structures under the effect of strong ground motions.
However most of them did not consider degradation and softening
effect in hysteretic behavior. In this study, collapse potential of
SDOF systems caused by dynamic instability with stiffness and
strength degradation has been investigated. An equation was
proposed for the estimation of collapse period of SDOF system which
is a limit value of period for dynamic instability. If period of the
considered SDOF system is shorter than the collapse period then the
relevant system exhibits dynamic instability and collapse occurs.
Abstract: Collapsible soils go through radical rearrangement of
their particles when triggered by water, stress or/and vibration,
causing loss of volume. This loss of volume in soil as seen in
foundation failures has caused millions of dollars’ worth of damages
to public facilities and infrastructure and so has an adverse effect on
the society and people. Despite these consequences and the several
studies that are available, more research is still required in the study
of soil collapsibility. Discerning the pedogenesis (formation) of soils
and investigating the combined effects of the different geological soil
properties is key to elucidating and quantifying soils collapsibility.
This study presents a novel laboratory testing regime that would be
undertaken on soil samples where the effects of soil type, compactive
variables (moisture content, density, void ratio, degree of saturation)
and loading are analyzed. It is anticipated that results obtained would
be useful in mapping the trend of the combined effect thus the basis
for evaluating soil collapsibility or collapse potentials encountered in
construction with volume loss problems attributed to collapse.
Abstract: Interior brick-infill partitions are usually considered as
non-structural components, and only their weight is accounted for in
practical structural design. In this study, the brick-infill panels are
simulated by compression struts to clarify their effect on the
progressive collapse potential of an earthquake-resistant RC building.
Three-dimensional finite element models are constructed for the RC
building subjected to sudden column loss. Linear static analyses are
conducted to investigate the variation of demand-to-capacity ratio
(DCR) of beam-end moment and the axial force variation of the beams
adjacent to the removed column. Study results indicate that the
brick-infill effect depends on their location with respect to the
removed column. As they are filled in a structural bay with a shorter
span adjacent to the column-removed line, more significant reduction
of DCR may be achieved. However, under certain conditions, the
brick infill may increase the axial tension of the two-span beam
bridging the removed column.