Abstract: Dynamics of cathode spot has become a major part
of vacuum arc discharge with its high academic interest and
wide application potential. In this article, using a three-dimensional
statistical model, we simulate the distribution of the ignition
probability of a new cathode spot occurring in different magnetic
pressure on old cathode spot surface and at different arcing time.
This model for the ignition probability of a new cathode spot was
proposed in two typical situations, one by the pure isotropic random
walk in the absence of an external magnetic field, other by the
retrograde motion in external magnetic field, in parallel with the
cathode surface. We mainly focus on developed relationship between
the ignition probability density distribution of a new cathode spot and
the external magnetic field.
Abstract: The purpose of this research was to analyze and compare the instability of a contact surface between Copper and Nickel an alloy cathode in vacuum, the different ratio of Copper and Copper were conducted at 1%, 2% and 4% by using the cathode spot model. The transient recovery voltage is predicted. The cathode spot region is recognized as the collisionless space charge sheath connected with singly ionized collisional plasma. It was found that the transient voltage is decreased with increasing the percentage of an amount of Nickel in cathode materials.
Abstract: A series of Ti based shape memory alloys with
composition of Ti50Ni49Cr1, Ti50Ni47Cr3 and Ti50Ni45Cr5 were
developed by vacuum arc-melting under a purified argon atmosphere.
The histometric and corrosion evaluation of Ti-Ni-Cr shape memory
alloys have been considered in this research work. The alloys were
developed by vacuum arc melting and implanted subcutaneously in
rabbits for 4, 8 and 12 weeks. Metallic implants were embedded in
order to determine the outcome of implantation on histometric and
corrosion evaluation of Ti-Ni-Cr metallic strips. Encapsulating
membrane formation around the alloys was minimal in the case of all
materials. After histomorphometric analyses it was possible to
demonstrate that there were no statistically significant differences
between the materials. Corrosion rate was also determined in this
study which is within acceptable range. The results showed the Ti-
Ni-Cr alloy was neither cytotoxic, nor have any systemic reaction on
living system in any of the test performed. Implantation shows good
compatibility and a potential of being used directly in vivo system.
Abstract: Vickers indentation is used to measure the hardness
of materials. In this study, numerical simulation of Vickers
indentation experiment was performed for Diamond like Carbon
(DLC) coated materials. DLC coatings were deposited on stainless
steel 304 substrates with Chromium buffer layer using RF Magnetron
and T-shape Filtered Cathodic Vacuum Arc Dual system The
objective of this research is to understand the elastic plastic
properties, stress strain distribution, ring and lateral crack growth and
propagation, penetration depth of indenter and delamination of
coating from substrate with effect of buffer layer thickness. The
effect of Poisson-s ratio of DLC coating was also analyzed. Indenter
penetration is more in coated materials with thin buffer layer as
compared to thicker one, under same conditions. Similarly, the
specimens with thinner buffer layer failed quickly due to high
residual stress as compared to the coated materials with reasonable
thickness of 200nm buffer layer. The simulation results suggested the
optimized thickness of 200 nm among the prepared specimens for
durable and long service.