Abstract: In this work, the laser ultrasound technique has been used for analyzing and imaging the inner defects in metal blocks. To detect the defects in blocks, traditionally the researchers used piezoelectric transducers for the generation and reception of ultrasonic signals. These transducers can be configured into the sparse and phased array. But these two configurations have their drawbacks including the requirement of many transducers, time-consuming calculations, limited bandwidth, and provide confined image resolution. Here, we focus on the non-contact method for generating and receiving the ultrasound to examine the inner defects in aluminum blocks. A Q-switched pulsed laser has been used for the generation and the reception is done by using Laser Doppler Vibrometer (LDV). Based on the Doppler effect, LDV provides a rapid and high spatial resolution way for sensing ultrasonic waves. From the LDV, a series of scanning points are selected which serves as the phased array elements. The side-drilled hole of 10 mm diameter with a depth of 25 mm has been introduced and the defect is interrogated by the linear array of scanning points obtained from the LDV. With the aid of the Synthetic Aperture Focusing Technique (SAFT) algorithm, based on the time-shifting principle the inspected images are generated from the A-scan data acquired from the 1-D linear phased array elements. Thus the defect can be precisely detected with good resolution.
Abstract: The work describes the use of a synthetic transmit
aperture (STA) with a single element transmitting and all elements
receiving in medical ultrasound imaging. STA technique is a novel
approach to today-s commercial systems, where an image is acquired
sequentially one image line at a time that puts a strict limit on the
frame rate and the amount of data needed for high image quality. The
STA imaging allows to acquire data simultaneously from all
directions over a number of emissions, and the full image can be
reconstructed.
In experiments a 32-element linear transducer array with 0.48 mm
inter-element spacing was used. Single element transmission aperture
was used to generate a spherical wave covering the full image region.
The 2D ultrasound images of wire phantom are presented obtained
using the STA and commercial ultrasound scanner Antares to
demonstrate the benefits of the SA imaging.
Abstract: We have previously introduced an ultrasonic imaging
approach that combines harmonic-sensitive pulse sequences with a
post-beamforming quadratic kernel derived from a second-order
Volterra filter (SOVF). This approach is designed to produce images
with high sensitivity to nonlinear oscillations from microbubble
ultrasound contrast agents (UCA) while maintaining high levels of
noise rejection. In this paper, a two-step algorithm for computing the
coefficients of the quadratic kernel leading to reduction of tissue
component introduced by motion, maximizing the noise rejection and
increases the specificity while optimizing the sensitivity to the UCA
is presented. In the first step, quadratic kernels from individual
singular modes of the PI data matrix are compared in terms of their
ability of maximize the contrast to tissue ratio (CTR). In the second
step, quadratic kernels resulting in the highest CTR values are
convolved. The imaging results indicate that a signal processing
approach to this clinical challenge is feasible.