Abstract: In this paper, Integral Proportional (I-P) controller is employed for superheated steam temperature control system. The Ziegler-Nichols (Z-N) method is used for the tuning of I-P controller. The performance analysis of Z-N based I-P controller is assessed on superheated steam system of 500-MW boiler. The comparison of transient response parameters such as rise time, settling time, and overshoot is made with Z-N based Proportional Integral (PI) controller. It is observed from the results that Z-N based I-P controller completely eliminates the overshoot in the output response.
Abstract: Nowadays, desalination of salt water is considered an important industrial process. In many parts of the world, particularly in the gulf countries, the multi-stage flash (MSF) water desalination has an essential contribution in the production of fresh water. In this study, a simple mathematical model is defined to design a MSF desalination system and the feasibility of using the MSF desalination process in proximity of a 42 MW power plant is investigated. This power plant can just provide 10 ton/h superheated steam from low pressure (LP) section of heat recovery steam generator (HRSG) for thermal desalting system. The designed MSF system with gained output ratio (GOR) of 10.3 has 24 flashing stages and can produce 2480 ton/d of fresh water. The expected performance characteristics of the designed MSF desalination plant are determined. In addition, the effect of motive water pressure on the amount of non-condensable gases removed by water jet vacuum pumps is investigated.
Abstract: The remediation of water resources pollution in
developing countries requires the application of alternative
sustainable cheaper and efficient end-of-pipe wastewater treatment
technologies. The feasibility of use of South African cheap and
abundant pine tree (Pinus patula) sawdust for development of lowcost
AC of comparable quality to expensive commercial ACs in the
abatement of water pollution was investigated. AC was developed at
optimized two-stage N2-superheated steam activation conditions in a
fixed bed reactor, and characterized for proximate and ultimate
properties, N2-BET surface area, pore size distribution, SEM, pHPZC
and FTIR. The sawdust pyrolysis activation energy was evaluated by
TGA. Results indicated that the chars prepared at 800oC and 2hrs
were suitable for development of better quality AC at 800oC and 47%
burn-off having BET surface area (1086m2/g), micropore volume
(0.26cm3/g), and mesopore volume (0.43cm3/g) comparable to
expensive commercial ACs, and suitable for water contaminants
removal. The developed AC showed basic surface functionality at
pHPZC at 10.3, and a phenol adsorption capacity that was higher than
that of commercial Norit (RO 0.8) AC. Thus, it is feasible to develop
better quality low-cost AC from (Pinus patula) sawdust using twostage
N2-steam activation in fixed-bed reactor.