Abstract: In order to improve the animal protein recommended daily intake of Nigerians, there is an upsurge in breeding of hitherto shunned food animals one of which is the rabbit. Radiography and ultrasonography are tools for diagnosing disease and evaluating the anatomical architecture of parts of the body non-invasively. As the rabbit is becoming a more important food animal, to achieve improved breeding of these animals, the best of the species form a breeding stock and will usually depend on breeding soundness which may be evaluated by assessment of the male reproductive organs by these tools. Four male intact rabbits weighing between 1.2 to 1.5 kg were acquired and acclimatized for 2 weeks. Dorsoventral views of the testes were acquired using a digital radiographic machine and a 5 MHz portable ultrasound scanner was used to acquire images of the testes in longitudinal, sagittal and transverse planes. Radiographic images acquired revealed soft tissue images of the testes in all rabbits. The testes lie in individual scrotal sacs sides on both sides of the midline at the level of the caudal vertebrae and thus are superimposed by caudal vertebrae and the caudal limits of the pelvic girdle. The ultrasonographic images revealed mostly homogenously hypoechogenic testes and a hyperechogenic mediastinum testis. The dorsal and ventral poles of the testes were heterogeneously hypoechogenic and correspond to the epididymis and spermatic cord. The rabbit is unique in the ability to retract the testes particularly when stressed and so careful and stressless handling during the procedures is of paramount importance. The imaging of rabbit testes can be safely done using both imaging methods but ultrasonography is a better method of assessment and evaluation of soundness for breeding.
Abstract: Anti-scatter grids used in radiographic imaging for the contrast enhancement leave specific artifacts. Those artifacts may be visible or may cause Moiré effect when digital image is resized on a diagnostic monitor. In this paper we propose an automated grid artifactsdetection and suppression algorithm which is still an actual problem. Grid artifacts detection is based on statistical approach in spatial domain. Grid artifacts suppression is based on Kaiser bandstop filter transfer function design and application avoiding ringing artifacts. Experimental results are discussed and concluded with description of advantages over existing approaches.
Abstract: In non destructive testing by radiography, a perfect
knowledge of the weld defect shape is an essential step to
appreciate the quality of the weld and make decision on its
acceptability or rejection. Because of the complex nature of the
considered images, and in order that the detected defect region
represents the most accurately possible the real defect, the choice
of thresholding methods must be done judiciously. In this paper,
performance criteria are used to conduct a comparative study of
four non parametric histogram thresholding methods for automatic
extraction of weld defect in radiographic images.
Abstract: With the advance of multimedia and diagnostic
images technologies, the number of radiographic images is increasing
constantly. The medical field demands sophisticated systems for
search and retrieval of the produced multimedia document. This
paper presents an ongoing research that focuses on the semantic
content of radiographic image documents to facilitate semantic-based
radiographic image indexing and a retrieval system. The proposed
model would divide a radiographic image document, based on its
semantic content, and would be converted into a logical structure or
a semantic structure. The logical structure represents the overall
organization of information. The semantic structure, which is bound
to logical structure, is composed of semantic objects with
interrelationships in the various spaces in the radiographic image.
Abstract: In non destructive testing by radiography, a perfect knowledge of the weld defect shape is an essential step to appreciate the quality of the weld and make decision on its acceptability or rejection. Because of the complex nature of the considered images, and in order that the detected defect region represents the most accurately possible the real defect, the choice of thresholding methods must be done judiciously. In this paper, performance criteria are used to conduct a comparative study of thresholding methods based on gray level histogram, 2-D histogram and locally adaptive approach for weld defect extraction in radiographic images.
Abstract: This paper is devoted to present and discuss a model that allows a local segmentation by using statistical information of a given image. It is based on Chan-Vese model, curve evolution, partial differential equations and binary level sets method. The proposed model uses the piecewise constant approximation of Chan-Vese model to compute Signed Pressure Force (SPF) function, this one attracts the curve to the true object(s)-s boundaries. The implemented model is used to extract weld defects from weld radiographic images in the aim to calculate the perimeter and surfaces of those weld defects; encouraged resultants are obtained on synthetic and real radiographic images.
Abstract: A typical definition of the Computer Aided Diagnosis
(CAD), found in literature, can be: A diagnosis made by a radiologist
using the output of a computerized scheme for automated image
analysis as a diagnostic aid. Often it is possible to find the expression
Computer Aided Detection (CAD or CADe): this definition
emphasizes the intent of CAD to support rather than substitute the
human observer in the analysis of radiographic images. In this article
we will illustrate the application of CAD systems and the aim of
these definitions.
Commercially available CAD systems use computerized
algorithms for identifying suspicious regions of interest. In this paper
are described the general CAD systems as an expert system
constituted of the following components: segmentation / detection,
feature extraction, and classification / decision making.
As example, in this work is shown the realization of a Computer-
Aided Detection system that is able to assist the radiologist in
identifying types of mammary tumor lesions. Furthermore this
prototype of station uses a GRID configuration to work on a large
distributed database of digitized mammographic images.
Abstract: Industrial radiography is a famous technique for the identification and evaluation of discontinuities, or defects, such as cracks, porosity and foreign inclusions found in welded joints. Although this technique has been well developed, improving both the inspection process and operating time, it does suffer from several drawbacks. The poor quality of radiographic images is due to the physical nature of radiography as well as small size of the defects and their poor orientation relatively to the size and thickness of the evaluated parts. Digital image processing techniques allow the interpretation of the image to be automated, avoiding the presence of human operators making the inspection system more reliable, reproducible and faster. This paper describes our attempt to develop and implement digital image processing algorithms for the purpose of automatic defect detection in radiographic images. Because of the complex nature of the considered images, and in order that the detected defect region represents the most accurately possible the real defect, the choice of global and local preprocessing and segmentation methods must be appropriated.