Abstract: In this paper, an approach combining analytical method for the distributed generator (DG) sizing and meta-heuristic search for the optimal location of DG has been presented. The optimal size of DG on each bus is estimated by the loss sensitivity factor method while the optimal sites are determined by Particle Swarm Optimization (PSO) based optimal reactive power dispatch for minimizing active power loss. To confirm the proposed approach, it has been tested on IEEE-30 bus test system. The adjustments of operating constraints and voltage profile improvements have also been observed. The obtained results show that the allocation of DGs results in a significant loss reduction with good voltage profiles and the combined approach is competent in keeping the system voltages within the acceptable limits.
Abstract: The three phase system drives produce the problem of more torque pulsations and harmonics. This issue prevents the smooth operation of the drives and it also induces the amount of heat generated thus resulting in an increase in power loss. Higher phase system offers smooth operation of the machines with greater power capacity. Five phase variable-speed induction motor drives are commonly used in various industrial and commercial applications like tractions, electrical vehicles, ship propulsions and conveyor belt drive system. In this work, a comparative analysis of the different modulation schemes applied on the five-level five-phase Packed U Cell (PUC) inverter fed induction motor drives is presented. The performance of the inverter is greatly affected with the modulation schemes applied. The system is modeled, designed, and implemented in MATLABĀ®/Simulink environment. Experimental validation is done for the prototype of single phase, whereas five phase experimental validation is proposed in the future works.
Abstract: Smart grid is a new approach for electric power grid that uses information and communications technology to control the electric power grid. Smart grid provides real-time control of the electric power grid, controlling the direction of power flow or time of the flow. Control devices are installed on the power lines of the electric power grid to implement smart grid. The number of the control devices should be determined, in relation with the area one control device covers and the cost associated with the control devices. One approach to determine the number of the control devices is to use the data on the surplus power generated by home solar generators. In current implementations, the surplus power is sent all the way to the power plant, which may cause power loss. To reduce the power loss, the surplus power may be sent to a control device and sent to where the power is needed from the control device. Under assumption that the control devices are installed on a lattice of equal size squares, our goal is to figure out the optimal spacing between the control devices, where the power sharing area (the area covered by one control device) is kept small to avoid power loss, and at the same time the power sharing area is big enough to have no surplus power wasted. To achieve this goal, a simulation using landscape ecology method is conducted on a sample area. First an aerial photograph of the land of interest is turned into a mosaic map where each area is colored according to the ratio of the amount of power production to the amount of power consumption in the area. The amount of power consumption is estimated according to the characteristics of the buildings in the area. The power production is calculated by the sum of the area of the roofs shown in the aerial photograph and assuming that solar panels are installed on all the roofs. The mosaic map is colored in three colors, each color representing producer, consumer, and neither. We started with a mosaic map with 100 m grid size, and the grid size is grown until there is no red grid. One control device is installed on each grid, so that the grid is the area which the control device covers. As the result of this simulation we got 350m as the optimal spacing between the control devices that makes effective use of the surplus power for the sample area.
Abstract: Continuously variable transmission (CVT) is a type of
automatic transmission that can change the gear ratio to any arbitrary
setting within the limits. The most common type of CVT operates on
a pulley system that allows an infinite variability between highest and
lowest gears with no discrete steps. However, the current CVT
system with hydraulic actuation method suffers from the power loss.
It needs continuous force for the pulley to clamp the belt and hold the
torque resulting in large amount of energy consumption. This study
focused on the development of an electromechanical actuated control
CVT to eliminate the problem that faced by the existing CVT. It is
conducted with several steps; computing and selecting the
appropriate sizing for stroke length, lead screw system and etc. From
the visual observation it was found that the CVT system of this
research is satisfactory.
Abstract: This paper addresses a novel technique for placement of distributed generation (DG) in electric power systems. A GA based approach for sizing and placement of DG keeping in view of system power loss minimization in different loading conditions is explained. Minimal system power loss is obtained under voltage and line loading constraints. Proposed strategy is applied to power distribution systems and its effectiveness is verified through simulation results on 16, 37-bus and 75-bus test systems.
Abstract: This paper presents a new and efficient approach for
capacitor placement in radial distribution systems that determine
the optimal locations and size of capacitor with an objective of
improving the voltage profile and reduction of power loss. The
solution methodology has two parts: in part one the loss sensitivity
factors are used to select the candidate locations for the capacitor
placement and in part two a new algorithm that employs Plant growth
Simulation Algorithm (PGSA) is used to estimate the optimal size
of capacitors at the optimal buses determined in part one. The main
advantage of the proposed method is that it does not require any
external control parameters. The other advantage is that it handles the
objective function and the constraints separately, avoiding the trouble
to determine the barrier factors. The proposed method is applied to 9
and 34 bus radial distribution systems. The solutions obtained by the
proposed method are compared with other methods. The proposed
method has outperformed the other methods in terms of the quality
of solution.
Abstract: This paper presents a new and efficient approach for capacitor placement in radial distribution systems that determine the optimal locations and size of capacitor with an objective of improving the voltage profile and reduction of power loss. The solution methodology has two parts: in part one the loss sensitivity factors are used to select the candidate locations for the capacitor placement and in part two a new algorithm that employs Plant growth Simulation Algorithm (PGSA) is used to estimate the optimal size of capacitors at the optimal buses determined in part one. The main advantage of the proposed method is that it does not require any external control parameters. The other advantage is that it handles the objective function and the constraints separately, avoiding the trouble to determine the barrier factors. The proposed method is applied to 9, 34, and 85-bus radial distribution systems. The solutions obtained by the proposed method are compared with other methods. The proposed method has outperformed the other methods in terms of the quality of solution.
Abstract: This paper presents a new method which applies an
artificial bee colony algorithm (ABC) for capacitor placement in
distribution systems with an objective of improving the voltage profile
and reduction of power loss. The ABC algorithm is a new population
based meta heuristic approach inspired by intelligent foraging behavior
of honeybee swarm. The advantage of ABC algorithm is that
it does not require external parameters such as cross over rate and
mutation rate as in case of genetic algorithm and differential evolution
and it is hard to determine these parameters in prior. The other
advantage is that the global search ability in the algorithm is implemented
by introducing neighborhood source production mechanism
which is a similar to mutation process. To demonstrate the validity
of the proposed algorithm, computer simulations are carried out on
69-bus system and compared the results with the other approach
available in the literature. The proposed method has outperformed the
other methods in terms of the quality of solution and computational
efficiency.
Abstract: This paper describes the design of a voltage based maximum power point tracker (MPPT) for photovoltaic (PV) applications. Of the various MPPT methods, the voltage based method is considered to be the simplest and cost effective. The major disadvantage of this method is that the PV array is disconnected from the load for the sampling of its open circuit voltage, which inevitably results in power loss. Another disadvantage, in case of rapid irradiance variation, is that if the duration between two successive samplings, called the sampling period, is too long there is a considerable loss. This is because the output voltage of the PV array follows the unchanged reference during one sampling period. Once a maximum power point (MPP) is tracked and a change in irradiation occurs between two successive samplings, then the new MPP is not tracked until the next sampling of the PV array voltage. This paper proposes an MPPT circuit in which the sampling interval of the PV array voltage, and the sampling period have been shortened. The sample and hold circuit has also been simplified. The proposed circuit does not utilize a microcontroller or a digital signal processor and is thus suitable for low cost and low power applications.
Abstract: Optimal reactive power flow is an optimization problem
with one or more objective of minimizing the active power losses for
fixed generation schedule. The control variables are generator bus
voltages, transformer tap settings and reactive power output of the
compensating devices placed on different bus bars. Biogeography-
Based Optimization (BBO) technique has been applied to solve
different kinds of optimal reactive power flow problems subject
to operational constraints like power balance constraint, line flow
and bus voltages limits etc. BBO searches for the global optimum
mainly through two steps: Migration and Mutation. In the present
work, BBO has been applied to solve the optimal reactive power
flow problems on IEEE 30-bus and standard IEEE 57-bus power
systems for minimization of active power loss. The superiority of the
proposed method has been demonstrated. Considering the quality of
the solution obtained, the proposed method seems to be a promising
one for solving these problems.