Abstract: The assessment of psychomotor development allows us to identify children with motor delays, helps us to monitor progress in time and prepare suitable intervention programs. The foundation of psychomotor development lies in pre-school age and is crucial for child´s further cognitive and social development. Many assessment tools of psychomotor development have been developed over the years. Some of them are easy screening tools; others are more complex and sophisticated. The purpose of this review is to describe the history of psychomotor assessment, specify preschool children´s psychomotor evaluation and review eight psychomotor development assessment tools for preschool children (Denver II., DEMOST-PRE, TGMD -2/3, BOT-2, MABC-2, PDMS-2, KTK, MOT 4-6). The selection of test depends on purpose and context in which is the assessment planned.
Abstract: Micro-mixers play an important role in the lab-on-a-chip applications and micro total analysis systems to acquire the correct level of mixing for any given process. The mixing process can be classified as active or passive according to the use of external energy. Literature of microfluidics reports that most of the work is done on the models of steady laminar flow; however, the study of unsteady laminar flow is an active area of research at present. There are wide applications of this, out of which, we consider nanoparticle synthesis in micro-mixers. In this work, we have developed a model for unsteady flow to study the mixing performance of a passive micro mixer for reactants used for such synthesis. The model is developed in Finite Volume Method (FVM)-based software, OpenFOAM. The model is tested by carrying out the simulations at Re of 0.5. Mixing performance of the micro-mixer is investigated using simulated concentration values of mixed species across the width of the micro-mixer and calculating the variance across a line profile. Experimental validation is done by passing dyes through a Y shape micro-mixer fabricated using polydimethylsiloxane (PDMS) polymer and comparing variances with the simulated ones. Gold nanoparticles are later synthesized through the micro-mixer and collected at two different times leading to significantly different size distributions. These times match with the time scales over which reactant concentrations vary as obtained from simulations. Our simulations could thus be used to create design aids for passive micro-mixers used in nanoparticle synthesis.
Abstract: A bio-sensing method, based on the plasmonic property of gold nano-islands, has been developed for detection of exosomes in a clinical setting. The position of the gold plasmon band in the UV-Visible spectrum depends on the size and shape of gold nanoparticles as well as on the surrounding environment. By adsorbing various chemical entities, or binding them, the gold plasmon band will shift toward longer wavelengths and the shift is proportional to the concentration. Exosomes transport cargoes of molecules and genetic materials to proximal and distal cells. Presently, the standard method for their isolation and quantification from body fluids is by ultracentrifugation, not a practical method to be implemented in a clinical setting. Thus, a versatile and cutting-edge platform is required to selectively detect and isolate exosomes for further analysis at clinical level. The new sensing protocol, instead of antibodies, makes use of a specially synthesized polypeptide (Vn96), to capture and quantify the exosomes from different media, by binding the heat shock proteins from exosomes. The protocol has been established and optimized by using a glass substrate, in order to facilitate the next stage, namely the transfer of the protocol to a microfluidic environment. After each step of the protocol, the UV-Vis spectrum was recorded and the position of gold Localized Surface Plasmon Resonance (LSPR) band was measured. The sensing process was modelled, taking into account the characteristics of the nano-island structure, prepared by thermal convection and annealing. The optimal molar ratios of the most important chemical entities, involved in the detection of exosomes were calculated as well. Indeed, it was found that the results of the sensing process depend on the two major steps: the molar ratios of streptavidin to biotin-PEG-Vn96 and, the final step, the capture of exosomes by the biotin-PEG-Vn96 complex. The microfluidic device designed for sensing of exosomes consists of a glass substrate, sealed by a PDMS layer that contains the channel and a collecting chamber. In the device, the solutions of linker, cross-linker, etc., are pumped over the gold nano-islands and an Ocean Optics spectrometer is used to measure the position of the Au plasmon band at each step of the sensing. The experiments have shown that the shift of the Au LSPR band is proportional to the concentration of exosomes and, thereby, exosomes can be accurately quantified. An important advantage of the method is the ability to discriminate between exosomes having different origins.
Abstract: This paper presents the design and fabrication of a
novel piezoelectric actuator for a gas micro pump with check valve
having the advantages of miniature size, light weight and low power
consumption. The micro pump is designed to have eight major
components, namely a stainless steel upper cover layer, a piezoelectric
actuator, a stainless steel diaphragm, a PDMS chamber layer, two
stainless steel channel layers with two valve seats, a PDMS check
valve layer with two cantilever-type check valves and an acrylic
substrate. A prototype of the gas micro pump, with a size of 52 mm ×
50 mm × 5.0 mm, is fabricated by precise manufacturing. This device
is designed to pump gases with the capability of performing the
self-priming and bubble-tolerant work mode by maximizing the stroke
volume of the membrane as well as the compression ratio via
minimization of the dead volume of the micro pump chamber and
channel. By experiment apparatus setup, we can get the real-time
values of the flow rate of micro pump and the displacement of the
piezoelectric actuator, simultaneously. The gas micro pump obtained
higher output performance under the sinusoidal waveform of 250 Vpp.
The micro pump achieved the maximum pumping rates of 1185
ml/min and back pressure of 7.14 kPa at the corresponding frequency
of 120 and 50 Hz.
Abstract: Endothelium proliferation is an important process in cardiovascular homeostasis and can be regulated by extracellular environment, as cells can actively sense mechanical environment. In this study, we evaluated endothelial cell proliferation on PDMS/alumina (Al2O3) composites and pure PDMS. The substrates were prepared from pure PDMS and its composites with 5% and 10% Al2O3 at curing temperature 50˚C for 4h and then characterized by mechanical, structural and morphological analyses. Higher stiffness was found in the composites compared to the pure PDMS substrate. Cell proliferation of the cultured bovine aortic endothelial cells on substrate materials were evaluated via Resazurin assay and 1, 1’-Dioctadecyl-1, 3, 3, 3’, 3’-Tetramethylindocarbocyanine Perchlorate-Acetylated LDL (Dil-Ac-LDL) cell staining, respectively. The results revealed that stiffer substrates promote more endothelial cells proliferation to the less stiff substrates. Therefore, this study firmly hypothesizes that the stiffness elevates endothelial cells proliferation.
Abstract: Group contribution methods such as the UNIFAC are
very useful to researchers and engineers involved in synthesis,
feasibility studies, design and optimization of separation processes.
They can be applied successfully to predict phase equilibrium and
excess properties in the development of chemical and separation
processes. The main focus of this work was to investigate the
possibility of absorbing selected volatile organic compounds (VOCs)
into polydimethylsiloxane (PDMS) using three selected UNIFAC
group contribution methods. Absorption followed by subsequent
stripping is the predominant available abatement technology of
VOCs from flue gases prior to their release into the atmosphere. The
original, modified and effective UNIFAC models were used in this
work. The thirteen selected VOCs that have been considered in this
research are: pentane, hexane, heptanes, trimethylamine, toluene,
xylene, cyclohexane, butyl acetate, diethyl acetate, chloroform,
acetone, ethyl methyl ketone and isobutyl methyl ketone. The
computation was done for solute VOC concentration of 8.55x10-8
which is well in the infinite dilution region. The results obtained in
this study compare very well with those published in literature
obtained through both measurements and predictions. The phase
equilibrium obtained in this study show that PDMS is a good
absorbent for the removal of VOCs from contaminated air streams
through physical absorption.
Abstract: Phytophthora cinnamomi (P. c) is a plant pathogenic
oomycete that is capable of damaging plants in commercial production
systems and natural ecosystems worldwide. The most common
methods for the detection and diagnosis of P. c infection are
expensive, elaborate and time consuming. This study was carried out
to examine whether species specific and life cycle specific volatile
organic compounds (VOCs) can be absorbed by solid-phase
microextraction fibers and detected by gas chromatography that are
produced by P. c and another oomycete Pythium dissotocum. A
headspace solid-phase microextraction (HS-SPME) together with gas
chromatography (GC) method was developed and optimized for the
identification of the VOCs released by P. c. The optimized parameters
included type of fiber, exposure time, desorption temperature and
desorption time. Optimization was achieved with the analytes of P.
c+V8A and V8A alone. To perform the HS-SPME, six types of fiber
were assayed and compared: 7μm Polydimethylsiloxane (PDMS),
100μm Polydimethylsiloxane (PDMS), 50/30μm
Divinylbenzene/CarboxenTM/Polydimethylsiloxane
DVB/CAR/PDMS), 65μm Polydimethylsiloxane/Divinylbenzene
(PDMS/DVB), 85μm Polyacrylate (PA) fibre and 85μm CarboxenTM/
Polydimethylsiloxane (Carboxen™/PDMS). In a comparison of the
efficacy of the fibers, the bipolar fiber DVB/CAR/PDMS had a higher
extraction efficiency than the other fibers. An exposure time of 16h
with DVB/CAR/PDMS fiber in the sample headspace was enough to
reach the maximum extraction efficiency. A desorption time of 3min
in the GC injector with the desorption temperature of 250°C was
enough for the fiber to desorb the compounds of interest. The chromatograms and morphology study confirmed that the VOCs from
P. c+V8A had distinct differences from V8A alone, as did different
life cycle stages of P. c and different taxa such as Pythium dissotocum.
The study proved that P. c has species and life cycle specific VOCs,
which in turn demonstrated the feasibility of this method as means of
Abstract: In this paper, a simple microfluidic device for monitoring algal cell behavior is proposed. An array of algal microwells is fabricated by PDMS soft-lithography using X-ray LIGA mold, placed on a glass substrate. Two layers of replicated PDMS and substrate are attached by oxygen plasma bonding, creating a microchannel for the microfluidic system. Algal cell are loaded into the microfluidic device, which provides positive charge on the bottom surface of wells. Algal cells, which are negative charged, can be attracted to the bottom of the wells via electrostatic interaction. By varying the concentration of algal cells in the loading suspension, it is possible to obtain wells with a single cell. Liquid medium for cells monitoring are flown continuously over the wells, providing nutrient and waste exchange between the well and the main flow. This device could lead to the uncovering of the quantitative biology of the algae, which is a key to effective and extensive algal utilizations in the field of biotechnology, food industry and bioenergy research and developments.
Abstract: This study describes a micro device integrated with
multi-chamber for polymerase chain reaction (PCR) with different
annealing temperatures. The device consists of the reaction
polydimethylsiloxane (PDMS) chip, a cover glass chip, and is
equipped with cartridge heaters, fans, and thermocouples for
temperature control. In this prototype, commercial software is utilized
to determine the geometric and operational parameters those are
responsible for creating the denaturation, annealing, and extension
temperatures within the chip. Two cartridge heaters are placed at two
sides of the chip and maintained at two different temperatures to
achieve a thermal gradient on the chip during the annealing step. The
temperatures on the chip surface are measured via an infrared imager.
Some thermocouples inserted into the reaction chambers are used to
obtain the transient temperature profiles of the reaction chambers
during several thermal cycles. The experimental temperatures
compared to the simulated results show a similar trend. This work
should be interesting to persons involved in the high-temperature
based reactions and genomics or cell analysis.
Abstract: Aroma forming volatiles are important components of
fermented beverages. The aim of current research is to evaluate the
volatile compounds and phenolic compounds of commercial ciders.
Volatile aroma compounds and TPC of seven commercial ciders
were determined. Extraction of aroma compounds was performed
using solid phase microextraction (DVB/Car/PDMS fibre). Analysis
of volatile aroma compounds was made using a Perkin Elmer Clarus
500 GC/MS. Total phenol content (TPC) was determined according
to the Folin-Ciocalteu spectrophotometric method and results were
expressed as gallic acid equivalents. The highest volatile compounds
were in apple ciders with pear flavor. The highest TPC and lower
content of volatile compounds were detected in French ciders.
Abstract: This paper is a continuation of our interest in the influence of temperature on specific retention volumes and the resulting infinite dilution activity coefficients. This has a direct effect in the design of absorption and stripping columns for the abatement of volatile organic compounds. The interaction of 13 volatile organic compounds (VOCs) with polydimethylsiloxane (PDMS) at varying temperatures was studied by gas liquid chromatography (GLC). Infinite dilution activity coefficients and specific retention volumes obtained in this study were found to be in agreement with those obtained from static headspace and group contribution methods by the authors as well as literature values for similar systems. Temperature variation also allows for transport calculations for different seasons. The results of this work confirm that PDMS is well suited for the scrubbing of VOCs from waste gas streams. Plots of specific retention volumes against temperature gave linear van-t Hoff plots.
Abstract: The lubricating properties of commercially available
mucins originating from different animal organs, namely bovine
submaxillary mucin (BSM) and porcine gastric mucin (PGM), have
been characterized at polymeric surfaces for biomedical applications.
Atomic force microscopy (AFM) and pin-on-disk tribometry have
been employed for tribological studies at nanoscale and macroscale
contacts, respectively. Polystyrene (PS) was employed to represent
‘rigid’ contacts, whereas poly(dimethylsiloxane) (PDMS) was
employed to represent ‘soft contacts’. To understand the lubricating
properties of mucins in correlation with the coverage on surfaces,
adsorption properties of mucins onto the polymeric substrates have
been characterized by means of optical waveguide light-mode
spectroscopy (OWLS). Both mucins showed facile adsorption onto
both polymeric substrates, but the lubricity was highly dependent
upon the pH change between 2 and 7.
Abstract: PDMS (Polydimethylsiloxane) polymer is a suitable material for biological and MEMS (Microelectromechanical systems) designers, because of its biocompatibility, transparency and high resistance under plasma treatment. PDMS round channel is always been of great interest due to its ability to confine the liquid with membrane type micro valves. In this paper we are presenting a very simple way to form round shapemicrofluidic channel, which is based on reflow of positive photoresist AZ® 40 XT. With this method, it is possible to obtain channel of different height simply by varying the spin coating parameters of photoresist.
Abstract: Recently, the advanced technologies that offer high
precision product, relative easy, economical process and also rapid
production are needed to realize the high demand of ultra precision
micro part. In our research, micromanufacturing based on soft
lithography and nanopowder injection molding was investigated. The
silicone metal pattern with ultra thick and high aspect ratio succeeds to
fabricate Polydimethylsiloxane (PDMS) micro mold. The process
followed by nanopowder injection molding (PIM) by a simple vacuum
hot press. The 17-4ph nanopowder with diameter of 100 nm, succeed
to be injected and it forms green sample microbearing with thickness,
microchannel and aspect ratio is 700μm, 60μm and 12, respectively.
Sintering process was done in 1200 C for 2 hours and heating rate
0.83oC/min. Since low powder load (45% PL) was applied to achieve
green sample fabrication, ~15% shrinkage happen in the 86% relative
density. Several improvements should be done to produce high
accuracy and full density sintered part.