Abstract: Water is the most important and valuable resource not only for human life but also for all living things on the planet. The water supply utilities should fulfill the water requirement quantitatively and qualitatively. Drinking water systems are exposed to both natural (hurricanes and flood) and manmade hazards (risks) that are common in Palestine. Non-Revenue Water (NRW) is a manmade risk which remains a major concern in Palestine, as the NRW levels are estimated to be at a high level. In this research, Hebron city water distribution network was taken as a case study to estimate and audit the NRW levels. The research also investigated the state of the existing water distribution system in the study area by investigating the water losses and obtained more information on NRW prevention and management practices. Data and information have been collected from the Palestinian Water Authority (PWA) and Hebron Municipality (HM) archive. In addition to that, a questionnaire has been designed and administered by the researcher in order to collect the necessary data for water auditing. The questionnaire also assessed the views of stakeholder in PWA and HM (staff) on the current status of the NRW in the Hebron water distribution system. The important result obtained by this research shows that NRW in Hebron city was high and in excess of 30%. The main factors that contribute to NRW were the inaccuracies in billing volumes, unauthorized consumption, and the method of estimating consumptions through faulty meters. Policy for NRW reduction is available in Palestine; however, it is clear that the number of qualified staff available to carry out the activities related to leak detection is low, and that there is a lack of appropriate technologies to reduce water losses and undertake sufficient system maintenance, which needs to be improved to enhance the performance of the network and decrease the level of NRW losses.
Abstract: Based on the acoustics cascade sound theory, the mechanism of air leak sound producing, transmitting and signal detecting has been analyzed. A formula of the sound power, leak size and air pressure in the spacecraft has been built, and the relationship between leak sound pressure and receiving direction and distance has been studied. The center frequency in millimeter diameter leak is more than 20 kHz. The situation of air leaking from spacecraft to space has been simulated and an experiment of different leak size and testing distance and direction has been done. The sound pressure is in direct proportion to the cosine of the angle of leak to sensor. The portable ultrasonic leak detector has been developed, whose minimal leak rate is 10-1 Pa·m3/s, the testing radius is longer than 20 mm, the mass is less than 1.0 kg, and the electric power is less than 2.2 W.
Abstract: In this paper, an effective non-destructive, noninvasive
approach for leak detection was proposed. The process relies
on analyzing thermal images collected by an IR viewer device that
captures thermo-grams. In this study a statistical analysis of the
collected thermal images of the ground surface along the expected
leak location followed by a visual inspection of the thermo-grams
was performed in order to locate the leak. In order to verify the
applicability of the proposed approach the predicted leak location
from the developed approach was compared with the real leak
location. The results showed that the expected leak location was
successfully identified with an accuracy of more than 95%.
Abstract: There are a many of needs for the development of
SiC-based hydrogen sensor for harsh environment applications. We
fabricated and investigated Pd/Ta2O5/SiC-based hydrogen sensors
with MOS capacitor structure for high temperature process monitoring
and leak detection applications in such automotive, chemical and
petroleum industries as well as direct monitoring of combustion
processes. In this work, we used silicon carbide (SiC) as a substrate to
replace silicon which operating temperatures are limited to below
200°C. Tantalum oxide was investigated as dielectric layer which has
high permeability for hydrogen gas and high dielectric permittivity,
compared with silicon dioxide or silicon nitride. Then, electrical
response properties, such as I-V curve and dependence of capacitance
on hydrogen concentrations were analyzed in the temperature ranges
of room temperature to 500°C for performance evaluation of the
sensor.
Abstract: Due to memory leaks, often-valuable system memory
gets wasted and denied for other processes thereby affecting the
computational performance. If an application-s memory usage
exceeds virtual memory size, it can leads to system crash. Current
memory leak detection techniques for clusters are reactive and
display the memory leak information after the execution of the
process (they detect memory leak only after it occur).
This paper presents a Dynamic Memory Monitoring Agent
(DMMA) technique. DMMA framework is a dynamic memory leak
detection, that detects the memory leak while application is in
execution phase, when memory leak in any process in the cluster is
identified by DMMA it gives information to the end users to enable
them to take corrective actions and also DMMA submit the affected
process to healthy node in the system. Thus provides reliable service
to the user. DMMA maintains information about memory
consumption of executing processes and based on this information
and critical states, DMMA can improve reliability and
efficaciousness of cluster computing.
Abstract: In this paper two mathematical models for definition of gas accidental escape localization in the gas pipelines are suggested. The first model was created for leak localization in the horizontal branched pipeline and second one for leak detection in inclined section of the main gas pipeline. The algorithm of leak localization in the branched pipeline did not demand on knowledge of corresponding initial hydraulic parameters at entrance and ending points of each sections of pipeline. For detection of the damaged section and then leak localization in this section special functions and equations have been constructed. Some results of calculations for compound pipelines having two, four and five sections are presented. Also a method and formula for the leak localization in the simple inclined section of the main gas pipeline are suggested. Some results of numerical calculations defining localization of gas escape for the inclined pipeline are presented.
Abstract: Intelligent technologies are increasingly facilitating
sustainable water management strategies in Australia. While this
innovation can present clear cost benefits to utilities through
immediate leak detection and deference of capital costs, the impact of
this technology on households is less distinct. By offering real-time
engagement and detailed end-use consumption breakdowns, there is
significant potential for demand reduction as a behavioural response
to increased information. Despite this potential, passive
implementation without well-planned residential engagement
strategies is likely to result in a lost opportunity. This paper begins
this research process by exploring the effect of smart water meters
through the lens of three behaviour change theories. The Theory of
Planned Behaviour (TPB), Belief Revision theory (BR) and Practice
Theory emphasise different variables that can potentially influence
and predict household water engagements. In acknowledging the
strengths of each theory, the nuances and complexity of household
water engagement can be recognised which can contribute to
effective planning for residential smart meter engagement strategies.