Abstract: Feature selection and attribute reduction are crucial
problems, and widely used techniques in the field of machine
learning, data mining and pattern recognition to overcome the
well-known phenomenon of the Curse of Dimensionality. This paper
presents a feature selection method that efficiently carries out attribute
reduction, thereby selecting the most informative features of a dataset.
It consists of two components: 1) a measure for feature subset
evaluation, and 2) a search strategy. For the evaluation measure,
we have employed the fuzzy-rough dependency degree (FRFDD)
of the lower approximation-based fuzzy-rough feature selection
(L-FRFS) due to its effectiveness in feature selection. As for the
search strategy, a modified version of a binary shuffled frog leaping
algorithm is proposed (B-SFLA). The proposed feature selection
method is obtained by hybridizing the B-SFLA with the FRDD. Nine
classifiers have been employed to compare the proposed approach
with several existing methods over twenty two datasets, including
nine high dimensional and large ones, from the UCI repository.
The experimental results demonstrate that the B-SFLA approach
significantly outperforms other metaheuristic methods in terms of the
number of selected features and the classification accuracy.
Abstract: Supermarkets are the most electricity-intensive type of
commercial buildings. The unsuitable indoor environment of a
supermarket provided by abnormal HVAC operations incurs waste
energy consumption in refrigeration systems. This current study
briefly describes significantly solid backgrounds and proposes easyto-
use analysis terminology for investigating the impact of HVAC
operations on refrigeration power consumption using the field-test
data obtained from building automation system (BAS). With solid
backgrounds and prior knowledge, expected energy interactions
between HVAC and refrigeration systems are proposed through
Pearson’s correlation analysis (R value) by considering correlations
between equipment power consumption and dominantly independent
variables (driving force conditions).The R value can be conveniently
utilized to evaluate how strong relations between equipment
operations and driving force parameters are. The calculated R values
obtained from field data are compared to expected ranges of R values
computed by energy interaction methodology. The comparisons can
separate the operational conditions of equipment into faulty and
normal conditions. This analysis can simply investigate the condition
of equipment operations or building sensors because equipment could
be abnormal conditions due to routine operations or faulty
commissioning processes in field tests. With systematically solid and
easy-to-use backgrounds of interactions provided in the present
article, the procedures can be utilized as a tool to evaluate the proper
commissioning and routine operations of HVAC and refrigeration
systems to detect simple faults (e.g. sensors and driving force
environment of refrigeration systems and equipment set-point) and
optimize power consumption in supermarket buildings. Moreover,
the analysis will be used to further study the FDD research for
supermarkets in future.
Abstract: Historically, actuators’ redundancy was used to deal
with faults occurring suddenly in flight systems. This technique was
generally expensive, time consuming and involves increased weight
and space in the system. Therefore, nowadays, the on-line fault
diagnosis of actuators and accommodation plays a major role in the
design of avionic systems. These approaches, known as Fault
Tolerant Flight Control systems (FTFCs) are able to adapt to such
sudden faults while keeping avionics systems lighter and less
expensive. In this paper, a (FTFC) system based on the Geometric
Approach and a Reconfigurable Flight Control (RFC) are presented.
The Geometric approach is used for cosmic ray fault reconstruction,
while Sliding Mode Control (SMC) based on Lyapunov stability
theory is designed for the reconfiguration of the controller in order to
compensate the fault effect. Matlab®/Simulink® simulations are
performed to illustrate the effectiveness and robustness of the
proposed flight control system against actuators’ faulty signal caused
by cosmic rays. The results demonstrate the successful real-time
implementation of the proposed FTFC system on a non-linear 6 DOF
aircraft model.
Abstract: The present analysis considers the steady stagnation point flow and heat transfer towards a permeable shrinking sheet in an upper-convected Maxwell (UCM) electrically conducting fluid, with a constant magnetic field applied in the transverse direction to flow and a local heat generation within the boundary layer, with a heat generation rate proportional to (T-T)p Using a similarity transformation, the governing system of partial differential equations is first transformed into a system of ordinary differential equations, which is then solved numerically using a finite-difference scheme known as the Keller-box method. Numerical results are obtained for the flow and thermal fields for various values of the stretching/shrinking parameter λ, the magnetic parameter M, the elastic parameter K, the Prandtl number Pr, the suction parameter s, the heat generation parameter Q, and the exponent p. The results indicate the existence of dual solutions for the shrinking sheet up to a critical value λc whose value depends on the value of M, K, and s. In the presence of internal heat absorption (Q
Abstract: In this paper, an adaptive polarized Multiple-Input
Multiple-Output (MIMO) Multicarrier Spread Spectrum Code Division Multiple Access (MC-SS-CDMA) system is designed for downlink mobile communications. The proposed system will be
examined in Frequency Division Duplex (FDD) mode for both macro urban and suburban environments. For the same transmission
bandwidth, a performance comparison between both nonoverlapped and orthogonal Frequency Division Multiplexing (FDM) schemes will be presented. Also, the proposed system will be compared with
both the closed loop vertical MIMO MC-SS-CDMA system and the
synchronous vertical STBC-MIMO MC-SS-CDMA system. As will
be shown, the proposed system introduces a significant performance
gain as well as reducing the spatial dimensions of the MIMO system
and simplifying the receiver implementation. The effect of the
polarization diversity characteristics on the BER performance will be
discussed. Also, the impact of excluding the cross-polarization MCSS-
CDMA blocks in the base station will be investigated. In addition,
the system performance will be evaluated under different Feedback
Information (FBI) rates for slowly-varying channels. Finally, a
performance comparison for vehicular and pedestrian environments
will be presented
Abstract: One of the biggest drawbacks of the wireless
environment is the limited bandwidth. However, the users sharing
this limited bandwidth have been increasing considerably. SDMA
technique which entails using directional antennas allows to increase
the capacity of a wireless network by separating users in the medium.
In this paper, it has been presented how the capacity can be enhanced
while the mean delay is reduced by using directional antennas in
wireless networks employing TDMA/FDD MAC. Computer
modeling and simulation of the wireless system studied are realized
using OPNET Modeler. Preliminary simulation results are presented
and the performance of the model using directional antennas is
evaluated and compared consistently with the one using
omnidirectional antennas.
Abstract: The asymmetric trafc between uplink and downlink
over recent mobile communication systems has been conspicuous because
of providing new communication services. This paper proposes
an asymmetric trafc accommodation scheme adopting a multihop
cooperative transmission technique for CDMA/FDD cellular networks.
The proposed scheme employs the cooperative transmission
technique in the already proposed downlink multihop transmissions
for the accommodation of the asymmetric trafc, which utilizes
the vacant uplink band for the downlink relay transmissions. The
proposed scheme reduces the transmission power at the downlink
relay transmissions and then suppresses the interference to the uplink
communications, and thus, improves the uplink performance. The
proposed scheme is evaluated by computer simulation and the results
show that it can achieve better throughput performance.
Abstract: In a BFWA (Broadband Fixed Wireless Access Network) the evolved SINR (Signal to Interference plus Noise Ratio) is relevant influenced by the applied duplex method. The TDD (Time Division Duplex), especially adaptive TDD method has some advantage contrary to FDD (Frequency Division Duplex), for example the spectrum efficiency and flexibility. However these methods are suffering several new interference situations that can-t occur in a FDD system. This leads to reduced SINR in the covered area what could cause some connection outages. Therefore, countermeasure techniques against interference are necessary to apply in TDD systems. Synchronization is one way to handling the interference. In this paper the TDD systems – applying different system synchronization degree - will be compared by the evolved SINR at different locations of the BFWA service area and the percentage of the covered area by the system.
Abstract: Modern manufacturing facilities are large scale,
highly complex, and operate with large number of variables under
closed loop control. Early and accurate fault detection and diagnosis
for these plants can minimise down time, increase the safety of plant
operations, and reduce manufacturing costs. Fault detection and
isolation is more complex particularly in the case of the faulty analog
control systems. Analog control systems are not equipped with
monitoring function where the process parameters are continually
visualised. In this situation, It is very difficult to find the relationship
between the fault importance and its consequences on the product
failure. We consider in this paper an approach to fault detection and
analysis of its effect on the production quality using an adaptive
centring and scaling in the pickling process in cold rolling. The fault
appeared on one of the power unit driving a rotary machine, this
machine can not track a reference speed given by another machine.
The length of metal loop is then in continuous oscillation, this affects
the product quality. Using a computerised data acquisition system,
the main machine parameters have been monitored. The fault has
been detected and isolated on basis of analysis of monitored data.
Normal and faulty situation have been obtained by an artificial neural
network (ANN) model which is implemented to simulate the normal
and faulty status of rotary machine. Correlation between the product
quality defined by an index and the residual is used to quality
classification.