Abstract: Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC’s dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS’s primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.
Abstract: The energy audit is the essential initial step to ensure a good definition of energy control actions. The in-depth study of the various energy-consuming equipments makes it possible to determine the actions and investments with best cost for the company. The analysis focuses on the energy consumption of production equipment and utilities (lighting, heating, air conditioning, ventilation, transport). Successful implementation of this approach requires, however, to take into account a number of prerequisites. This paper proposes a number of useful recommendations concerning the energy audit in order to achieve better results, and a case study concerning the lighting audit of a Moroccan company by showing the gains that can be made through this audit.
Abstract: Residential buildings fund of Kazakhstan was built in the Soviet time about 35-60 years ago without considering energy efficiency measures. Currently, most of these buildings are in a rundown condition and fail to meet the minimum of hygienic, sanitary and comfortable living requirements. The paper aims to examine the reports of recent building energy survey activities in the country and provide a possible solution for retrofitting existing housing stock built before 1989 which could be applicable for building envelope in cold climate. Methodology also includes two-dimensional modeling of possible practical solutions and further recommendations.
Abstract: Agro based industries in India are considered as the micro, small and medium enterprises (MSME). In India, MSMEs contribute approximately 8 percent of the country’s GDP, 42 percent of the manufacturing output and 40 percent of exports. The toor dal (scientific name Cajanus cajan, commonly known as yellow gram, pigeon pea) is the second largest pulse crop in India accounting for about 20% of total pulse production. The toor dal milling industry in India is one of the major agro-processing industries in the country. Most of the dal mills are concentrated in pulse producing areas, which are spread all over the country. In Karnataka state, Gulbarga is a district, where toor dal is the main crop and is grown extensively. There are more than 500 dal mills in and around the Gulbarga district to process dal. However, the majority of these dal milling units use traditional methods of processing which are energy and capital intensive. There exists a huge energy saving potential in these mills. An energy audit is conducted on a dal mill in Gulbarga to understand the energy consumption pattern to assess the energy saving potential, and an economic analysis is conducted to identify energy conservation opportunities.
Abstract: In most existing buildings in hot climate, cooling
loads lead to high primary energy consumption and consequently
high CO2 emissions. These can be substantially decreased with
integrated renewable energy systems. Kuwait is characterized by its
dry hot long summer and short warm winter. Kuwait receives annual
total radiation more than 5280 MJ/m2 with approximately 3347 h of
sunshine. Solar energy systems consist of PV modules and parabolic
trough collectors are considered to satisfy electricity consumption,
domestic water heating, and cooling loads of an existing building.
This paper presents the results of an extensive program of energy
conservation and energy generation using integrated photovoltaic
(PV) modules and Parabolic Trough Collectors (PTC). The program
conducted on an existing institutional building intending to convert it
into a Net-Zero Energy Building (NZEB) or near net Zero Energy
Building (nNZEB). The program consists of two phases; the first
phase is concerned with energy auditing and energy conservation
measures at minimum cost and the second phase considers the
installation of photovoltaic modules and parabolic trough collectors.
The 2-storey building under consideration is the Applied Sciences
Department at the College of Technological Studies, Kuwait. Single
effect lithium bromide water absorption chillers are implemented to
provide air conditioning load to the building. A numerical model is
developed to evaluate the performance of parabolic trough collectors
in Kuwait climate. Transient simulation program (TRNSYS) is
adapted to simulate the performance of different solar system
components. In addition, a numerical model is developed to assess
the environmental impacts of building integrated renewable energy
systems. Results indicate that efficient energy conservation can play
an important role in converting the existing buildings into NZEBs as
it saves a significant portion of annual energy consumption of the
building. The first phase results in an energy conservation of about
28% of the building consumption. In the second phase, the integrated
PV completely covers the lighting and equipment loads of the
building. On the other hand, parabolic trough collectors of optimum
area of 765 m2 can satisfy a significant portion of the cooling load,
i.e about73% of the total building cooling load. The annual avoided
CO2 emission is evaluated at the optimum conditions to assess the
environmental impacts of renewable energy systems. The total annual
avoided CO2 emission is about 680 metric ton/year which confirms
the environmental impacts of these systems in Kuwait.
Abstract: The increase in energy demand has raised concerns
over adverse impacts on the environment from energy generation. It
is important to understand the status of energy consumption for
institutions such as Curtin Sarawak to ensure the sustainability of
energy usage, and also to reduce its costs. In this study, a preliminary
audit framework was developed and was conducted around the
Malaysian campus to obtain information such as the number and
specifications of electrical appliances, built-up area and ambient
temperature to understand the relationship of these factors with
energy consumption. It was found that the number and types of
electrical appliances, population and activities in the campus
impacted the energy consumption of Curtin Sarawak directly.
However, the built-up area and ambient temperature showed no clear
correlation with energy consumption. An investigation of the diurnal
and seasonal energy consumption of the campus was also carried out.
From the data, recommendations were made to improve the energy
efficiency of the campus.