Abstract: In this work, efficient directional coupler composed of
dielectric waveguides and metallic film has been analyzed in details
by simulations using finite element method (FEM). The structure
consists of a step-index fiber with dielectric core, silica cladding, and
a metal nanowire parallel to the core. The results show that an
efficient conversion of optical dielectric modes to long range
plasmonic is possible. Low insertion losses in conjunction with short
coupling length and a broadband operation can be achieved under
certain conditions. This kind of couplers has potential applications for
the design of photonic integrated circuits for signal routing between
dielectric/plasmonic waveguides, sensing, lithography, and optical
storage systems. A high efficient focusing of light in a very small
region can be obtained.
Abstract: In this paper, by exploiting a single semiconductor
optical amplifier-Mach Zehnder Interferometer (SOA-MZI), an
integratable all-optical flip-flop (AOFF) is proposed. It is composed
of a SOA-MZI with a bidirectional coupler at the output. Output
signals of both bar and crossbar of the SOA-MZI is fed back to SOAs
located in the arms of the Mach-Zehnder Interferometer (MZI). The
injected photon-rates to the SOAs are modulated by feedback signals
in order to form optical flip-flop. According to numerical analysis,
Gaussian optical pulses with the energy of 15.2 fJ and 20 ps duration
with the full width at half-maximum criterion, can switch the states of
the SR-AOFF. Also simulation results show that the SR-AOFF has
the contrast ratio of 8.5 dB between two states with the transition
time of nearly 20 ps.
Abstract: The purpose of this study is to present a non invasive
method for the marginal adaptation evaluation in class V composite
restorations. Standardized class V cavities, prepared in human
extracted teeth, were filled with Premise (Kerr) composite. The
specimens were thermo cycled. The interfaces were examined by
Optical Coherence Tomography method (OCT) combined with the
confocal microscopy and fluorescence. The optical configuration
uses two single mode directional couplers with a superluminiscent
diode as the source at 1300 nm. The scanning procedure is similar to
that used in any confocal microscope, where the fast scanning is enface
(line rate) and the depth scanning is much slower (at the frame
rate). Gaps at the interfaces as well as inside the composite resin
materials were identified. OCT has numerous advantages which
justify its use in vivo as well as in vitro in comparison with
conventional techniques.