Abstract: In this paper, the effect of the injected current and temperature into the output power of the laser diode module operating at 808nm were applied, studied and discussed. Low power diode laser was employed as a source. The experimental results were demonstrated and then the output power of laser diode module operating at 808nm was clearly changed by the thermal temperature and injected current. The output power increases by the increasing the injected current and temperature. We also showed that the increasing of the injected current results rising in heat, which also, results into decreasing of the laser diode output power during the highest temperature as well. The best ranges of characteristics made by diode module operating at 808nm were carefully handled and determined.
Abstract: A laser is essentially an optical oscillator consisting of a resonant cavity, an amplifying medium and a pumping source. In semiconductor diode lasers, the cavity is created by the boundary between the cleaved face of the semiconductor crystal and air, and has reflective properties as a result of the differing refractive indices of the two media. For a GaAs-air interface a reflectance of 0.3 is typical and therefore the length of the semiconductor junction forms the resonant cavity. To prevent light being emitted in unwanted directions from the junction, sides perpendicular to the required direction are roughened. The objective of this work is to simulate the optical resonator Fabry-Perot and explore its main characteristics, such as FSR, finesse, linewidth, transmission and so on, that describe the performance of resonator.
Abstract: The dynamic speckle or biospeckle is an interference
phenomenon generated at the reflection of a coherent light by an
active surface or even by a particulate or living body surface. The
above mentioned phenomenon gave scientific support to a method
named biospeckle which has been employed to study seed viability,
biological activity, tissue senescence, tissue water content, fruit
bruising, etc. Since the above mentioned method is not invasive and
yields numerical values, it can be considered for possible automation
associated to several processes, including selection and sorting.
Based on these preliminary considerations, this research work
proposed to study the interaction of a laser beam with vegetative
samples by measuring the incident light intensity and the transmitted
light beam intensity at several vegetative slabs of varying thickness.
Tests were carried on fifteen slices of apple tissue divided into three
thickness groups, i.e., 4 mm, 5 mm, 18 mm and 22 mm. A diode laser
beam of 10mW and 632 nm wavelength and a Samsung digital
camera were employed to carry the tests. Outgoing images were
analyzed by comparing the gray gradient of a fixed image column of
each image to obtain a laser penetration scale into the tissue,
according to the slice thickness.
Abstract: In the present investigation, H13 tool steel has been
deposited on copper alloy substrate using both CO2 and diode laser.
A detailed parametric analysis has been carried out in order to find
out optimum processing zone for coating defect free H13 tool steel
on copper alloy substrate. Followed by parametric optimization, the
microstructure and microhardness of the deposited clads have been
evaluated. SEM micrographs revealed dendritic microstructure in
both clads. However, the microhardness of CO2 laser deposited clad
was much higher compared to diode laser deposited clad.
Abstract: Gold coated silica core nanoparticles have an optical
response dictated by the plasmon resonance. The wavelength at
which the resonance occurs depends on the core and shell sizes,
allowing nanoshells to be tailored for particular applications. The
purposes of this study was to synthesize and use different
concentration of gold nanoshells as exogenous material for skin
tissue soldering and also to examine the effect of laser soldering
parameters on the properties of repaired skin. Two mixtures of
albumin solder and different concentration of gold nanoshells were
prepared. A full thickness incision of 2×20 mm2 was made on the
surface and after addition of mixtures it was irradiated by an 810nm
diode laser at different power densities. The changes of tensile
strength σt due to temperature rise, number of scan (Ns), and scan
velocity (Vs) were investigated. The results showed at constant laser
power density (I), σt of repaired incisions increases by increasing the
concentration of gold nanoshells, Ns and decreasing Vs. It is therefore
important to consider the trade off between the scan velocity and the
surface temperature for achieving an optimum operating condition. In
our case this corresponds to σt =1610 gr/cm2 at I~ 60 Wcm-2, T ~
65ºC, Ns =10 and Vs=0.2mms-1.
Abstract: In this study we applied thermal lens (TL) technique
to study the effect of size on thermal diffusivity of cadmium sulphide
(CdS) nanofluid prepared by using γ-radiation method containing
particles with different sizes. In TL experimental set up a diode laser
of wavelength 514 nm and intensity stabilized He-Ne laser were used
as the excitation source and the probe beam respectively,
respectively. The experimental results showed that the thermal
diffusivity value of CdS nanofluid increases when the of particle size
increased.
Abstract: The technical realization of data transmission using
glass fiber began after the development of diode laser in year 1962.
The erbium doped fiber amplifiers (EDFA's) in high speed networks
allow information to be transmitted over longer distances without
using of signal amplification repeaters. These kinds of fibers are
doped with erbium atoms which have energy levels in its atomic
structure for amplifying light at 1550nm. When a carried signal wave
at 1550nm enters the erbium fiber, the light stimulates the excited
erbium atoms which pumped with laser beam at 980nm as additional
light. The wavelength and intensity of the semiconductor lasers
depend on the temperature of active zone and the injection current.
The present paper shows the effect of the diode lasers temperature
and injection current on the optical amplification. From the results of
in- and output power one may calculate the max. optical gain by
erbium doped fiber amplifier.
Abstract: Nowadays, quasi-continuous wave diode lasers are
used in a widespread variety of applications. Temperature effects in
these lasers can strongly influence their performance. In this paper,
the effects of temperature have been experimentally investigated on
different features of a 60W-QCW diode laser. The obtained results
indicate that the conversion efficiency and operation voltage of diode
laser decrease with the augmentation of the working temperature
associated with a redshift in the laser peak wavelength. Experimental
results show the emission peak wavelength of laser shifts 0.26 nm
and the conversion efficiency decreases 1.76 % with the increase of
temperature from 40 to 50 ̊C. Present study also shows the slope
efficiency decreases gradually at low temperatures and rapidly at
higher temperatures. Regarding the close dependence of the
mentioned parameters to the operating temperature, it is of great
importance to carefully control the working temperature of diode
laser, particularly for medical applications.
Abstract: Laser soldering is based on applying some soldering material (albumin) onto the approximated edges of the cut and heating the solder (and the underlying tissues) by a laser beam. Endogenous and exogenous materials such as indocyanine green (ICG) are often added to solders to enhance light absorption. Gold nanoshells are new materials which have an optical response dictated by the plasmon resonance. The wavelength at which the resonance occurs depends on the core and shell sizes, allowing nanoshells to be tailored for particular applications. The purposes of this study was use combination of ICG and different concentration of gold nanoshells for skin tissue soldering and also to examine the effect of laser soldering parameters on the properties of repaired skin. Two mixtures of albumin solder and different combinations of ICG and gold nanoshells were prepared. A full thickness incision of 2×20 mm2 was made on the surface and after addition of mixtures it was irradiated by an 810nm diode laser at different power densities. The changes of tensile strength σt due to temperature rise, number of scan (Ns), and scan velocity (Vs) were investigated. The results showed at constant laser power density (I), σt of repaired incisions increases by increasing the concentration of gold nanoshells in solder, Ns and decreasing Vs. It is therefore important to consider the tradeoff between the scan velocity and the surface temperature for achieving an optimum operating condition. In our case this corresponds to σt =1800 gr/cm2 at I~ 47 Wcm-2, T ~ 85ºC, Ns =10 and Vs=0.3mms-1.
Abstract: The process of laser absorption in the skin during
laser irradiation was a critical point in medical application
treatments. Delivery the correct amount of laser light is a critical
element in photodynamic therapy (PDT). More amounts of laser
light able to affect tissues in the skin and small amount not able to
enhance PDT procedure in skin. The knowledge of the skin tone
laser dependent distribution of 635 nm radiation and its penetration
depth in skin is a very important precondition for the investigation of
advantage laser induced effect in (PDT) in epidermis diseases
(psoriasis). The aim of this work was to estimate an optimum effect
of diode laser (635 nm) on the treatment of epidermis diseases in
different color skin. Furthermore, it is to improve safety of laser in
PDT in epidermis diseases treatment. Advanced system analytical
program (ASAP) which is a new approach in investigating the PDT,
dependent on optical properties of different skin color was used in
present work. A two layered Realistic Skin Model (RSM); stratum
corneum and epidermal with red laser (635 nm, 10 mW) were used
for irradiative transfer to study fluence and absorbance in different
penetration for various human skin colors. Several skin tones very
fair, fair, light, medium and dark are used to irradiative transfer. This
investigation involved the principles of laser tissue interaction when
the skin optically injected by a red laser diode. The results
demonstrated that the power characteristic of a laser diode (635 nm)
can affect the treatment of epidermal disease in various color skins.
Power absorption of the various human skins were recorded and
analyzed in order to find the influence of the melanin in PDT
treatment in epidermal disease. A two layered RSM show that the
change in penetration depth in epidermal layer of the color skin has a
larger effect on the distribution of absorbed laser in the skin; this is
due to the variation of the melanin concentration for each color.