Abstract: Almost all of the domestic refrigerators operate on the principle of the vapor compression refrigeration cycle and removal of heat from the refrigerator cabinets is done via one of the two methods: natural convection or forced convection. In this study, airflow and temperature distributions inside a 375L no-frost type larder cabinet, in which cooling is provided by forced convection, are evaluated both experimentally and numerically. Airflow rate, compressor capacity and temperature distribution in the cooling chamber are known to be some of the most important factors that affect the cooling performance and energy consumption of a refrigerator. The objective of this study is to evaluate the original temperature distribution in the larder cabinet, and investigate for better temperature distribution solutions throughout the refrigerator domain via system optimizations that could provide uniform temperature distribution. The flow visualization and airflow velocity measurements inside the original refrigerator are performed via Stereoscopic Particle Image Velocimetry (SPIV). In addition, airflow and temperature distributions are investigated numerically with Ansys Fluent. In order to study the heat transfer inside the aforementioned refrigerator, forced convection theories covering the following cases are applied: closed rectangular cavity representing heat transfer inside the refrigerating compartment. The cavity volume has been represented with finite volume elements and is solved computationally with appropriate momentum and energy equations (Navier-Stokes equations). The 3D model is analyzed as transient, with k-ε turbulence model and SIMPLE pressure-velocity coupling for turbulent flow situation. The results obtained with the 3D numerical simulations are in quite good agreement with the experimental airflow measurements using the SPIV technique. After Computational Fluid Dynamics (CFD) analysis of the baseline case, the effects of three parameters: compressor capacity, fan rotational speed and type of shelf (glass or wire) are studied on the energy consumption; pull down time, temperature distributions in the cabinet. For each case, energy consumption based on experimental results is calculated. After the analysis, the main effective parameters for temperature distribution inside a cabin and energy consumption based on CFD simulation are determined and simulation results are supplied for Design of Experiments (DOE) as input data for optimization. The best configuration with minimum energy consumption that provides minimum temperature difference between the shelves inside the cabinet is determined.
Abstract: The matrix cooling channel was used for gas turbine blade cooling passage. The matrix cooling structure is useful for the structure stability however the cooling performance of internal cooling channel was not enough for cooling. Therefore, we designed the rib configurations in the matrix cooling channel to enhance the cooling performance. The numerical simulation was conducted to analyze cooling performance of rib configured matrix cooling channel. Three different rib configurations were used which are vertical rib, angled rib and c-type rib. Three configurations were adopted in two positions of matrix cooling channel which is one fourth and three fourth of channel. The result shows that downstream rib has much higher cooling performance than upstream rib. Furthermore, the angled rib in the channel has much higher cooling performance than vertical rib. This is because; the angled rib improves the swirl effect of matrix cooling channel more effectively. The friction factor was increased with the installation of rib. However, the thermal performance was increased with the installation of rib in the matrix cooling channel.
Abstract: Thermally Activated Building Systems (TABS) have proven to be an energy-efficient solution to provide buildings with an optimal indoor thermal environment. This solution uses the structure of the building to store heat, reduce the peak loads, and decrease the primary energy demand. TABS require the heated or cooled surfaces to be as exposed as possible to the indoor space, but exposing the bare concrete surfaces has a diminishing effect on the acoustic qualities of the spaces in a building. Acoustic solutions capable of providing optimal acoustic comfort and allowing the heat exchange between the TABS and the room are desirable. In this study, the effects of free-hanging units on the cooling performance of TABS and the occupants’ thermal comfort was measured in a full-scale TABS laboratory. Investigations demonstrate that the use of free-hanging sound absorbers are compatible with the performance of TABS and the occupant’s thermal comfort, but an appropriate acoustic design is needed to find the most suitable solution for each case. The results show a reduction of 11% of the cooling performance of the TABS when 43% of the ceiling area is covered with free-hanging horizontal sound absorbers, of 23% for 60% ceiling coverage ratio and of 36% for 80% coverage. Measurements in actual buildings showed an increase of the room operative temperature of 0.3 K when 50% of the ceiling surface is covered with horizontal panels and of 0.8 to 1 K for a 70% coverage ratio. According to numerical simulations using a new TRNSYS Type, the use of comfort ventilation has a considerable influence on the thermal conditions in the room; if the ventilation is removed, then the operative temperature increases by 1.8 K for a 60%-covered ceiling.
Abstract: When sinters are filled into the cooler from the sintering machine, and the non-uniform distribution of the sinters leads to uneven cooling. This causes the temperature difference of the sinters leaving the cooler to be so large that it results in the conveyors being deformed by the heat. The present work applies CFD method to investigate the thermo flowfield phenomena in a sinter cooler by the Porous Media Model. Using the obtained experimental data to simulate porosity (Ε), permeability (κ), inertial coefficient (F), specific heat (Cp) and effective thermal conductivity (keff) of the sinter packed beds. The physical model is a similar geometry whose Darcy numbers (Da) are similar to the sinter cooler. Using the Cooling Index (CI) and Uniformity Index (UI) to analyze the thermo flowfield in the sinter packed bed obtains the cooling performance of the sinter cooler.
Abstract: Using the numerical and experimental methods, this paper discusses some primary studies on the vibration and cooling performances of the piezoelectric cooling fan with the rectangular blade. When the fan works at its natural frequency, the vibrating displacement is largest and the cooling performance is best. Due to the vibration behavior, the cooling performance is affected by the geometry, material property, and working frequency of the piezoelectric cooling fan.
Abstract: Thermoacoustic refrigerator is a cooling device which
uses the acoustic waves to produce the cooling effect. The aim of this
paper is to explore the experimental and numerical feasibility of a
standing-wave thermoacoustic refrigerator. The effects of the stack
length, position of stack and operating frequency on the cooling
performance are carried out. The circular pore stacks are tested under
the atmospheric pressure. A low-cost loudspeaker is used as an
acoustic driver. The results show that the location of stack installed in
resonator tube has a greater effect on the cooling performance, than
the stack length and operating frequency, respectively. The
temperature difference across the ends of stack can be generated up
to 13.7°C, and the temperature of cold-end is dropped down by 5.3°C
from the ambient temperature.
Abstract: In this study, the experiments were carried out to
determine the best coolant for the quenching process among waterbased
silica, alumina, titania and copper oxide nanofluids (0.1 vol%).
A sphere made up off brass material was used in the experiments.
When the spherical test specimen was heated at high temperatures, it
was suddenly immersed into the nanofluids. All experiments were
carried out at saturated conditions and under atmospheric pressure.
After the experiments, the cooling curves were obtained by using the
temperature-time data of the specimen. The experimental results
showed that the cooling performance of test specimen depended on
the type of nanofluids. The silica nanoparticles enhanced the
performance of boiling heat transfer and it is the best coolant for the
quenching among other nanoparticles.
Abstract: In this experimental study, performance of a counter
flow Ranque-Hilsch vortex tube (RHVT) with threads cut on its inner
surface was investigated experimentally (pitch is 1 and 2 mm). The
inner diameter of the vortex tube used was D=9 mm and the ratio of
the tube’s length to diameter was L/D=12. The experimental system
was a thermodynamic open system. Flow was controlled by a valve
on the hot outlet side, where the valve was changed from a nearly
closed position to its nearly open position. Fraction of cold flow (ξ) =
0.1-0.9, was determined under 300 and 350 kPa pressurized air. All
experimental data were compared with each other, the maximum
heating performance of the RHVT system was found to be 38.2 oC
and the maximum cooling performance of the RHVT in this study
was found to be -30.9 oC at pitch 1 mm.
Abstract: In this paper a numerical technique is used to predict
the metal temperature of a gas turbine vane. The Rising combustor
exit temperatures in gas turbine engines necessitate active cooling for
the downstream turbine section to avoid thermal failure. This study is
performed the solution of external flow, internal convection, and
conduction within the metal vane. Also the trade-off between the
cooling performances in four different hole shapes and configurations
is performed. At first one of the commonly used cooling hole
geometry is investigated; cylindrical holes and then two other
configurations are simulated. The average temperature magnitude in
mid-plan section of each configuration is obtained and finally the
lower temperature value is selected such as best arrangement.
Abstract: This study experimentally and numerically investigates
motor cooling performance. The motor consists of a centrifugal fan,
two axial fans, a shaft, a stator, a rotor and a heat exchanger with 637
cooling tubes. The pressure rise-flow rate (P-Q) performance curves of
the cooling fans at 1800 rpm are tested using a test apparatus
complying with the Chinese National Standard (CNS) 2726.
Compared with the experimental measurements, the numerical
analysis results show that the P-Q performance curves of the axial fan
and centrifugal fan can be estimated within about 2% and 6%,
respectively. By using the simplified model, setting up the heat
exchanger and stator as porous media, the flow field in the motor is
calculated. By using the results of the flow field near the rotor and
stator, and subjecting the heat generation rate as a boundary condition,
the temperature distributions of the stator and rotor are also calculated.
The simulation results show that the calculated temperature of the
stator winding near the axial fans is lower by about 5% than the
measured value, and the calculated temperature of the stator core
located at the center of the stator is about 1% higher than the measured
value. Besides, discussion is made to improve the motor cooling
performance.
Abstract: This paper presents the results of the experimental
tests of the cooling performance of a 12,000-Btu/h modified air
conditioner (referred to as M-AC) that use the ground as a heat sink
of a condenser. In the tests, cooling capacity of M-AC with an
optimal length of a condensing coil as well as life expectancy of
copper coil buried underground were investigated. The lengths of
copper coil fabricated and used as condenser coil of M-AC were set
at 67, 50, 40 and 30 m whereas that of a 12,000-Btu/h conventional
split-type air conditioner (referred to as C-AC) was about 22 m. The
results showed that the ground can absorb heat rejected from a
condenser of M-AC. The coefficient of performance (COP) of C-AC
was about 2.5 whereas those of M-AC were found to be higher. It
was found that the values of COP of M-AC with condensing coils of
67, 50 and 40 m long were about 6.9, 5.5 and 3.3, respectively, while
that of 30-m-long one was found to be about 2.1. The electrical
consumptions of M-AC were found lower than that of C-AC in the
range of 11.5 – 15.5%. Additionally, life expectancy of underground
condensing coil of M-AC was found to be over 7 years.
Abstract: Silicon nanowire (SiNW) based thermoelectric device (TED) has potential applications in areas such as chip level cooling/ energy harvesting. It is a great challenge however, to assemble an efficient device with these SiNW. The presence of parasitic in the form of interfacial electrical resistance will have a significant impact on the performance of the TED. In this work, we explore the effect of the electrical contact resistance on the performance of a TED. Numerical simulations are performed on SiNW to investigate such effects on its cooling performance. Intrinsically, SiNW individually without the unwanted parasitic effect has excellent cooling power density. However, the cooling effect is undermined with the contribution of the electrical contact resistance.